Тәржемә мөхәррирләү
Эҙләргә

Сүс оптик кабель

Fiber Optic Cable Manufacturer — GYTS, GYTA, АДСС, ASU, Кәмеү, Air-Blown Micro & Submarine Cable

FIBCONET has manufactured fiber optic cable in China for 12 йылдар, running dedicated automated lines for stranded loose-tube, central-tube, self-supporting, air-blown micro and submarine cable series.

Combined output on our mainstream armored lines (GYTS / GYTA) reaches tens of millions of fiber-kilometers per year, with stock inventory maintained across 4–288-core standard configurations.

fiber optic cable structure

Every drum ships after 100% factory testing — attenuation, һуҙылыу, water penetration and end-of-drum OTDR trace — against МЭК 60794 series and other applicable standards. Our submarine cable also complies with ГБ/Т 18480, ITU-T G.976 and GJB 4489 military-grade specifications.

Below are the twelve cable series currently shipping to telecom operators, engineering contractors, power utilities and FTTH integrators across Southeast Asia, the Middle East, Latin America and Europe. Each product page carries fiber count options, connector-ready pre-termination, and full mechanical / environmental specifications.

Fiber Optic Cable Series We Manufacture

Тип кабель Модель Ҡуйылыу Max Fiber Count Key Highlight
Stranded Loose Tube, Steel-Tape Armored GYTS Ҡалын, авиация 288 сүстәре Long-term tensile 600 Н.; һәләк 300 N/100 mm; 20-year jacket life
Stranded Loose Tube, Aluminum-Tape Armored GYTA Ҡалын, авиация (PE conduit for direct burial) 288 сүстәре Anti-rodent, moisture-blocking, EMI-shielding; UV-additive option extends life +5 йылдар
Central Loose Tube, Non-Metallic GYXTY / GYFXY (FRP-reinforced) Авиация, каналы, lightning-prone regions 24 сүстәре Еңел, all-dielectric; jacket down to 1.1 мм; 10,000 км. / month output
Бөтә диэлектрик үҙ-үҙеңде тәьмин итеү (АДСС), Single-Jacket ADSS Single-Jacket Авиация, power-line corridors, spans up to 300 м 144 сүстәре Aramid strength member; PE jacket 1.8 mm ± 0.1 мм; 25–40% lower cost than double-jacket
АДСС, Double-Jacket ADSS Double-Jacket Aerial in coastal salt-fog, глазурь, long-span installations 288 (тиклем 576 custom) 10–15 years extended service life vs single-jacket; 720 h тоҙ-бөркөү һынауы; UV per GB/T 18899-2023
Aerial Self-Supporting (ASU) ASU / GYFXY-lightweight Short-span aerial & duct dual use, тиклем 120 м таралыу 24 сүстәре 3,000 h UV without cracking; 15-year warranty with 1:1 defect replacement; lower cost than ADSS
Figure-8 Central-Tube GYXTC8S Aerial with integral messenger, тиклем 100 м таралыу 96 сүстәре 7×1.2 galvanized steel strand messenger, 5 kN tensile; 30-year UV per IEC 60794-1
Air-Blown Micro Cable ГЦИФЙ / GCYFXY Microduct systems 144 сүстәре (stranded); 24 сүстәре (central-tube) Outer diameter from 1.8 мм; grooved jacket for extended blowing distance; HDPE or LSZH
FTTH Drop Cable, Bow-Type Self-Supporting ГХХЧЧ FTTH outdoor drop with steel or FRP messenger 1–4 fibers G.657.A2 default; steel-wire or non-metallic (ФРП) messenger; Лшж. / П.Э. / ПВХ курткаһы
FTTH Drop Cable, Indoor Bow-Type ГЖХХ FTTH indoor drop, ферма 1–4 fibers LSZH jacket standard; G.657.A2 bend-insensitive fiber
Өй эсендәге таратыу кабель GJFJV / tight-buffer Building risers, indoor cabling, patch cord raw stock 2–24 fibers 5 production lines × 180 km/day; long-term tensile 200 Н. (2.0 мм); operating −20 to +70 °C
Submarine Cable GYTA33 & deep-water armored Яр буйы, island interconnect, offshore platforms, deep-water up to 8,000 м 288 сүстәре 100 Gb/s unrepeated span up to 500 км.; long-term tensile 4 кН, short-term 10 кН; 25-year design life; meets GB/T 18480, МЭК 60794, ITU-T G.976 and GJB 4489

ОПГВ (Оптик ер сым) and photoelectric composite cable are also part of our line for power-utility deployments — see the OPGW product page for structural options and short-circuit current ratings.

fiber optic cable series

How to Choose the Right Fiber Optic Cable

Three questions determine the right cable for a project: where it’s installed, how many fibers it carries, һәм what mechanical / environmental loads it faces.

1. Match the Cable to the Deployment Environment

Deployment Environment Тәҡдим ителгән серия Нимәгә
Ҡалын / каналы (standard telecom trunk) GYTS or GYTA Бронетанный, high tensile, 20-йыл хеҙмәт итеү ваҡыты
Авиация, lightning-prone region GYFTY / GYXTY (металл булмаған) or ADSS All-dielectric prevents lightning damage
Aerial along power lines (spans > 100 м) ADSS Single-Jacket (temperate) or Double-Jacket (coastal / глазурь) Self-supporting up to 300 м; aramid-yarn strength
Direct burial GYTA53 (double-jacket + steel-tape armor) or GYTA + PE conduit Rodent, crush and moisture protection
Microduct (existing or new) Air-Blown Micro Cable (ГЦИФЙ / GCYFXY) 1.8 mm minimum diameter, groove jacket for blow distance
Short-span aerial + duct dual-use ASU Cheaper than ADSS, higher tensile than standard drop cable
Aerial with integral messenger, mid-span Figure-8 GYXTC8S Built-in steel messenger, 5 kN tensile, 100 м таралыу
FTTH outdoor drop GJYXCH bow-type self-supporting Steel or FRP messenger; G.657.A2 bend-insensitive fiber
FTTH indoor drop / ферма GJXH indoor bow-type LSZH jacket for building fire code
Яр буйы, island interconnect, offshore Submarine cable (GYTA33 series) HDPE jacket, galvanized or Zn-Al armored steel wires
Power utility ground wire ОПГВ Composite power ground + оптик кабель

2. Calculate the Fiber Count You Need

A working formula: total equipment ports × 2, plus a 10–20% spare buffer. For serial-multiplexed devices the count can be lower. Standard fiber counts we stock: 2, 4, 6, 8, 12, 24, 48, 96, 144, 288. Non-standard counts including 576-core (ADSS double-jacket) һорау буйынса бирелә.

3. Match Jacket and Armor to the Load Profile

  • Standard PE — general outdoor, 20-йыл хеҙмәт итеү ваҡыты
  • UV-additive PE — extends outdoor life by ~5 years for high-solar regions
  • А.Т. (анти-треклаштырыу) П.Э. — for ADSS installed near high-voltage lines to resist electrical corrosion
  • Лшж. — low smoke zero halogen for tunnels, метрополитендар, data centres and indoor riser
  • HDPE — submarine, high-crush and pressure environments
  • Steel-tape armor (GYTS) — rodent protection, еүешлек, EMI shielding
  • Aluminum-tape armor (GYTA) — equivalent protection, lower weight, better in some corrosive environments
  • 316L stainless steel armor — coastal / marine upgrade for figure-8 messenger; Zn-Al plated for corrosion

GYTS vs GYTA vs ADSS — Quick Comparison for Telecom Trunk Cabling

GYTS GYTA АДСС
Armor Corrugated steel tape Corrugated aluminum tape None (all-dielectric)
Көс ағзаһы Ҡорос сым . (FRP for lightning zones) Ҡорос сым . Арамид еп
Aerial span limit ~80 m ~80 m тиклем. 300 м
Direct burial PE conduit recommended PE conduit mandatory Ҡулланылмай
Иң яҡшыһы Standard duct / авиация, high-rodent risk Same as GYTS, lower weight Long-span aerial along power poles

Technical Specifications Across Trunk Cable Series

Параметр Байлыҡ
Fiber grade (иғтибарһыҙлыҡ) Г.652.Д (турала 90% of shipments); Г.657.А1., Г.657.А2., G.654.E and OM3 / OM4 / OM5 on request
Аттенюация @ 1310 нм ≤ 0.35 дБ/км
Аттенюация @ 1550 нм ≤ 0.21 дБ/км
Fiber count range 2 – 288 cores standard; тиклем 576 cores custom (ADSS double-jacket)
Минималь эйелеү радиусы ≥ 10× cable diameter (статик); ≥ 20× diameter (динамик)
Long-term tensile strength GYTS/GYTA 600 Н.; Figure-8 5 кН; Submarine 4 kN long-term / 10 kN installation
Ҡырҡыуға ҡаршы тороусанлыҡ ≥ 300 N/100 mm (armored series)
Эш температураһы −40 тиклем +70 °C (асыҡ һауала); −20 тиклем +70 °C (indoor LSZH / ПВК)
Design service life Outdoor armored 20 йылдар; ADSS double-jacket 25–30 years; һыу аҫты кәмәһе 25 йылдар
Һынау 100% drum-by-drum attenuation test; OTDR trace archived per drum

Submarine Cable — Our Deep-Water Line ⭐

Our submarine cable line targets short-haul unrepeated systems — island interconnect, offshore platform tie-in, coastal loops — where a single-span 100 Gb/s link up to 500 км. eliminates the cost of subsea repeaters, power feed and maintenance.

  • Depth rating: standard shallow-water build for up to 100 м (most common); deep-water build rated up to 8,000 м
  • Сүс иҫәбе: тиклем 288 сүстәре
  • Armor: shallow-water uses hot-dip galvanized low-carbon round steel wire; deep-water uses high-carbon high-tensile round steel wire with zinc-aluminum alloy coating
  • Куртка: HDPE for seawater corrosion, water blocking and pressure resistance
  • Tensile: оҙайлы 4 кН, short-term installation 10 кН
  • Стандарттар үтәү: ГБ/Т 18480, МЭК 60794, ITU-T G.976, GJB 4489
  • Design service life: кәм түгел 25 йылдар
  • Installation methods: trench burial (flat silt/sand seabed), surface laying (calm water), casing protection (rocky/reef zones), underwater suspension (bay spans)

Manufacturing Capability

Automated Production Lines with Inline Inspection

Our GYTS / GYTA lines run imported cabling machines, high-speed secondary coating equipment, and dual-layer co-extrusion jacket lines. Inline laser concentricity gauges and real-time OTDR scanners monitor every step. A three-stage water-blocking process controls excess fiber length, tape thermal bonding and jacket extrusion parameters through digital process control.

Annual Output & Stock Position

  • GYTS / GYTA: tens of millions of fiber-kilometers per year across all core counts, with 4–288-core standard configurations kept in stock
  • GYXTY: ~10,000 km per month
  • Indoor distribution cable: 5 production lines × 180 km per line per day
  • ADSS Single-Jacket: 12–48-core kept in stock; МОК 1 км.
  • ASU: 2–24-core standard in stock; same-day shipping for regular configurations
  • Figure-8: 2–48-core in stock across 4 dedicated extrusion lines

100% Drum-by-Drum Testing

  • Attenuation test on every drum before shipment — not sampling
  • Length tolerance strictly controlled within +1 тиклем +2 metres per drum
  • Per-drum OTDR trace archived and provided to buyer on request
  • Tensile, water-penetration and aging test reports available under IEC 60794 методикаһы

Container Loading & Ҡаплау

Standard drum length is 1–3 km per wooden reel for most trunk series; custom drum lengths supported on request. Approximate cable-length loading per container for figure-8 and similar profiles:

  • 20 GP container: 800 – 1,200 km of cable
  • 40 HQ container: 1,900 – 2,800 km of cable

Actual loading depends on cable diameter, drum size and stacking configuration — our sales team will calculate exact quantities against your PO.

Сертификациялау һәм ҡағиҙәләрҙе үтәү

  • ИСО 9001 Сифат менән идара итеү системаһы, завод киңлеге
  • МЭК 60794 series — optical cable performance, environmental and mechanical test methods
  • С.Э. — European conformity for applicable product lines
  • УЛ. / ЭТЛ — available for North American market entry
  • КПР — European Construction Products Regulation, for cables installed in permanent buildings
  • РоХС — hazardous substance compliance; certificates renewed annually
  • Submarine cable additionally complies with ГБ/Т 18480, ITU-T G.976 and GJB 4489

Сертификациялау ҡулланыу продукция линияһы һәм тәғәйенләнеш баҙары буйынса төрлөсә. Please confirm the target country, deployment environment and required standards when requesting a quotation.

Frequently Asked Questions About Fiber Optic Cable Sourcing

1-се һорау.. What is your minimum order quantity?

Standard trunk cable MOQ is 1 км.. Indoor distribution cable also 1 km MOQ; custom-colour indoor cable requires 5 км.. Submarine cable typically starts at 100 km due to the specialized production line setup. Bow-type drop cable ships from standard stock.

2-се һорау.. What is the standard lead time?

Regular 2–48-core GYTS / GYTA / GYXTY / ASU configurations ship from stock within days. Custom fiber counts, lengths or non-standard jackets: typically 15–25 working days depending on drum count. Submarine cable and 288-core+ builds require project-specific scheduling.

3-сө һорау.. Which fiber grade do you use as default?

Турала 90% of our finished cable ships with Г.652.Д single-mode fiber. G.657.A1 and G.657.A2 bend-insensitive grades are our default for drop cable and tight-space installations. G.654.E for long-haul 400G+ backbone and OM3 / OM4 / OM5 multimode for data-centre indoor cable are available on request.

Q4. Can you provide OTDR traces and test reports per drum?

Эйе. Every drum ships after 100% attenuation testing, with the OTDR trace archived. Written test reports covering tensile, water penetration and thermal aging are available under IEC 60794 methodology on request — useful for project acceptance and customs clearance.

5-се һорау.. Can you customize drum length, colour and marking?

Эйе. Standard drums are 1–3 km; longer runs supported on request (мәҫ.. ADSS in 500 м, 1200 m or segmented lengths). Jacket colour customization has a 5 km MOQ. Sequential metre marking, batch code and buyer logo can be printed to your specification.

faq

6-сы һорау.. What certifications can you supply for European and North American markets?

Our cable ships with ISO 9001, С.Э., RoHS and IEC 60794 compliance as standard. УЛ. / ETL certifications are supported for North American entry; CPR is available for cable installed in permanent European buildings. Third-party test reports and country-specific certification can be arranged per project.

7-се һорау.. How do I choose between GYTS, GYTA, GYFTY, ADSS and ASU?

Short answer: файҙаланыу GYTS or GYTA for standard duct / aerial trunk cabling; GYFTY when a non-metallic (unarmored) cable is required; ADSS single-jacket for aerial spans up to 300 m in temperate conditions, double-jacket for coastal salt-fog or ice-loaded spans; ASU for short-span aerial + duct dual-use where you want the strength of ADSS without the cost. Detailed matrix above.

8-се һорау.. Do you supply cables suitable for direct burial?

For direct burial we recommend GYTA53 (double-jacket with steel-tape armor) or GYTA with an additional PE protective conduit. Standard single-jacket ASU and ADSS are not designed for direct burial — the buried environment will corrode the jacket over time.

9-сы һорау.. What is the warranty and service life?

Стандарт завод гарантияһы 1000 тәшкил итә. 1 йыл. Design service life: 20 years for standard outdoor armored cable; 25–30 years for ADSS double-jacket and submarine cable; 15 years for ASU with 1:1 defect replacement if the failure is traced to manufacturing.

10-сы һорау. How much cable fits in a shipping container?

For figure-8 and similar profiles: а . 20 GP container carries approximately 800–1,200 km of cable; а . 40 HQ carries 1,900–2,800 km. Exact loading varies with cable OD, drum size and stacking. Provide us the drum spec and we’ll calculate loading before the PO is placed.

Тиҙ цитата алырға

Беҙ яуап бирәсәкбеҙ эсендә . 12 сәғәт, рәхим итеп, ялғау менән электрон почтаға иғтибар итегеҙ “@fibconet.com”..