If you’re building a private-label FTTH product line, this connector is OEM-ready from unit one.
Custom logo methods
MOQ OEM: 1,000 pcs. Custom printing +¥0.10/pc. Custom color bag and color box available upon request. If you need housing color changes, we discuss tooling and MOQ separately at project scope.
We also support mixed SKU orders — combine SC/APC and SC/UPC in the same purchase order to match your project mix or distributor stock plan.
El temps de lliurament depèn de la quantitat de la comanda, stock status and customization requirements. Stable production scheduling is available for repeat orders and project-based supply. Per a comandes urgents de projectes, la programació accelerada es pot discutir en l'etapa de RFQ.
Detalls del producte
Descripció general del producteFIBCONET SC APC/UPC fast connector solves two long-standing headaches for FTTH installers: batch-to-batch insertion loss drift, and endface contamination during field inspection. We machine the V-groove from one-piece 304 acer inoxidable, so the groove holds ±0.5 μm tolerance instead of the ±5 μm+ typical of injection-molded plastic. We mold the dust cap from transparent PC, so your field engineer inspects the ferrule endface by eye — cap closed, no dust ingress.
The connector supports single-mode FTTH deployments across ONT home termination, outdoor distribution boxes and ADSS aerial networks. If you supply FTTH projects in the Philippines, Vietnam, or Latin America, you already know the environment — high humidity, salt fog on coastal routes, dusty aerial spans, wide day-night temperature swings. This connector holds ±0.5 μm groove geometry from −40 °C to +85 °C and resists index-matching gel corrosion, so day-one performance is also year-five performance.
We produce housings in-house, test every unit for IL and RL before shipment, and support SC/APC + SC/UPC mixed SKU orders from stock. MOQ és 1,000 pcs. OEM logo, custom color bag and color box available.
If you’re a project contractor loading 5,000 fast connectors onto a truck for a rural FTTH build, you don’t want to find out at node 800 that this batch runs 0.15 dB hotter than the last one. El nostre 304 stainless steel V-groove is machined as one piece, tolerance held at ±0.5 μm. You get IL ≤0.3 dB on the first cold connection, every batch. We measure IL and RL on 100% of units before shipment.
You may be an ISP QA lead worried about dust ingress during field inspection. You may be a distributor whose local installers cut corners and forget to reclose caps. Or a foreman tired of rework tickets. Transparent PC dust caps let anyone verify ferrule cleanliness, scratches and cleave quality in about 2 seconds — by eye or with a pocket microscope. Cap stays closed. No airborne contamination. No reclose step to skip.
Installers make mistakes. Fiber gets cut too short, cable routing changes, someone drops a tool on the enclosure. With our metal V-groove, you re-terminate the same connector up to 10 times without slot collapse or groove deformation. Plastic V-groove connectors give you one shot, then straight into the bin. Over a project bill of materials, this is real consumable savings.
Index-matching gel softens plastic V-grooves over time. Humid air pushes plastic components toward creep. High-temperature aerial spans over metal ADSS cable make it worse. El nostre 304 stainless steel groove doesn’t corrode, doesn’t swell, doesn’t creep. The operating range is −40 °C to +85 °C — verified across the temperature cycle. Year-five insertion loss reads the same as year-one.
The housing carries a built-in triple-lock retention mechanism. Once you assemble the connector properly, it doesn’t loosen under vibration, doesn’t slip off during rough handling in the drop cable enclosure, doesn’t come apart when the installer wraps the cable back around a hook. You reduce warranty callbacks. Distributors reduce return volume.
| Paràmetre | SC/APC | SC/UPC |
|---|---|---|
| Tipus de connector | SC/APC | SC/UPC |
| Pèrdua d'inserció | ≤0,3 dB | ≤0,3 dB |
| Pèrdua de retorn | ≥55 dB | ≥50 dB |
| V-Groove Material | 304 Acer inoxidable (one-piece machined) | 304 Acer inoxidable (one-piece machined) |
| V-Groove Precision | ±0,5 μm | ±0,5 μm |
| Tapa antipols | Transparent PC | Transparent PC |
| Habitatge | PC Alloy | PC Alloy |
| Boot | Niló | Niló |
| Temperatura de funcionament | −40 °C ~ +85 °C | −40 °C ~ +85 °C |
| Reutilització | ≥10 re-terminations | ≥10 re-terminations |
| Retention Structure | Triple-lock anti-slip | Triple-lock anti-slip |
| Compatibilitat de fibra | Monomode, to be confirmed according to fiber standard requirement | Monomode, to be confirmed according to fiber standard requirement |
| Cable aplicable | Drop cable and round cable, specification to be confirmed by project requirement | Drop cable and round cable, specification to be confirmed by project requirement |
| Disseny de vida útil | ≥5 years typical | ≥5 years typical |
| Prova | 100% EL / RL provat abans del lliurament | 100% EL / RL provat abans del lliurament |
| MOQ | 1,000 pcs | 1,000 pcs |
| Standard Packaging | 1 pc/polybag, 100 pcs/carton mailer box | 1 pc/polybag, 100 pcs/carton mailer box |
| Opcions OEM | Silkscreen / Laser engraving / Mold embossing | Silkscreen / Laser engraving / Mold embossing |
| Mostra | Disponible a petició | Disponible a petició |


Every FTTH deployment in a dusty or humid environment shares the same field problem: how do you inspect the ferrule endface without exposing it to the environment you’re trying to protect it from?
Standard opaque-cap fast connectors force a three-step ritual — open the cap, inspect (or clean and inspect), reclose. In a windy aerial span or a roadside distribution box, that middle step is when contamination lands on the endface. Field data across FTTH deployments consistently shows dust ingress during inspection is a leading cause of avoidable rework.
Transparent PC dust caps replace that ritual with a single visual check. The installer holds the connector up, looks through the cap, verifies the ferrule is clean and the cleave is flat. Sota 2 segons. Cap never opens. If contamination is present, the installer knows before mating. If it’s clean, the connector goes straight into service.
For distributors, this design also means fewer “the connector was dirty out of the box” complaints from local buyers — because the buyer can see the endface without opening anything.
The V-groove is the fiber alignment reference of any field-installable fast connector. Groove tolerance defines batch-to-batch insertion loss stability, long-term optical performance, and how many field re-terminations the connector survives.
| Punt de comparació | El nostre 304 Ranura en V d'acer inoxidable | Conventional Plastic V-Groove |
|---|---|---|
| Groove tolerance | ±0,5 μm | Típicament >±5 μm |
| Batch IL stability | Estable, ≤0.3 dB one-shot | Fluctuates batch to batch |
| Reutilització | ≥10 re-terminations, no slot collapse | Single-use only; groove deforms |
| Gel resistance | Metal — no corrosion, no swelling | Plastic softens on long-term gel contact |
| Temperature stability | −40 °C a +85 °C, geometry stable | Summer creep, winter contraction |
| Service life | ≥5 years typical | 2–3 years typical |
Plastic V-grooves work fine for indoor test environments and low-cycle patchwork. They are not the right choice for outdoor FTTH aerial spans, coastal distribution boxes, or any deployment where the connector spends multi-year service under matching gel, temperature swings and humidity.
Informació de la paraula
FIBCONET operates in-house injection molding and an on-site IL/RL test station. Every fast connector unit is measured for insertion loss and return loss before it leaves the factory — not sample-batch, but 100% test coverage. Housing production is fully in-house, so mold-to-mold consistency is under our own quality system.
Batch documentation is available for project buyers who need it for acceptance or tender submission. Test reports and specification confirmation should be discussed with our sales team at RFQ stage, and reports can be issued according to product batch and project requirement.
Certificates such as RoHS, CE and ISO 9001 may be available at company system level or product category level; please confirm the specific document requirement for your customs, tender or project use before ordering.

FTTH Home Termination (ONT side) Quick plug-and-play at the ONT. No field polishing, no epoxy, no cure time. One-click cold connection. Suited for high-volume last-mile subscriber activation in urban Philippines and Vietnam FTTH rollouts.
Outdoor Distribution Box IP-rated enclosure deployments in tropical humidity, coastal salt-fog and rural aerial cabinets. Operating range −40 °C to +85 °C, no performance drift over multi-year service. Widely deployed across FTTH access networks in the Philippines and Latin America.
ADSS Aerial FTTx Network Self-supporting aerial cable spans across mountain and rural last-mile routes. Wind-load rated. Stainless steel groove holds geometry through daily thermal cycles typical of tropical aerial installations.

Both versions share the same 304 ranura en V d'acer inoxidable, transparent PC dust cap, PC alloy housing and −40 °C to +85 °C operating range. The optical difference is polish geometry: SC/APC delivers return loss ≥55 dB (typical for GPON / EPON), SC/UPC delivers return loss ≥50 dB (typical for Ethernet / general single-mode links). Insertion loss is ≤0.3 dB for both.
Sí. Les comandes de SKU mixtes s'admeten des de l'estoc. Tell us the split at RFQ stage — for example 3,000 pcs APC + 2,000 pcs UPC — and we scale packaging cartons accordingly.
MOQ és 1,000 pcs per SKU. Sample orders are available for buyers evaluating batch quality before bulk ordering. Talk to our sales team for sample terms and lead time.
Field engineers can inspect the ferrule endface — checking for dust, scratches or cleave imperfections — without opening the cap. This cuts inspection time to about 2 seconds per unit and eliminates the airborne dust ingress risk of opening the cap in outdoor sites. For dusty aerial spans and tropical outdoor distribution boxes, this design meaningfully reduces field rework.
El 304 stainless steel V-groove holds up to ≥10 re-terminations without slot deformation or groove collapse. This is a real project-cost saving over plastic V-groove connectors, which are effectively single-use.
Designed for single-mode FTTH deployments. Exact fiber standard compatibility (G.652D / G.657A1 / G.657A2) and applicable cable specifications (cable de baixada, round cable diameter) should be confirmed against your project requirement before bulk ordering.
Sí. El 304 stainless steel V-groove does not corrode or swell in long-term contact with index-matching gel, and the operating range is −40 °C to +85 °C. Deployed across FTTH networks in the Philippines, Vietnam and coastal Latin America.
Sí. Silkscreen, laser engraving and mold embossing are all available on the housing. Custom color bags and color boxes are supported. OEM MOQ és 1,000 pcs; custom printing adds ¥0.10/pc. For housing color changes, discuss tooling separately.
100% IL and RL testing is performed on every unit before shipment. Batch-level test documentation can be issued according to project or acceptance requirement — please confirm document format at RFQ stage.
Compliance documents such as RoHS, CE and ISO 9001 may be available at company system level or product category level. Si us plau, confirmeu el certificat específic que necessiteu per a les vostres duanes, tender or project use before ordering.
Standard packaging is 1 pc per individual polybag, 100 pcs per corrugated mailer box. Custom color bags, color boxes and retail-ready packaging are supported for private-label distributors.
El temps de lliurament depèn de la quantitat, estat de l'estoc i personalització. Stable production scheduling is available for repeat orders and project-based supply, and expedited scheduling can be discussed for urgent project orders.
Consulta de producte






Respondrem dins 12 hores, si us plau, pareu atenció al correu electrònic amb el sufix “@fibconet.com”.
També, pots anar al Pàgina de contacte, que proporciona una forma més detallada.
Els nostres experts en vendes respondran dins 24 hores, si us plau, pareu atenció al correu electrònic amb el sufix “@fibconet.com”.