MPO / MTP Data Center Cabling Manufacturer — Cassettes, Patch Panels, Trunk Cables and Patch Cords
Η Fibconet κατασκευάζει 10 series of MPO / MTP fiber optic products for 40G, 100σολ, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.

Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 κομμάτια across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 dB on assemblies built with Japanese-imported ferrules, and to typical 0.20–0.35 dB on standard builds with domestic Sanhuan ferrules.

Every finished cable is 100% inspected for insertion loss, απώλεια επιστροφής, end-face geometry, πόλωση, ακολουθία ινών, μήκος και εμφάνιση. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 MPO / MTP Products We Manufacture
Ομάδα 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.

Μοντέλο
Καταμέτρηση ινών
Διεπαφή
Τυπική χρήση

Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 προς την 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion

12/24 Μονάδα κασέτας MPO Solution υψηλής πυκνότητας πυρήνα
12 ή 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base

8/12/24 Βάση MTP MPO 24 LC ULTRA HIGH
Μέχρι και 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows

Ομάδα 2 — Rack Patch Panels
Empty or pre-assembled 1U 19-inch chassis to hold cassette modules and to organise trunk cables at the top of the rack.

Μοντέλο
Rack Size
Loading
Τυπική χρήση

Data Center 19-inch Standard Rack MPO Patch Panel
1U
Empty chassis for cassettes
Standard MDA rack, modular build

Pre-assembled 1U 19-inch Rack LC MTP®/MPO Patch Panel
1U
Pre-terminated LC front, MPO back
Plug-and-play rack, no field assembly

Ομάδα 3 — Patch Cords and Trunk Cables

The physical link between MPO cassettes, patch panels, transceivers and MPO backbone runs.

Μοντέλο
Δομή
Fiber Options
Τυπική χρήση

Factory Pre-termination MPO-MPO 3.0mm LSZH Patch Cord / Trunk Cable
MPO to MPO
OS2 / ΟΜ3 / ΟΜ4 / ΟΜ5
Backbone trunk, MDA to EDA

Καλώδιο μπαλώματος σύνδεσης MPO MTP οπτικών ινών
MPO to MPO
OS2 / ΟΜ3 / ΟΜ4 / ΟΜ5
Rack-to-rack short jumper

FTTA MPO/MTP Fiber Optic Patch Cord Cable
MPO to MPO, outdoor jacket
OS2 / ΟΜ3 / ΟΜ4
Base station FTTA and outdoor short link

Ομάδα 4 — Loopback
Used to test transceiver ports, cassette continuity and rack integrity without pulling a full trunk link.

Μοντέλο
Διεπαφή
Ινα
Τυπική χρήση

OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
OM3 multimode
Multimode transceiver and cassette test

Ομάδα 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.

Μοντέλο
Ταιριάζει
Τυπική χρήση

Όλοι οι τύποι που ταιριάζουν στο καθαριστικό MPO/MTP
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit

What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
MPO (Multi-fiber Push On) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Both mate with each other and both follow the same fiber count and polarity rules. Fibconet manufactures to the MPO standard and supplies MTP-compatible builds on request; the underlying optical spec is identical.
Polarity — Type A, Τύπος Β, Τύπος Γ

Πόλωση
Fiber Sequence
Τυπική χρήση

Τύπος Α (Ευθεία)
1↔1, 2↔2 … 12↔12 straight-through
Point-to-point trunks with A-to-B duplex crossover in the patch cord

Τύπος Β (Reverse)
1↔12, 2↔11 … 12↔1 fully reversed
Direct connection to SFP+ / QSFP transceivers; most common for 40G/100G breakout

Τύπος Γ (Pair-swap)
Adjacent pairs swapped: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling

Polarity errors are the single most common cause of link-up failure on MPO systems. Confirm polarity at RFQ stage; we ship Type A / σι / C per your bill of materials.
Gender — Male (with pins) vs Female (χωρίς καρφίτσες)

Αρσενικός: two guide pins protrude from the end-face. Used at fixed / patch-panel ends.
Female: χωρίς καρφίτσες, two guide-pin holes only. Used at the equipment / movable-jumper end.

Wrong gender at RFQ = the entire batch has to be re-terminated. Always specify Male-Female, Female-Female or Male-Male at the quotation stage.
Fiber Type — Match to Data Rate and Distance

Ινα
Μήκος κύματος
10G reach
40σολ / 100G reach
Τυπική χρήση

OM3 multimode
850 nm
550 Μ
100 Μ / 100 Μ (SR4)
Short rack-to-rack, cost-sensitive builds

OM4 multimode
850 nm
550 Μ
150 Μ / 150 Μ (SR4)
Standard data-center backbone

OM5 multimode
850 & 953 nm SWDM
550 Μ
≥ 150 Μ; supports 400G SR4.2
AI cluster and next-gen supercompute backbone

OS2 singlemode
1310 / 1550 nm
10 χλμ +
10 χλμ + (LR4 / DR4)
Inter-building, campus, DCI long-haul

Insertion Loss Grade — Standard vs Low-Loss

Βαθμός
Max IL per mated pair
Απώλεια επιστροφής
Τυπική χρήση

Πρότυπο (SM APC)
≤ 0.70 dB
≥ 55 dB
Enterprise LAN, standard data-center runs

Low-Loss / Αφρόκρεμα (SM APC)
≤ 0.35 dB (τυπικός 0.25 dB)
≥ 55 dB
Cabinet-to-cabinet 100G high-density backbone

Ultra Low-Loss (Japanese ferrule)
0.15 dB per single fiber
≥ 55 dB
400σολ / 800G AI backbone; long link budgets

Πρότυπο (MM PC)
≤ 0.50 dB
≥ 20 dB
OM3/OM4 short data-center runs

Low-Loss (MM PC)
≤ 0.35 dB (τυπικός 0.20 dB)
≥ 20 dB
OM4/OM5 high-density backbone

Τεχνικές προδιαγραφές

Σημείωση: the values below are family-typical across the 10 σειρά, όχι ένα φύλλο δεδομένων ενός SKU. Ζητήστε μας την αναφορά δοκιμής για το συγκεκριμένο μοντέλο στο στάδιο RFQ; το στέλνουμε κάτω από τον αριθμό ανταλλακτικού μοντέλου.

Παράμετρος
Τυπική αξία
Σχόλιο

Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone

Τύπος ινών
OS2 (Γ.652.Δ, G.657.A1/A2), ΟΜ3, ΟΜ4, ΟΜ5
G.657.A2 for tight-radius rack routing

Πόλωση
Τύπος Α / Τύπος Β / Τύπος Γ
Type B is default for 40G/100G breakout

Γένος
Αρσενικός (with pins) / Female (χωρίς καρφίτσες)
Both ends selectable per port

End-face polish
APC (single mode) / Η/Υ (πολυλειτουργικό)
APC green, PC beige/aqua

Απώλεια εισαγωγής (μονή ίνα)
0.15 – 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules

Απώλεια επιστροφής
≥ 55 dB (SM APC), ≥ 45 dB (SM PC), ≥ 20 dB (MM PC)

Αντοχή στο ζευγάρωμα
≥ 500 κύκλους, IL drift ≤ 0.2 dB
Guide-pin positioning with elastic pre-load

Ελάχιστη ακτίνα κάμψης
MPO end ≥ 30 mm; LC breakout end ≥ 20 mm
Στατικός 15 mm, δυναμικός 30 mm on G.657.A2 fiber

Θερμοκρασία λειτουργίας
−20°C to +60°C
Optical performance stable across the range

Ingress / υγρασία
IP50; 45°C / 95% RH; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed

Length range
0.2 προς την 300 m custom; · Συμβατό τόσο με καλώδιο πτώσης 3mm όσο και με επίπεδο καλώδιο 3x2mm · Γρήγορη και εύκολη εγκατάσταση 0.5 προς την 30 Μ
Ανά μοντέλο

Trunk cable OD
3.0 mm τυπικό (8/12/16/24φά); ~5.0 mm (48φά)
Higher fiber count = larger OD

Σακάκι
LSZH standard; OFNR / OFNP on request
Suitable for data hall, riser and plenum

Test wavelength
1310 / 1550 nm (SM), 850 / 1300 nm (ΜΜ)

Εγγύηση
1 έτος; design life up to 10 χρόνια
Field replacement covered within warranty period

Κατασκευαστική ικανότητα και ποιοτικός έλεγχος
Production Line and Monthly Capacity
Η μητρική λειτουργία της Fibconet σε οπτικά παθητικά εξαρτήματα χρονολογείται από το 1994. Το MPO / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 κομμάτια. Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
Έλεγχος υλικών ανάντη
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. Ελέγχουμε τη στοίβα ανάντη και όχι μόνο το βήμα συναρμολόγησης:

Σιδηράδες: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
Ινα: YOFC / Fiberhome / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
Αραμιδικό νήμα: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.

100% Επιθεώρηση ποιότητας

Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
Polarity and fiber sequence: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.

Πιστοποιήσεις και Συμμόρφωση
Το Fibconet λειτουργεί υπό ένα ενσωματωμένο ISO 9001 / ISO 14001 / ISO 45001 σύστημα διαχείρισης που καλύπτει την ποιότητα, περιβάλλοντος και υγείας στην εργασία & ασφάλεια. Raw-material RoHS reports ship by default. Product-level compliance — CE, ΕΚΤΑΣΗ, ο, ETL — is issued per model and per target market. Η δυνατότητα εφαρμογής πιστοποίησης ποικίλλει ανάλογα με τις απαιτήσεις προϊόντος και έργου. Στείλτε μας την αγορά-στόχο σας και τη λίστα μοντέλων; we return the applicable certificate set with the quotation.
Συσκευασία, OEM και προσαρμοσμένες επιλογές
Τυπική συσκευασία

Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, ποσότητα, polarity and gender code.

OEM και προσαρμοσμένες επιλογές

Μήκος: any length from 0.2 m to 300 Μ, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 εκ) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3×8 / 4×6; 16F to 2×8; 48F to 6×8; μέχρι και 6 MPO connectors per single end on MPO-to-MPO breakouts.
Πόλωση: Τύπος Α / σι / C per port; internal crossover on Type B for direct SFP mating.
Ferrule grade: domestic Sanhuan or Japanese-imported per fiber-count / IL grade selection.
Jacket color: aqua (ΟΜ3), erika violet (ΟΜ4), πράσινο ασβέστη (ΟΜ5), κίτρινος (OS2), custom RAL.
Breakout root protection: κανένας (short runs), nylon boot (standard rack), braided sleeve (high-wear).
OEM label and printing: on connector body, PE bag and master carton.
Προσαρμοσμένη συσκευασία: PE bag and carton design per your artwork, MOQ 30,000 pcs for full custom packaging run.
Δείγματα: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.

Συχνές Ερωτήσεις
Q1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Ε2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100σολ, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Ε3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100σολ / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / SC / FC on the other?
Ναί. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
Q5. Are both ends symmetric on MPO-to-MPO breakout cables?
Ναί. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. Μέχρι και 6 MPO connectors per single end are supported.
Ε6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100GSR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; we ship Type A / σι / C per your bill of materials.
Ε7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 dB. Ultra low-loss builds with Japanese ferrules reach 0.15 dB per single fiber. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
Ε8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
Ναί. Every cable and every fiber core is tested for insertion loss, απώλεια επιστροφής, end-face geometry, πόλωση, ακολουθία ινών, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
Ε9. Can I get samples before placing a bulk order?
Ναί. Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
Q10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 κομμάτια. Standard orders of several thousand pieces ship in 7–12 days from stock. Bulk orders above 20,000 pieces ship in 15–20 days. Custom packaging with full artwork runs from an MOQ of 30,000 τεμ.
Ε11. Can these MPO products be used outdoors?
The standard MPO line is optimised for data hall, MDA and rack environments (IP50, −20°C to +60°C, LSZH). For outdoor and FTTA applications, use the FTTA MPO/MTP Fiber Optic Patch Cord with an outdoor jacket, or ask for a custom outdoor build. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. Ποια είναι η εγγύηση?
Standard warranty is 1 έτος; design service life is up to 10 χρόνια. Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.