MPO / MTP Data Center Cabling Manufacturer — Cassettes, Patch Panels, Trunk Cables and Patch Cords
Fibconet toodab 10 series of MPO / MTP fiber optic products for 40G, 100G, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.
Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 tükid across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 dB on assemblies built with Japanese-imported ferrules, and to typical 0.20–0.35 dB on standard builds with domestic Sanhuan ferrules.
Every finished cable is 100% inspected for insertion loss, tagastamise kaotus, end-face geometry, polaarsus, kiudude järjestus, pikkus ja välimus. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 MPO / MTP Products We Manufacture
Grupp 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.
Mudel
Kiudude arv
Liides
Tüüpiline kasutus
Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 juurde 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion
12/24 Suure tihedusega põhilahendusega MPO kassetimoodul
12 või 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base
8/12/24 MPO MTP alus 24 LC Ultra kõrge tihedusega 1U moodul
Kuni 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows
Grupp 2 — Rack Patch Panels
Empty or pre-assembled 1U 19-inch chassis to hold cassette modules and to organise trunk cables at the top of the rack.
Mudel
Rack Size
Loading
Tüüpiline kasutus
Data Center 19-inch Standard Rack MPO Patch Panel
1U
Empty chassis for cassettes
Standard MDA rack, modular build
Pre-assembled 1U 19-inch Rack LC MTP®/MPO Patch Panel
1U
Pre-terminated LC front, MPO back
Plug-and-play rack, no field assembly
Grupp 3 — Patch Cords and Trunk Cables
The physical link between MPO cassettes, patch paneelid, transceivers and MPO backbone runs.
Mudel
Struktuur
Fiber Options
Tüüpiline kasutus
Factory Pre-termination MPO-MPO 3.0mm LSZH Patch Cord / Trunk Cable
MPO to MPO
OS2 / OM3 / OM4 / OM5
Backbone trunk, MDA to EDA
Fiiberoptiline MPO MTP-pistiku patchjuhe
MPO to MPO
OS2 / OM3 / OM4 / OM5
Rack-to-rack short jumper
FTTA MPO/MTP Fiber Optic Patch Cord Cable
MPO to MPO, outdoor jacket
OS2 / OM3 / OM4
Base station FTTA and outdoor short link
Grupp 4 — Loopback
Used to test transceiver ports, cassette continuity and rack integrity without pulling a full trunk link.
Mudel
Liides
Fiber
Tüüpiline kasutus
OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
OM3 multirežiim
Multimode transceiver and cassette test
Grupp 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.
Mudel
Sobima
Tüüpiline kasutus
Kõik tüübid sobivad MPO/MTP puhastusvahendiks
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit
What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
MPO (Multi-fiber Push On) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Both mate with each other and both follow the same fiber count and polarity rules. Fibconet manufactures to the MPO standard and supplies MTP-compatible builds on request; the underlying optical spec is identical.
Polarity — Type A, Tüüp B, Tüüp C
Polaarsus
Fiber Sequence
Tüüpiline kasutus
Tüüp A (Otsekohene)
1↔1, 2↔2 … 12↔12 straight-through
Point-to-point trunks with A-to-B duplex crossover in the patch cord
Tüüp B (Reverse)
1↔12, 2↔11 … 12↔1 fully reversed
Direct connection to SFP+ / QSFP transceivers; most common for 40G/100G breakout
Tüüp C (Pair-swap)
Adjacent pairs swapped: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling
Polarity errors are the single most common cause of link-up failure on MPO systems. Confirm polarity at RFQ stage; we ship Type A / B / C per your bill of materials.
Gender — Male (with pins) vs Female (nööpnõelad puuduvad)
Mees: otsapinnast ulatuvad välja kaks juhttihvti. Kasutatud fikseeritud / patch-paneeli otsad.
Naine: nööpnõelad puuduvad, ainult kaks juhttihvti auku. Varustuses kasutatud / liigutatav-hüppaja ots.
Vale sugu pakkumisel = kogu partii tuleb uuesti lõpetada. Määrake alati Mees-Naine, Naine-naine või mees-mees pakkumise etapis.
Kiudude tüüp – vastavus andmeedastuskiirusele ja kaugusele
Fiber
Lainepikkus
10G ulatus
40G / 100G ulatus
Tüüpiline kasutus
OM3 multirežiim
850 nm
550 m
100 m / 100 m (SR4)
Lühike riiulist riiulisse, kulutundlikud konstruktsioonid
OM4 multirežiim
850 nm
550 m
150 m / 150 m (SR4)
Standardne andmekeskuse magistraal
OM5 multirežiim
850 & 953 nm SWDM
550 m
≥ 150 m; toetab 400G SR4.2
AI klaster ja järgmise põlvkonna superarvuti magistraal
OS2 üherežiimiline
1310 / 1550 nm
10 km +
10 km + (LR4 / DR4)
Hoonetevaheline, ülikoolilinnak, DCI pikamaa
Sisestuskao hinne – standardne vs madala kaoga
Hinne
Max IL paaritatud paari kohta
Tagastamise kaotus
Tüüpiline kasutus
Standard (SM APC)
≤ 0.70 dB
≥ 55 dB
Ettevõtte LAN, standardsed andmekeskused
Madala kaotusega / Eliit (SM APC)
≤ 0.35 dB (tüüpiline 0.25 dB)
≥ 55 dB
Kapist-kappi 100G suure tihedusega selgroog
Ultra Low Loss (Jaapani ümbris)
0.15 dB ühe kiu kohta
≥ 55 dB
400G / 800G AI selgroog; pikad lingieelarved
Standard (MM arvuti)
≤ 0.50 dB
≥ 20 dB
OM3/OM4 lühike andmekeskus töötab
Madala kaotusega (MM arvuti)
≤ 0.35 dB (tüüpiline 0.20 dB)
≥ 20 dB
OM4/OM5 high-density backbone
Tehnilised kirjeldused
Märge: the values below are family-typical across the 10 seeria, mitte ühe SKU andmeleht. Küsige meilt mudelispetsiifilist testiaruannet RFQ etapis; saadame selle mudeli osa numbri all.
Parameeter
Tüüpiline väärtus
kommenteerida
Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone
Kiu tüüp
OS2 (G.652.D, G.657.A1/A2), OM3, OM4, OM5
G.657.A2 for tight-radius rack routing
Polaarsus
Tüüp A / Tüüp B / Tüüp C
Type B is default for 40G/100G breakout
Sugu
Mees (with pins) / Naine (nööpnõelad puuduvad)
Both ends selectable per port
End-face polish
APC (üherežiimiline) / PC (mitmerežiimiline)
APC green, PC beige/aqua
Sisestamise kaotus (üksikkiu)
0.15 – 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules
Tootmiskaotus
≥ 55 dB (SM APC), ≥ 45 dB (SM PC), ≥ 20 dB (MM arvuti)
Paaritumiskindlus
≥ 500 tsüklid, IL drift ≤ 0.2 dB
Guide-pin positioning with elastic pre-load
Minimaalne painderaadius
MPO end ≥ 30 mm; LC breakout end ≥ 20 mm
Staatiline 15 mm, dünaamiline 30 mm on G.657.A2 fiber
Töötemperatuur
−20°C to +60°C
Optical performance stable across the range
Ingress / niiskus
IP50; 45°C / 95% RH; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed
Length range
0.2 juurde 300 m custom; · Lihtne kokku panna mehaanilise ühendusliistuga ja pole poleerimist · Minimeerige defektide esinemissagedus eemaldamise ja korduvkasutatavate funktsioonide abil 0.5 juurde 30 m
Mudeli kohta
Trunk cable OD
3.0 mm typical (8/12/16/24F); ~5.0 mm (48F)
Higher fiber count = larger OD
Jope
LSZH standard; OFNR / OFNP on request
Suitable for data hall, riser and plenum
Katselainepikkus
1310 / 1550 nm (SM), 850 / 1300 nm (MM)
Garantii
1 aastal; design life up to 10 aastat
Field replacement covered within warranty period
Tootmisvõime ja kvaliteedikontroll
Production Line and Monthly Capacity
Fibconet’s parent operation in optical passive components dates back to 1994. MPO / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 tükid. Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
Ülesvoolu materjalikontroll
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. Me juhime pigem ülesvoolu virna kui ainult kokkupanekuetappi:
Höövlid: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
Fiber: YOFC / Fiberhome / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
Aramiidlõng: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.
100% Quality Inspection
Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
Polaarsus ja kiudude järjestus: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.
Sertifikaadid ja vastavus
Fibconet töötab integreeritud süsteemi all ISO 9001 / ISO 14001 / ISO 45001 kvaliteeti hõlmav juhtimissüsteem, keskkond ja töötervishoid & ohutus. Raw-material RoHS reports ship by default. Product-level compliance — CE, REACH, a, ETL — is issued per model and per target market. Sertifikaadi rakendatavus erineb olenevalt toote- ja projektinõuetest. Saatke meile oma sihtturg ja mudelite loend; we return the applicable certificate set with the quotation.
Pakendamine, OEM- ja kohandatud valikud
Standard Packaging
Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, kogus, polarity and gender code.
OEM- ja kohandatud valikud
Pikkus: any length from 0.2 m kuni 300 m, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 cm) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3×8 / 4×6; 16F to 2×8; 48F to 6×8; kuni 6 MPO connectors per single end on MPO-to-MPO breakouts.
Polaarsus: Tüüp A / B / C per port; internal crossover on Type B for direct SFP mating.
Ferrule grade: domestic Sanhuan or Japanese-imported per fiber-count / IL grade selection.
Jacket color: aqua (OM3), erika violet (OM4), laimiroheline (OM5), kollane (OS2), custom RAL.
Breakout root protection: mitte ühtegi (short runs), nylon boot (standard rack), braided sleeve (high-wear).
OEM label and printing: on connector body, PE bag and master carton.
Kohandatud pakend: PE bag and carton design per your artwork, MOQ 30,000 pcs for full custom packaging run.
Näidised: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.
Korduma kippuvad küsimused
Q1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Q2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100G, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Q3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100G / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / SC / FC on the other?
Jah. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
K5. Are both ends symmetric on MPO-to-MPO breakout cables?
Jah. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. Kuni 6 MPO connectors per single end are supported.
K6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100GSR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; we ship Type A / B / C per your bill of materials.
K7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 dB. Ultra low-loss builds with Japanese ferrules reach 0.15 dB ühe kiu kohta. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
Q8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
Jah. Every cable and every fiber core is tested for insertion loss, tagastamise kaotus, end-face geometry, polaarsus, kiudude järjestus, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
K9. Can I get samples before placing a bulk order?
Jah. Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
K10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 tükid. Standard orders of several thousand pieces ship in 7–12 days from stock. Bulk orders above 20,000 pieces ship in 15–20 days. Custom packaging with full artwork runs from an MOQ of 30,000 tk.
K11. Can these MPO products be used outdoors?
The standard MPO line is optimised for data hall, MDA and rack environments (IP50, −20°C to +60°C, LSZH). For outdoor and FTTA applications, use the FTTA MPO/MTP Fiber Optic Patch Cord with an outdoor jacket, or ask for a custom outdoor build. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. Mis on garantii?
Standard warranty is 1 aastal; design service life is up to 10 aastat. Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.
Vastame aja jooksul 12 tundi, pöörake tähelepanu järelliitega meilile "@fibconet.com".
Samuti, võite minna Kontakti leht, mis annab üksikasjalikuma vormi.