ویرایش ترجمه
جستجو کردن

سری MPO

MPO / MTP Data Center Cabling Manufacturer — Cassettes, پچ پنل ها, Trunk Cables and Patch Cords
Fibconet تولید می کند 10 series of MPO / MTP fiber optic products for 40G, 100جی, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.

Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 قطعات across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 دسی بل on assemblies built with Japanese-imported ferrules, and to typical 0.20–0.35 dB on standard builds with domestic Sanhuan ferrules.

Every finished cable is 100% inspected for insertion loss, برگشت ضرر, end-face geometry, قطبیت, دنباله فیبر, طول و ظاهر. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 MPO / MTP Products We Manufacture
گروه 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.

مدل
تعداد فیبر
رابط
استفاده معمولی

Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 به 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion

12/24 ماژول کاست MPO با چگالی بالا هسته هسته
12 یا 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base

8/12/24 پایه MPO MTP به 24 LC فوق العاده بالا چگالی 1U مدولار
تا 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows

گروه 2 — Rack Patch Panels
Empty or pre-assembled 1U 19-inch chassis to hold cassette modules and to organise trunk cables at the top of the rack.

مدل
Rack Size
Loading
استفاده معمولی

Data Center 19-inch Standard Rack MPO Patch Panel
1U
Empty chassis for cassettes
Standard MDA rack, modular build

Pre-assembled 1U 19-inch Rack LC MTP®/MPO Patch Panel
1U
Pre-terminated LC front, MPO back
Plug-and-play rack, no field assembly

گروه 3 — Patch Cords and Trunk Cables

The physical link between MPO cassettes, پچ پنل ها, transceivers and MPO backbone runs.

مدل
ساختار
Fiber Options
استفاده معمولی

Factory Pre-termination MPO-MPO 3.0mm LSZH Patch Cord / Trunk Cable
MPO to MPO
OS2 / OM3 / OM4 / OM5
Backbone trunk, MDA to EDA

وصله سیم اتصال فیبر نوری MPO MTP
MPO to MPO
OS2 / OM3 / OM4 / OM5
Rack-to-rack short jumper

FTTA MPO/MTP Fiber Optic Patch Cord Cable
MPO to MPO, outdoor jacket
OS2 / OM3 / OM4
Base station FTTA and outdoor short link

گروه 4 — Loopback
Used to test transceiver ports, cassette continuity and rack integrity without pulling a full trunk link.

مدل
رابط
فیبر
استفاده معمولی

OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
چند حالته OM3
Multimode transceiver and cassette test

گروه 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.

مدل
مناسب است
استفاده معمولی

انواع تمیز کننده MPO/MTP فیتینگ
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit

What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
MPO (چند فیبر Push On) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Both mate with each other and both follow the same fiber count and polarity rules. Fibconet manufactures to the MPO standard and supplies MTP-compatible builds on request; the underlying optical spec is identical.
Polarity — Type A, نوع B, نوع C

قطبیت
Fiber Sequence
استفاده معمولی

نوع A (Straight)
1↔1, 2↔2 … 12↔12 straight-through
Point-to-point trunks with A-to-B duplex crossover in the patch cord

نوع B (Reverse)
1↔12, 2↔11 … 12↔1 fully reversed
Direct connection to SFP+ / QSFP transceivers; most common for 40G/100G breakout

نوع C (Pair-swap)
Adjacent pairs swapped: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling

Polarity errors are the single most common cause of link-up failure on MPO systems. Confirm polarity at RFQ stage; we ship Type A / ب / C per your bill of materials.
Gender — Male (with pins) vs Female (بدون پین)

مرد: two guide pins protrude from the end-face. Used at fixed / patch-panel ends.
Female: بدون پین, two guide-pin holes only. Used at the equipment / movable-jumper end.

Wrong gender at RFQ = the entire batch has to be re-terminated. Always specify Male-Female, Female-Female or Male-Male at the quotation stage.
Fiber Type — Match to Data Rate and Distance

فیبر
طول موج
10G reach
40جی / 100G reach
استفاده معمولی

چند حالته OM3
850 نانومتر
550 متر
100 متر / 100 متر (SR4)
Short rack-to-rack, cost-sensitive builds

OM4 multimode
850 نانومتر
550 متر
150 متر / 150 متر (SR4)
Standard data-center backbone

چند حالته OM5
850 & 953 nm SWDM
550 متر
≥ 150 متر; supports 400G SR4.2
AI cluster and next-gen supercompute backbone

OS2 singlemode
1310 / 1550 نانومتر
10 کیلومتر +
10 کیلومتر + (LR4 / DR4)
Inter-building, پردیس, DCI long-haul

Insertion Loss Grade — Standard vs Low-Loss

درجه
Max IL per mated pair
برگشت ضرر
استفاده معمولی

استاندارد (SM APC)
≤ 0.70 دسی بل
≥ 55 دسی بل
Enterprise LAN, standard data-center runs

Low-Loss / نخبه (SM APC)
≤ 0.35 دسی بل (معمولی 0.25 دسی بل)
≥ 55 دسی بل
Cabinet-to-cabinet 100G high-density backbone

Ultra Low-Loss (Japanese ferrule)
0.15 dB per single fiber
≥ 55 دسی بل
400جی / 800G AI backbone; long link budgets

استاندارد (MM PC)
≤ 0.50 دسی بل
≥ 20 دسی بل
OM3/OM4 short data-center runs

Low-Loss (MM PC)
≤ 0.35 دسی بل (معمولی 0.20 دسی بل)
≥ 20 دسی بل
OM4/OM5 high-density backbone

مشخصات فنی

توجه داشته باشید: the values below are family-typical across the 10 سری, نه یک دیتاشیت تک SKU. گزارش تست مدل خاص را در مرحله RFQ از ما بخواهید; ما آن را تحت شماره قطعه مدل ارسال می کنیم.

پارامتر
ارزش معمولی
اظهار نظر

Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone

نوع فیبر
OS2 (G.652.D, G.657.A1/A2), OM3, OM4, OM5
G.657.A2 for tight-radius rack routing

قطبیت
نوع A / نوع B / نوع C
Type B is default for 40G/100G breakout

جنسیت
مرد (with pins) / Female (بدون پین)
Both ends selectable per port

End-face polish
APC (تک حالته) / کامپیوتر (چند حالته)
APC green, PC beige/aqua

از دست دادن درج (تک فیبر)
0.15 – 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules

برگشت ضرر
≥ 55 دسی بل (SM APC), ≥ 45 دسی بل (SM PC), ≥ 20 دسی بل (MM PC)

دوام جفت گیری
≥ 500 چرخه ها, IL drift ≤ 0.2 دسی بل
Guide-pin positioning with elastic pre-load

حداقل شعاع خمش
MPO end ≥ 30 میلی متر; LC breakout end ≥ 20 میلی متر
استاتیک 15 میلی متر, پویا 30 mm on G.657.A2 fiber

دمای عملیاتی
−20°C to +60°C
Optical performance stable across the range

Ingress / رطوبت
IP50; 45درجه سانتی گراد / 95% RH; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed

Length range
0.2 به 300 m custom; تمام شاخص های نوری و مکانیکی با پچ کورد ملاقات می کنند 0.5 به 30 متر
در هر مدل

Trunk cable OD
3.0 mm typical (8/12/16/24اف); ~5.0 mm (48اف)
Higher fiber count = larger OD

ژاکت
LSZH standard; OFNR / OFNP on request
Suitable for data hall, riser and plenum

طول موج تست
1310 / 1550 نانومتر (اس ام), 850 / 1300 نانومتر (MM)

ضمانت
1 سال; design life up to 10 سال ها
Field replacement covered within warranty period

قابلیت تولید و کنترل کیفیت
Production Line and Monthly Capacity
قدمت عملیات والد Fibconet در اجزای غیرفعال نوری به قبل برمی‌گردد 1994. MPO / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 قطعات. Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
کنترل مواد بالادست
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. ما به جای مرحله مونتاژ، پشته بالادست را کنترل می کنیم:

لنگه: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
فیبر: YOFC / فیبرهوم / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
نخ آرامید: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.

100% بازرسی کیفیت

Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
قطبیت و توالی فیبر: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.

گواهینامه ها و انطباق
Fibconet تحت یکپارچه عمل می کند ISO 9001 / ISO 14001 / ISO 45001 سیستم مدیریت پوشش کیفیت, محیط زیست و بهداشت حرفه ای & ایمنی. Raw-material RoHS reports ship by default. Product-level compliance — CE, رسیدن, را, ETL — is issued per model and per target market. کاربرد گواهینامه بسته به الزامات محصول و پروژه متفاوت است. بازار هدف و لیست مدل خود را برای ما ارسال کنید; ما مجموعه گواهی قابل اجرا را با نقل قول برمی گردانیم.
بسته بندی, OEM و گزینه های سفارشی
بسته بندی استاندارد

Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, مقدار, polarity and gender code.

OEM و گزینه های سفارشی

طول: any length from 0.2 متر به 300 متر, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 سانتی متر) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3×8 / 4×6; 16F to 2×8; 48F to 6×8; تا 6 MPO connectors per single end on MPO-to-MPO breakouts.
قطبیت: نوع A / ب / C per port; internal crossover on Type B for direct SFP mating.
Ferrule grade: domestic Sanhuan or Japanese-imported per fiber-count / IL grade selection.
Jacket color: آبی (OM3), erika violet (OM4), سبز لیمویی (OM5), رنگ زرد (OS2), custom RAL.
Breakout root protection: هیچ یک (short runs), nylon boot (standard rack), braided sleeve (high-wear).
OEM label and printing: on connector body, PE bag and master carton.
بسته بندی سفارشی: PE bag and carton design per your artwork, MOQ 30,000 pcs for full custom packaging run.
نمونه ها: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.

سوالات متداول
Q1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Q2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100جی, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Q3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100جی / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / SC / FC on the other?
آره. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
Q5. Are both ends symmetric on MPO-to-MPO breakout cables?
آره. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. تا 6 MPO connectors per single end are supported.
Q6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100GSR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; we ship Type A / ب / C per your bill of materials.
Q7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 دسی بل. Ultra low-loss builds with Japanese ferrules reach 0.15 dB per single fiber. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
Q8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
آره. Every cable and every fiber core is tested for insertion loss, برگشت ضرر, end-face geometry, قطبیت, دنباله فیبر, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
Q9. Can I get samples before placing a bulk order?
آره. Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
Q10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 قطعات. Standard orders of several thousand pieces ship in 7–12 days from stock. Bulk orders above 20,000 pieces ship in 15–20 days. Custom packaging with full artwork runs from an MOQ of 30,000 عدد.
Q11. Can these MPO products be used outdoors?
The standard MPO line is optimised for data hall, MDA and rack environments (IP50, −20°C to +60°C, LSZH). For outdoor and FTTA applications, use the FTTA MPO/MTP Fiber Optic Patch Cord with an outdoor jacket, or ask for a custom outdoor build. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. What is the warranty?
Standard warranty is 1 سال; design service life is up to 10 سال ها. Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.

یک نقل قول سریع دریافت کنید

ما در داخل پاسخ خواهیم داد 12 ساعت ها, لطفا به ایمیل با پسوند توجه کنید "@fibconet.com".

همچنین, می توانید به صفحه تماس, که فرم دقیق تری ارائه می دهد.