MPO / MTP Data Center Cabling Manufacturer — Cassettes, Patch Paneli, Trunk Cables and Patch Cords
Fibconet proizvodi 10 series of MPO / MTP fiber optic products for 40G, 100G, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.
Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 komada across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 dB on assemblies built with Japanese-imported ferrules, and to typical 0.20–0.35 dB on standard builds with domestic Sanhuan ferrules.
Every finished cable is 100% inspected for insertion loss, povratni gubitak, end-face geometry, polaritet, slijed vlakana, duljina i izgled. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 MPO / MTP Products We Manufacture
Skupina 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.
Model
Broj vlakana
sučelje
Tipična uporaba
Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 do 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion
12/24 MPO kazetni modul Core High-Density Solution
12 ili 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base
8/12/24 MPO MTP baza za 24 LC Ultra visoka gustoća 1U modularna
Sve do 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows
Skupina 2 — Rack Patch Panels
Empty or pre-assembled 1U 19-inch chassis to hold cassette modules and to organise trunk cables at the top of the rack.
Model
Rack Size
Loading
Tipična uporaba
Data Center 19-inch Standard Rack MPO Patch Panel
1U
Empty chassis for cassettes
Standard MDA rack, modular build
Pre-assembled 1U 19-inch Rack LC MTP®/MPO Patch Panel
1U
Pre-terminated LC front, MPO back
Plug-and-play rack, no field assembly
Skupina 3 — Patch Cords and Trunk Cables
The physical link between MPO cassettes, patch paneli, transceivers and MPO backbone runs.
Model
Struktura
Fiber Options
Tipična uporaba
Factory Pre-termination MPO-MPO 3.0mm LSZH Patch Cord / Trunk Cable
MPO to MPO
OS2 / OM3 / OM4 / OM5
Backbone trunk, MDA to EDA
Optički MPO MTP konektor patch kabel
MPO to MPO
OS2 / OM3 / OM4 / OM5
Rack-to-rack short jumper
FTTA MPO/MTP Fiber Optic Patch Cord Cable
MPO to MPO, outdoor jacket
OS2 / OM3 / OM4
Base station FTTA and outdoor short link
Skupina 4 — Loopback
Used to test transceiver ports, cassette continuity and rack integrity without pulling a full trunk link.
Model
sučelje
Vlakno
Tipična uporaba
OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
OM3 višemodni
Multimode transceiver and cassette test
Skupina 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.
Model
Odmjeriti
Tipična uporaba
Sve vrste MPO/MTP čistača
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit
What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
MPO (Push On s više vlakana) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Both mate with each other and both follow the same fiber count and polarity rules. Fibconet manufactures to the MPO standard and supplies MTP-compatible builds on request; the underlying optical spec is identical.
Polarity — Type A, Tip B, Vrsta C
Polaritet
Fiber Sequence
Tipična uporaba
Tip A (Ravno)
1↔1, 2↔2 … 12↔12 straight-through
Point-to-point trunks with A-to-B duplex crossover in the patch cord
Tip B (Reverse)
1↔12, 2↔11 … 12↔1 fully reversed
Direct connection to SFP+ / QSFP transceivers; most common for 40G/100G breakout
Vrsta C (Pair-swap)
Adjacent pairs swapped: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling
Polarity errors are the single most common cause of link-up failure on MPO systems. Confirm polarity at RFQ stage; we ship Type A / B / C per your bill of materials.
Gender — Male (with pins) vs Female (no pins)
Male: two guide pins protrude from the end-face. Used at fixed / patch-panel ends.
Female: no pins, two guide-pin holes only. Used at the equipment / movable-jumper end.
Wrong gender at RFQ = the entire batch has to be re-terminated. Always specify Male-Female, Female-Female or Male-Male at the quotation stage.
Fiber Type — Match to Data Rate and Distance
Vlakno
Valna duljina
10G reach
40G / 100G reach
Tipična uporaba
OM3 višemodni
850 nm
550 m
100 m / 100 m (SR4)
Short rack-to-rack, cost-sensitive builds
OM4 multimode
850 nm
550 m
150 m / 150 m (SR4)
Standard data-center backbone
OM5 multimode
850 & 953 nm SWDM
550 m
≥ 150 m; supports 400G SR4.2
AI cluster and next-gen supercompute backbone
OS2 singlemode
1310 / 1550 nm
10 km +
10 km + (LR4 / DR4)
Inter-building, kampus, DCI long-haul
Insertion Loss Grade — Standard vs Low-Loss
Razred
Max IL per mated pair
Povratni gubitak
Tipična uporaba
Standard (SM APC)
≤ 0.70 dB
≥ 55 dB
Enterprise LAN, standard data-center runs
Low-Loss / Elita (SM APC)
≤ 0.35 dB (tipičan 0.25 dB)
≥ 55 dB
Cabinet-to-cabinet 100G high-density backbone
Ultra Low-Loss (Japanese ferrule)
0.15 dB per single fiber
≥ 55 dB
400G / 800G AI backbone; long link budgets
Standard (MM PC)
≤ 0.50 dB
≥ 20 dB
OM3/OM4 short data-center runs
Low-Loss (MM PC)
≤ 0.35 dB (tipičan 0.20 dB)
≥ 20 dB
OM4/OM5 high-density backbone
Tehničke specifikacije
Bilješka: the values below are family-typical across the 10 niz, nije podatkovna tablica za jedan SKU. Ask us for the model-specific test report at RFQ stage; šaljemo pod kataloškim brojem modela.
Parametar
Tipična vrijednost
Komentar
Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone
Vrsta vlakana
OS2 (G.652.D, G.657.A1/A2), OM3, OM4, OM5
G.657.A2 for tight-radius rack routing
Polaritet
Tip A / Tip B / Vrsta C
Type B is default for 40G/100G breakout
Spol
Male (with pins) / Female (no pins)
Both ends selectable per port
End-face polish
APC (jednomodni) / PC (multimod)
APC green, PC beige/aqua
Gubitak umetanja (pojedinačno vlakno)
0.15 – 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules
Povratni gubitak
≥ 55 dB (SM APC), ≥ 45 dB (SM PC), ≥ 20 dB (MM PC)
Trajnost parenja
≥ 500 ciklusi, IL drift ≤ 0.2 dB
Guide-pin positioning with elastic pre-load
Minimalni radijus savijanja
MPO end ≥ 30 mm; LC breakout end ≥ 20 mm
Statički 15 mm, dinamičan 30 mm on G.657.A2 fiber
Radna temperatura
−20°C to +60°C
Optical performance stable across the range
Ingress / vlažnost
IP50; 45°C / 95% RH; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed
Length range
0.2 do 300 m custom; · Lako se montira mehaničkim spojem i bez poliranja
· Minimizirajte stopu kvarova značajkama uklanjanja i ponovne upotrebe 0.5 do 30 m
Per model
Trunk cable OD
3.0 mm tipično (8/12/16/24F); ~5.0 mm (48F)
Higher fiber count = larger OD
Jakna
LSZH standard; OFNR / OFNP on request
Suitable for data hall, riser and plenum
Testna valna duljina
1310 / 1550 nm (SM), 850 / 1300 nm (MM)
Jamstvo
1 godina; design life up to 10 godine
Field replacement covered within warranty period
Mogućnosti proizvodnje i kontrola kvalitete
Production Line and Monthly Capacity
Matična operacija Fibconeta u optičkim pasivnim komponentama datira iz 1994. MPO / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 komada. Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
Upstream Material Control
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. We control the upstream stack rather than only the assembly step:
Berrule: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
Vlakno: YOFC / Fiberhome / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
Aramidna pređa: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.
100% Inspekcija kvalitete
Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
Polaritet i redoslijed vlakana: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.
Certifikati i sukladnost
Fibconet operates under an integrated ISO 9001 / ISO 14001 / ISO 45001 management system covering quality, environment and occupational health & sigurnost. Raw-material RoHS reports ship by default. Product-level compliance — CE, REACH, the, ETL — is issued per model and per target market. Certification applicability varies by product and project requirements. Send us your target market and the model list; we return the applicable certificate set with the quotation.
Ambalaža, OEM and Custom Options
Standardno pakiranje
Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, količina, polarity and gender code.
OEM and Custom Options
Duljina: any length from 0.2 m do 300 m, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 cm) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3×8 / 4×6; 16F to 2×8; 48F to 6×8; do 6 MPO konektori po jednom kraju na MPO-na-MPO spojevima.
Polaritet: Tip A / B / C po portu; unutarnje križanje na tipu B za izravno spajanje SFP-a.
Ferrule grade: domaći Sanhuan ili japanski uvezeni po broju vlakana / Izbor razreda IL.
Boja jakne: aqua (OM3), Erika Violet (OM4), zelena limeta (OM5), žuta boja (OS2), prilagođeni RAL.
Zaštita korijena od izbijanja: nijedan (kratke staze), najlonska čizma (standardni stalak), pleteni rukav (visoke istrošenosti).
OEM naljepnica i tisak: na tijelu konektora, PE vrećica i glavni karton.
Prilagođeno pakiranje: Dizajn PE vrećice i kartona prema vašem umjetničkom djelu, MOQ 30,000 kom za kompletno prilagođeno pakiranje.
Uzorci: besplatni uzorci male količine za provjeru kvalitete; plaća se samo trošak dostave, može se odbiti od prve skupne narudžbe.
Često postavljana pitanja
P1. Koja je razlika između MPO i MTP®?
MPO je generički IEC 61754-7 standard konektora s više vlakana. MTP je implementacija robne marke US Conec istog standarda sa strožim mehaničkim tolerancijama na držaču igle vodilice i unutarnjom zaštitom vrpce. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Q2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100G, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Q3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100G / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / SC / FC on the other?
Da. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
P5. Are both ends symmetric on MPO-to-MPO breakout cables?
Da. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. Sve do 6 MPO connectors per single end are supported.
P6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100G SR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; we ship Type A / B / C per your bill of materials.
P7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 dB. Ultra low-loss builds with Japanese ferrules reach 0.15 dB per single fiber. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
P8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
Da. Every cable and every fiber core is tested for insertion loss, povratni gubitak, end-face geometry, polaritet, slijed vlakana, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
P9. Can I get samples before placing a bulk order?
Da. Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
P10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 komada. Standard orders of several thousand pieces ship in 7–12 days from stock. Skupne narudžbe iznad 20,000 komadi isporučuju se za 15-20 dana. Prilagođeno pakiranje s cjelovitim umjetničkim djelom počinje od MOQ-a od 30,000 kom.
P11. Mogu li se ovi MPO proizvodi koristiti na otvorenom?
Standardna linija MPO optimizirana je za podatkovnu dvoranu, MDA i rack okruženja (IP50, −20°C to +60°C, LSZH). Za vanjsku i FTTA primjenu, koristite FTTA MPO/MTP spojni kabel s optičkim vlaknima s vanjskim omotačem, ili zatražite vanjsku konstrukciju po narudžbi. Ne postavljajte standardnu unutarnju jaknu u nezaštićenim vanjskim uvjetima.
P12. Kolika je garancija?
Standardno jamstvo je 1 godina; vijek trajanja dizajna je do 10 godine. Jer 100% inspekcija se provodi na svakoj jedinici, kvarovi na terenu su rijetki; kada se pojave unutar jamstvenog roka, odmah šaljemo zamjenu.
Odgovorit ćemo unutar 12 sati, obratite pozornost na e-mail sa sufiksom “@fibconet.com”.
Također, možete otići do Kontakt stranica, koji pruža detaljniji oblik.