Uredi prijevod
traži

Patch kabel od optičkih vlakana & Kikice

Patch kabel od optičkih vlakana & Pigtail Manufacturer — SC/LC/FC/MPO, Zatvoreni, Vanjski & Oklopljeni

FIBCONET proizvodi optička vlakna patch kabeli i pigtails across five product families — simplex & duplex indoor, waterproof drop, oklopljeni, MPO high-density, and ODF pigtails — with combined output exceeding 13 million cords per month. Every cord is 100% ispitan na uneseni gubitak, povratni gubitak, tensile strength and end-face quality before packaging.

Our patch cords meet the corresponding test requirements defined in IEC 61300 (Klasa U) i Telcordia GR-326-CORE (Klasa R). Optical fiber comes from China’s four leading brands — YOFC, ZTT, Hengtong i Fiberhome. Ceramic ferrules use the CCTC series (Sumitomo ferrules available on request), and connector grades run from network-level to telecom-level to match your project’s cost and performance profile.

Beyond standard telecom cords, naše MPO / MTP high-density line supports 40G, 100G, 400G and 800G parallel optical transmission — the current mainstream for AI-driven data-centre buildouts and hyperscale MDA cabling. See the MPO section below.

raw material of patch cord

5 Patch kabel & Pigtail Series We Manufacture

Niz Tipična uporaba Ključne specifikacije Priključci
Indoor Simplex & Duplex Patch Cord Data-centre patching, telecom room, cross-connect, in-cabinet routing Insertion loss avg ≤ 0.3 dB; rastezljivo 45 N; 2.0 / 3.0 mm jakna; LSZH available SC, LC, FC, SV, MU, MTRJ, E2000 — PC / UPC / APC
Vanjski & Waterproof Drop Patch Cord FTTH pad, outdoor terminal box, CPRI fronthaul, base-station link IP-rated seal; UV-resistant jacket; pre-connectorized options for 1–4 core drop Mini SC, SC/APC, LC/APC waterproof
Oklopljeni & Anti-Rat Patch Cord Data-centre under-floor, in-conduit runs, underground burial, oštra okruženja 201 stainless-steel spiral armor; rastezljivo 140 N (2× standard); slani sprej 24 h; operating −40 to +85 °C SC, LC, FC — UPC / APC
MPO / MTP High-Density Cord Data-centre MDA, AI compute cluster fabric, 40G/100G/400G/800G parallel optics, high-density cabinet Sve do 72 fibers per MPO; single-mode IL down to 0.15 dB; multimode low-loss ≤ 0.35 dB; ≥ 500 ciklusi parenja MPO / MTP male & female; hybrid MPO–LC / MPO–SC / MPO–FC breakout
Indoor Pigtail ODF splicing, distribution box terminals, fusion-splice on-site 0.9 mm buffered pigtail; · Lako se montira mehaničkim spojem i bez poliranja · Minimizirajte stopu kvarova značajkama uklanjanja i ponovne upotrebe 1.5 m length; custom lengths supported SC, LC, FC — UPC / APC

Every series above is 100% factory-tested (end-face, insercijski gubitak, povratni gubitak, rastezljivo). Electronic test reports in FLUKE or EXFO format are available with each order.

konektor

Patch Cord vs Pigtail — What’s the Difference?

Patch kabel Kikice
Connectorization Connectors on both ends Connector on one end only; other end bare fiber for fusion splicing
Primary use Equipment-to-equipment or equipment-to-panel ODF / distribution-box termination, fusion-spliced to the incoming cable
Duljina Tipično 0.5 – 30 m; običaj do 300 m Tipično 1.0 – 1.5 m; custom on request
Montaža Plug-and-play Requires fusion splicer on-site
Najbolje za Data centre patching, MDA, cross-connect, PON drop Central office, ODF panel splicing, distribution frames

How to Choose the Right Connector, Jacket and Fiber

Vrste konektora & End-Face Contact

We manufacture patch cords with all mainstream connectors: FC, SV, SC, LC, MU, MPO / MTP, E2000, MTRJ, SMA. End-face contact is available in three types:

  • PC (Fizički kontakt) — return loss around 40 dB, legacy applications
  • UPC (Ultra fizički kontakt) — povratni gubitak ≥ 50 dB, mainstream data-centre and enterprise
  • APC (Fizički kontakt pod kutom, 8°) — povratni gubitak ≥ 55 dB, PON / FTTH / CATV where high RL is critical

For module ports, LC, SC and MPO / MTP dominate. LC is the default for high-density optical modules; SC is standard for FTTH; MPO handles high-count parallel links.

Jacket Material Selection

Jacket type Najbolje za Bilješke
Standard PVC General indoor use Lowest cost
Flame-Retardant PVC Podatkovni centri, plenums with local fire code Meets basic flame ratings
LSZH (Low Smoke Zero Halogen) Podatkovni centri, telecom rooms, tuneli, podzemne željeznice No halogens, low smoke, no corrosive gas — European & DC standard
LSZH Flame-Retardant Strict fire-code data centres and public buildings Combines LSZH with elevated flame retardance
201 Stainless-Steel Armored Vanjski, pokopan, rodent-prone, harsh environment 140 N vlačna; 24 h salt-spray

Vrsta vlakana & Standard Selection

  • Jednostruki način rada (9 µm core): long-distance, low dispersion — G.652.D backbone; G.657.A1/A2 bend-insensitive for tight cabling
  • Multimode: 50 µm (OM3 / OM4 / OM5) for modern data centres; 62.5 µm (OM1) for legacy systems only
  • ITU-T single-mode grades supported: G.652.D, G.654.E, G.657.A1, G.657.A2, G.657.B3
  • Multimode grades: OM1, om2, OM3, OM4, OM5 — OM3/OM4/OM5 all support 10G at 550 m

Broj jezgri & Custom Length

Jednojezgreni (jednostavan), dvostruki (dupleks), and multi-core cables in 4, 6, 8, 12, 24, 48 i 72 jezgre konfiguracije. Custom core counts and lengths supported on request. Standard patch cord lengths run 0.5–30 m; custom lengths up to 300 m for special projects. Standard pigtail length is 1.0 – 1.5 m.

MPO / MTP High-Density Cable — Our Future-Focused Line ⭐

MPO / MTP is the connector platform driving the next decade of data-centre and AI cabling. A single MPO connector carries 8, 12, 16, 24, do 72 vlakna, replacing dozens of individual patch cords with one plug. Our dedicated MPO production runs 150,000 cords per month s 100% ferrule interferometer inspection and per-core polarity verification.

Ubrzati & Link Support

Link Speed Fiber Count Required Vrsta vlakana Doseg
40G SR4 8 vlakna (4Tx + 4Rx) OM3 / OM4 Sve do 550 m (OM4)
100G SR4 / SR10 8 ili 20 vlakna OM3 / OM4 / OM5 Sve do 550 m
400G SR8 / DR4 16 vlakna / 8 vlakna OM4 / OM5 / jednonačin Sve do 100 m (SR8) / 500 m (DR4)
800G SR8 16 vlakna OM4 / OM5 Sve do 100 m — today’s AI cluster mainstream

MPO Configurations We Manufacture

  • Straight MPO–MPO trunk — direct panel-to-panel or module-to-module link
  • MPO breakout (MPO to LC/SC/FC) — splits a single high-count MPO into 4, 6, 8, 12, 24 duplex breakouts. Default configurations: 24-core → 12 duplex LC; 12-core → 6 duplex LC. Custom splits welcome.
  • MPO–MPO breakout — single-ended maximum 6 MPO konektori. Both ends must be symmetric (npr. 2×12 to 2×12). Common splits for 24-core: 2×12, 3×8, 4×6.
  • Hybrid combinations — one end MPO + one end LC / SC / FC

Polaritet & Spol

  • Tip A (ravno-prolazni) — key-up to key-down; standard for parallel optics
  • Tip B (reversed) — key-up to key-up; used with fanout modules
  • Vrsta C (pairs-crossed) — each fiber pair swapped; legacy duplex applications
  • Spol: Male (with alignment pins, fixed / panel side) or Female (no pins, oprema / patch side)

When you place an order, please confirm polarity type, gender configuration, connector-color scheme, and core-count breakout — our sales team will validate against your target optical modules before production begins.

MPO Quality Control

  • 100% 3D interferometer end-face inspection on every ferrule
  • Per-core insertion loss, povratni gubitak, polaritet, slijed vlakana, duljina, and appearance verification
  • Batch-to-batch insertion-loss variation controlled within ±0,08 dB
  • Ferrules sourced from qualified suppliers — imported (Japanese) and domestic options; domestic precision now matches import quality at a better cost point

Technical Specifications Across All Series

Parametar Vrijednost
Testni standard IEC 61300 (Klasa U); Telcordia GR-326-CORE (Klasa R)
Gubitak umetanja (tipičan) Standard ≤ 0.3 dB; low-loss grade ≤ 0.15 dB (MPO single-mode)
Povratni gubitak UPC ≥ 50 dB; APC ≥ 55 dB
Radna temperatura −20 do +60 °C (· Lako se montira mehaničkim spojem i bez poliranja · Minimizirajte stopu kvarova značajkama uklanjanja i ponovne upotrebe); −40 do +85 °C (oklopljeni & branch series)
Temperatura skladištenja −40 do +85 °C
Trajnost parenja SC / LC / FC ≥ 1,000 ciklusi; MPO ≥ 500 ciklusi
Vlačna čvrstoća Standard 45 N; podružnica 40 N (dugoročno); oklopljeni 140 N
Minimalni radijus savijanja Standard cord 10 mm; MPO branch 15 mm static / 30 mm dynamic; armored 35–40 mm
Jamstvo 1-year factory warranty; design service life 10 godine

test report

Mogućnosti proizvodnje i kontrola kvalitete

Combined Monthly Output: 13,000,000+ Cords

Niz Mjesečni učinak
Simplex patch cord 10,000,000 cords
Duplex patch cord (top-3 producer nationally) 3,000,000 cords
MPO / MTP series 150,000 cords
Breakout patch cord 90,000 cords

Raw Material Sourcing

Optical fiber sourced from China’s four leading brands — YOFC, ZTT, Hengtong i Fiberhome — the same feedstock trusted by tier-1 operators worldwide. Ceramic ferrules are Sanhuan series by default, s Sumitomo ferrules available on request for the tightest concentricity requirements. Jacket compounds come from Shanghai Kaibo, a stable supplier to the same four fiber manufacturers.

100% Inspection Before Shipment

  • End-face inspection na svakom konektoru — interferometar za MPO, standard microscope for SC/LC/FC
  • Gubitak umetanja & povratni gubitak test on every core, using dedicated IL/RL test equipment
  • Vlačna čvrstoća test on every batch
  • Electronic test reports (FLUKE / EXFO format) dostupno uz svaku narudžbu
  • 3D end-face inspection available on request — standard on all MPO production

Batch Consistency

Insertion-loss variation between production batches is held within ±0,08 dB. Colour consistency for OEM orders is managed by keeping a first-piece reference sample from every batch for direct comparison on subsequent orders.

Certifikati i sukladnost

  • IEC 61300 (Klasa U) — passive fibre optic component test methods
  • Telcordia GR-326-CORE (Klasa R) — single-mode connector reliability
  • ISO 9001 Sustav upravljanja kvalitetom
  • RoHS raw material compliance reports available
  • the / ETL / TUV testing available on request for North American and European market entry — our products meet the required test standards; third-party certification arranged per project.

Primjenjivost certifikacije ovisi o liniji proizvoda i odredišnom tržištu. Please confirm target market and required standards when requesting a quotation.

OEM, Ambalaža & Prilagođene opcije

  • Duljina: fully custom from 0.2 m do 300 m; standard stock in 1 m, 2 m, 3 m, 5 m, 10 m
  • Colour: connector boots and jackets in gray, plava, zelena, bijelim, Crvena, crno, aqua — used for port identification
  • OEM markiranje: custom logo printing, PE vrećice privatne robne marke, branded colour boxes, logotip vanjske kutije, spec-sheet inserts — MOQ from 5,000 pieces for printed packaging
  • Neutral packaging: available without minimum quantity
  • Individual packing: every cord in a single PE bag; carton counts confirmed by cord length and jacket type

Frequently Asked Questions About Patch Cord & Pigtail Sourcing

P1. What is your minimum order quantity for standard patch cords?

Standard simplex and duplex patch cords have no MOQ — sample and trial orders are welcome. MPO cords typically start at 100 jedinice. Armored cords have a 1,000-piece MOQ due to armor tooling setup; delivery within 10 dana. OEM-printed packaging requires 5,000 pieces minimum.

Q2. What is the lead time?

Regular configurations of simplex, duplex and standard MPO ship from stock within days — we keep 2,000–3,000 pieces of common SKUs like SC/UPC duplex 2.0 mm LSZH in-stock. MPO custom orders: 7–12 days for a few thousand pieces; 15–20 days for orders above 20,000 komada. Branch patch cords: samples ready in 3 dana.

Q3. Can you provide test reports and 3D end-face inspection?

Da. Every cord ships with 100% factory testing (THE, RL, end-face, rastezljivo). Elektronička izvješća o ispitivanju u FLUKE ili EXFO format are available after order placement. 3D end-face inspection is standard on all MPO production and available on request for other cord types.

Q4. What insertion-loss levels can you achieve on MPO?

Standard-grade MPO: insertion loss ≤ 0.7 dB (multimod 850 / 1310 nm). Low-loss grade: ≤ 0.35 dB prosjek. Single-mode MPO with high-precision imported ferrules can reach IL as low as 0.15 dB for testing and telecom-grade applications. Standard grade covers enterprise networks and office cabling; low-loss grade is designed for high-density cabinet cabling and 100G+ mainstream links.

P5. Can you customize MPO breakout ratios and lengths?

Da. Standard MPO breakout defaults: 12-core → 6 duplex LC; 24-core → 12 duplex LC. Custom splits including 2×12, 3×8, 4×6 and other ratios are fully supported. MPO–MPO breakout allows up to 6 MPO connectors on a single end, with both ends symmetric. Trunk length range: 0.2 m do 300 m; branch length differences within a single cable should stay within 30 cm to avoid fiber-stress attenuation drift.

P6. What speeds do your MPO cords support?

Our MPO cords stably support 40G, 100G, 400G and 800G parallel optical transmission. This makes them suitable for current AI data-centre cluster fabric, hyperscale MDA cabling, and next-generation coherent transport buildouts. OM4 / OM5 multimode is the current mainstream for 400G / 800G SR8 links; single-mode covers longer reach and DR4 architectures.

P7. Do you offer UL / ETL / TUV certifications for North American and European markets?

Da. Our patch cords meet the applicable UL, ETL and TUV test standards. Formal third-party certification can be arranged per project on request — test cost is quoted separately depending on the scope required.

P8. Which fiber and ferrule brands do you use?

Optical fiber from YOFC, ZTT, Hengtong i Fiberhome. Ceramic ferrules are Sanhuan by default; Sumitomo ferrules available on request. Connector grades range from network-level (mainstream cost-performance) to telecom-level (highest concentricity, lowest IL) — specify per project.

P9. What about armored patch cords — how strong are they and where can I use them?

Our armored patch cords use a 201 stainless-steel spiral armor layer. Vlačna čvrstoća doseže 140 N (versus 70 N for standard cords) and the armor passes a 24-hour salt-spray test, making them suitable for marine shipping and coastal deployments. Best for static routing with occasional bending — not recommended for high-frequency repeated flexing. For buried installations, an additional protective conduit is recommended to prevent long-term corrosion.

P10. Do you provide OEM and private-label service?

Da. Izrađujemo prema vašim umjetničkim djelima — kutije u boji po narudžbi, logotip vanjske kutije, PE vrećice privatne robne marke, umeci sa specifikacijama i markirani priručnici. Neutral packaging is available with no minimum quantity. Printed packaging with custom logo requires 5,000 pieces minimum to justify plate setup.

Dobijte brzu ponudu

Odgovorit ćemo unutar 12 sati, obratite pozornost na e-mail sa sufiksom “@fibconet.com”.

Također, možete otići do Kontakt stranica, koji pruža detaljniji oblik.