MPO / MTP Data Center Cabling Manufacturer — Cassettes, Patch Panels, Trunk Cables and Patch Cords
Fibconet उत्पादन गर्दछ 10 series of MPO / MTP fiber optic products for 40G, 100G, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.
Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 टुक्राहरू across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 dB on assemblies built with Japanese-imported ferrules, and to typical 0.20–0.35 dB on standard builds with domestic Sanhuan ferrules.
Every finished cable is 100% inspected for insertion loss, फिर्ता घाटा, end-face geometry, ध्रुवता, फाइबर अनुक्रम, लम्बाइ र उपस्थिति. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 MPO / MTP Products We Manufacture
समूह 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.
मोडेल
फाइबर गणना
इन्टरफेस
सामान्य प्रयोग
Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 को 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion
12/24 कोर उच्च घनत्व समाधान MPO क्यासेट मोड्युल
12 वा 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base
8/12/24 MPO MTP को आधार 24 LC अल्ट्रा उच्च घनत्व 1U मोड्युलर
सम्म 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows
समूह 2 — Rack Patch Panels
Empty or pre-assembled 1U 19-inch chassis to hold cassette modules and to organise trunk cables at the top of the rack.
मोडेल
Rack Size
Loading
सामान्य प्रयोग
Data Center 19-inch Standard Rack MPO Patch Panel
1U
Empty chassis for cassettes
Standard MDA rack, modular build
Pre-assembled 1U 19-inch Rack LC MTP®/MPO Patch Panel
1U
Pre-terminated LC front, MPO back
Plug-and-play rack, no field assembly
समूह 3 — Patch Cords and Trunk Cables
The physical link between MPO cassettes, प्याच प्यानलहरू, transceivers and MPO backbone runs.
मोडेल
संरचना
Fiber Options
सामान्य प्रयोग
Factory Pre-termination MPO-MPO 3.0mm LSZH Patch Cord / Trunk Cable
MPO to MPO
OS2 / OM3 / OM4 / OM5
Backbone trunk, MDA to EDA
फाइबर अप्टिक MPO MTP कनेक्टर प्याच कर्ड
MPO to MPO
OS2 / OM3 / OM4 / OM5
Rack-to-rack short jumper
FTTA MPO/MTP Fiber Optic Patch Cord Cable
MPO to MPO, outdoor jacket
OS2 / OM3 / OM4
Base station FTTA and outdoor short link
समूह 4 — Loopback
Used to test transceiver ports, cassette continuity and rack integrity without pulling a full trunk link.
मोडेल
इन्टरफेस
फाइबर
सामान्य प्रयोग
OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
OM3 मल्टिमोड
Multimode transceiver and cassette test
समूह 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.
मोडेल
मिल्छ
सामान्य प्रयोग
सबै प्रकार फिटिंग MPO / MTP क्लीनर
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit
What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
MPO (बहु-फाइबर पुश अन) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Both mate with each other and both follow the same fiber count and polarity rules. Fibconet manufactures to the MPO standard and supplies MTP-compatible builds on request; the underlying optical spec is identical.
Polarity — Type A, B टाइप गर्नुहोस्, C टाइप गर्नुहोस्
ध्रुवता
Fiber Sequence
सामान्य प्रयोग
A टाइप गर्नुहोस् (Straight)
1↔1, 2↔2 … 12↔12 straight-through
Point-to-point trunks with A-to-B duplex crossover in the patch cord
B टाइप गर्नुहोस् (Reverse)
1↔12, 2↔11 … 12↔1 fully reversed
Direct connection to SFP+ / QSFP transceivers; most common for 40G/100G breakout
C टाइप गर्नुहोस् (Pair-swap)
Adjacent pairs swapped: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling
Polarity errors are the single most common cause of link-up failure on MPO systems. Confirm polarity at RFQ stage; we ship Type A / बि / C per your bill of materials.
Gender — Male (with pins) vs Female (no pins)
Male: two guide pins protrude from the end-face. Used at fixed / patch-panel ends.
Female: no pins, two guide-pin holes only. Used at the equipment / movable-jumper end.
Wrong gender at RFQ = the entire batch has to be re-terminated. Always specify Male-Female, Female-Female or Male-Male at the quotation stage.
Fiber Type — Match to Data Rate and Distance
फाइबर
तरंगदैर्ध्य
10G reach
40G / 100G reach
सामान्य प्रयोग
OM3 मल्टिमोड
850 nm
550 m
100 m / 100 m (SR4)
Short rack-to-rack, cost-sensitive builds
OM4 मल्टिमोड
850 nm
550 m
150 m / 150 m (SR4)
Standard data-center backbone
OM5 multimode
850 & 953 nm SWDM
550 m
≥ 150 m; supports 400G SR4.2
AI cluster and next-gen supercompute backbone
OS2 singlemode
1310 / 1550 nm
10 km +
10 km + (LR4 / DR4)
Inter-building, क्याम्पस, DCI long-haul
Insertion Loss Grade — Standard vs Low-Loss
ग्रेड
Max IL per mated pair
फिर्ता घाटा
सामान्य प्रयोग
मानक (SM APC)
≤ 0.70 dB
≥ 55 dB
Enterprise LAN, standard data-center runs
Low-Loss / कुलीन (SM APC)
≤ 0.35 dB (विशिष्ट 0.25 dB)
≥ 55 dB
Cabinet-to-cabinet 100G high-density backbone
Ultra Low-Loss (Japanese ferrule)
0.15 dB per single fiber
≥ 55 dB
400G / 800G AI backbone; long link budgets
मानक (MM PC)
≤ 0.50 dB
≥ 20 dB
OM3/OM4 short data-center runs
Low-Loss (MM PC)
≤ 0.35 dB (विशिष्ट 0.20 dB)
≥ 20 dB
OM4/OM5 high-density backbone
प्राविधिक विनिर्देशहरू
नोट: the values below are family-typical across the 10 series, एकल-SKU डाटाशीट होइन. Ask us for the model-specific test report at RFQ stage; हामी यसलाई मोडेल भाग नम्बर अन्तर्गत पठाउँछौं.
प्यारामिटर
सामान्य मान
टिप्पणी गर्नुहोस्
Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone
फाइबर प्रकार
OS2 (G.652.D, G.657.A1/A2), OM3, OM4, OM5
G.657.A2 for tight-radius rack routing
ध्रुवता
A टाइप गर्नुहोस् / B टाइप गर्नुहोस् / C टाइप गर्नुहोस्
Type B is default for 40G/100G breakout
लिङ्ग
Male (with pins) / Female (no pins)
Both ends selectable per port
End-face polish
APC (सिंगलमोड) / पीसी (मल्टिमोड)
APC green, PC beige/aqua
प्रविष्टि हानि (एकल फाइबर)
0.15 – 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules
फिर्ता घाटा
≥ 55 dB (SM APC), ≥ 45 dB (SM PC), ≥ 20 dB (MM PC)
मिलन स्थायित्व
≥ 500 चक्रहरू, IL drift ≤ 0.2 dB
Guide-pin positioning with elastic pre-load
न्यूनतम मोड त्रिज्या
MPO end ≥ 30 mm; LC breakout end ≥ 20 mm
स्थिर 15 mm, गतिशील 30 mm on G.657.A2 fiber
सञ्चालन तापमान
−20°C to +60°C
Optical performance stable across the range
Ingress / आद्र्रता
IP50; 45°C / 95% आरएच; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed
Length range
0.2 को 300 m custom; · 3mm ड्रप केबल र 3x2mm फ्ल्याट केबल दुवै संग उपयुक्त
· छिटो र सजिलो स्थापना 0.5 को 30 m
Per model
Trunk cable OD
3.0 मिमी सामान्य (8/12/16/24एफ); ~5.0 mm (48एफ)
Higher fiber count = larger OD
ज्याकेट
LSZH standard; OFNR / OFNP on request
Suitable for data hall, riser and plenum
परीक्षण तरंगदैर्ध्य
1310 / 1550 nm (SM), 850 / 1300 nm (MM)
वारेन्टी
1 वर्ष; design life up to 10 वर्ष
Field replacement covered within warranty period
उत्पादन क्षमता र गुणस्तर नियन्त्रण
Production Line and Monthly Capacity
अप्टिकल निष्क्रिय कम्पोनेन्टहरूमा फिबकोनेटको अभिभावक सञ्चालनको मिति फिर्ता हुन्छ 1994. MPO / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 टुक्राहरू. Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
Upstream Material Control
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. We control the upstream stack rather than only the assembly step:
फेरुल्स: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
फाइबर: YOFC / फाइबरहोम / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
अरामिड धागो: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.
100% गुणस्तर निरीक्षण
Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
ध्रुवता र फाइबर अनुक्रम: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.
प्रमाणीकरण र अनुपालन
Fibconet operates under an integrated ISO 9001 / ISO 14001 / ISO 45001 management system covering quality, environment and occupational health & सुरक्षा. Raw-material RoHS reports ship by default. Product-level compliance — CE, पुग्नुहोस्, द, ETL — is issued per model and per target market. Certification applicability varies by product and project requirements. हामीलाई तपाईंको लक्षित बजार र मोडेल सूची पठाउनुहोस्; हामी उद्धरणको साथ सेट लागू प्रमाणपत्र फिर्ता गर्छौं.
प्याकेजिङ, OEM and Custom Options
Standard Packaging
Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, मात्रा, polarity and gender code.
OEM and Custom Options
लम्बाइ: any length from 0.2 m देखि 300 m, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 सेमी) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3×८ / 4×6; 16F to 2×8; 48F to 6×8; सम्म 6 MPO connectors per single end on MPO-to-MPO breakouts.
ध्रुवता: A टाइप गर्नुहोस् / बि / C per port; internal crossover on Type B for direct SFP mating.
Ferrule grade: domestic Sanhuan or Japanese-imported per fiber-count / IL grade selection.
Jacket color: एक्वा (OM3), erika violet (OM4), कागत हरियो (OM5), पहेंलो (OS2), custom RAL.
Breakout root protection: कुनै पनि (short runs), nylon boot (standard rack), braided sleeve (high-wear).
OEM label and printing: on connector body, PE bag and master carton.
Custom packaging: PE bag and carton design per your artwork, MOQ 30,000 pcs for full custom packaging run.
Samples: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.
बारम्बार सोधिने प्रश्नहरू
Q1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Q2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100G, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Q3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100G / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / SC / FC on the other?
हो. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
Q5. Are both ends symmetric on MPO-to-MPO breakout cables?
हो. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. सम्म 6 MPO connectors per single end are supported.
Q6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100G SR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; we ship Type A / बि / C per your bill of materials.
Q7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 dB. Ultra low-loss builds with Japanese ferrules reach 0.15 dB per single fiber. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
Q8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
हो. Every cable and every fiber core is tested for insertion loss, फिर्ता घाटा, end-face geometry, ध्रुवता, फाइबर अनुक्रम, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
Q9. Can I get samples before placing a bulk order?
हो. Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
Q10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 टुक्राहरू. Standard orders of several thousand pieces ship in 7–12 days from stock. Bulk orders above 20,000 pieces ship in 15–20 days. Custom packaging with full artwork runs from an MOQ of 30,000 pcs.
Q11. Can these MPO products be used outdoors?
The standard MPO line is optimised for data hall, MDA and rack environments (IP50, −20°C to +60°C, LSZH). For outdoor and FTTA applications, use the FTTA MPO/MTP Fiber Optic Patch Cord with an outdoor jacket, or ask for a custom outdoor build. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. What is the warranty?
Standard warranty is 1 वर्ष; design service life is up to 10 वर्ष. Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.
हामी भित्र जवाफ दिनेछौं 12 घण्टा, कृपया प्रत्यय सहितको इमेलमा ध्यान दिनुहोस् "@fibconet.com".
साथै, मा जान सक्नुहुन्छ सम्पर्क पृष्ठ, जसले थप विस्तृत फारम प्रदान गर्दछ.