









MPO / MTP Data Center Cabling Manufacturer — Cassettes, Patch Panels, Trunk Cables and Patch Cords
Fibconet inogadzira 10 series of MPO / MTP fiber optic products for 40G, 100G, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.
Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 zvimedu across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 dB on assemblies built with Japanese-imported ferrules, uye kune yakajairika 0.20–0.35 dB pane akajairwa anovaka ane epamba Sanhuan ferrules.
Yese yapera tambo ndeye 100% yakaongororwa kurasikirwa kwekuisa, kudzokera kurasikirwa, kuguma-chiso geometry, polarity, fiber sequence, kureba nechitarisiko. FLUKE / EXFO yemagetsi bvunzo mishumo inowanikwa mushure mekuodha kusimbiswa. Zvigadzirwa parizvino zvinotumirwa mu hyperscale, telecom uye bhizinesi data-center mapurojekiti muUS, Kanadha, Jerimani, UK neNetherlands.
10 MPO / MTP Zvigadzirwa Isu Tinogadzira
Group 1 — Cassette Modules
Pre-yakagumiswa MPO-kune-LC kana MPO-kune-MPO makaseti ekushandura e1U rack mapaneru.. Iyo yekuvaka yechero yakakwirira-density data-center row.
Model
Fiber Count
Interface
Kushandiswa kwakajairika
Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 ku 144
MPO trunk in / LC duplex kunze
Kushandurwa kweMDA kuenda kuEDA
12/24 Core High-Density Solution MPO Cassette Module
12 kana 24
MPO in / LC kunze
Compact rack inovaka ine 12F kana 24F MPO base
8/12/24 MPP MTP Base 24 LC Ultra High density 1u modular
Kusvika pa 24 LC pa1U
MPO/MTP mukati / 24 LC kunze
Yakanyanya 1U density; AI cluster uye hyperscale rows
Group 2 - Rack Patch Panels
Isina kana pre-yakaungana 1U 19-inch chassis kubata makaseti modules uye kuronga trunk tambo kumusoro kwereki..
Model
Rack Size
Loading
Kushandiswa kwakajairika
Data Center 19-inch Standard Rack MPO Patch Panel
1U
Chassis isina chinhu yemakaseti
Standard MDA rack, modular kuvaka
Pre-yakasanganiswa 1U 19-inch Rack LC MTP®/MPO Patch Panel
1U
Pre-yakamiswa LC kumberi, MPO back
Plug-and-play rack, hapana musangano wemumunda
Group 3 - Patch Cords uye Trunk Cables
Kubatana kwemuviri pakati peMPO makaseti, Patch Panels, transceivers uye MPO musana unomhanya.
Model
Chimiro
Fiber Options
Kushandiswa kwakajairika
Factory Pre-kugumisa MPO-MPO 3.0mm LSZH Patch Cord / Hunde Cable
MPO kuenda kuMPO
OS2 / OM3 / OM4 / OM5
Backbone hunde, MDA kuenda kuEDA
Fiber Optic MPO MTP Connector Patch Cord
MPO kuenda kuMPO
OS2 / OM3 / OM4 / OM5
Rack-to-rack short jumper
FTTA MPO/MTP Fiber Optic Patch Cord Cable
MPO kuenda kuMPO, bhachi rekunze
OS2 / OM3 / OM4
Base chiteshi FTTA uye yekunze ipfupi link
Group 4 — Loopback
Inoshandiswa kuyedza transceiver ports, cassette continuity and rack integrity without pulling a full trunk link.
Model
Interface
Fiber
Kushandiswa kwakajairika
OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
OM3 multimode
Multimode transceiver and cassette test
Group 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.
Model
Inokodzera
Kushandiswa kwakajairika
Ese Mhando Kukodzera MPO/MTP Kuchenesa
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit
What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
MPO (Multi-fiber Push On) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Vese vanobatana uye vese vanoteera yakafanana fiber count uye polarity mitemo. Fibconet inogadzira kune MPO chiyero uye inopa MTP-inoenderana inovaka pakukumbira; iyo yepasi ye optical spec yakafanana.
Polarity - Type A, Type B, Type C
Polarity
Fiber Sequence
Kushandiswa kwakajairika
Type A (Straight)
1↔1, 2↔2 … 12↔12 yakatwasuka
Point-to-point hunde neA-to-B duplex crossover mutambo yechigamba
Type B (Reverse)
1↔12, 2↔11 … 12↔1 yakadzoserwa kumashure zvizere
Yakananga kubatana kuSFP+ / QSFP transceivers; yakajairika ye40G/100G breakout
Type C (Pair-swap)
Peya dziri pedyo dzakachinjaniswa: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling
Polarity kukanganisa ndiyo imwe chete inonyanya kukonzera kukanganisa-up kukundikana pane MPO masisitimu. Simbisa polarity paRFQ nhanho; isu tinotumira Type A / B / C maererano nemari yako yezvinhu.
Gender - Murume (nemapini) vs Mukadzi (hapana mapini)
Murume: two guide pins protrude from the end-face. Used at fixed / patch-panel ends.
Female: hapana mapini, two guide-pin holes only. Used at the equipment / movable-jumper end.
Wrong gender at RFQ = the entire batch has to be re-terminated. Always specify Male-Female, Female-Female or Male-Male at the quotation stage.
Fiber Type — Match to Data Rate and Distance
Fiber
Wavelength
10G reach
40G / 100G reach
Kushandiswa kwakajairika
OM3 multimode
850 nm
550 m
100 m / 100 m (SR4)
Short rack-to-rack, cost-sensitive builds
OM4 multimode
850 nm
550 m
150 m / 150 m (SR4)
Standard data-center backbone
OM5 multimode
850 & 953 nm SWDM
550 m
≥ 150 m; supports 400G SR4.2
AI cluster and next-gen supercompute backbone
OS2 singlemode
1310 / 1550 nm
10 km +
10 km + (LR4 / DR4)
Inter-building, kambasi, DCI long-haul
Insertion Loss Grade — Standard vs Low-Loss
Giredhi
Max IL per mated pair
Dzorera Kurasika
Kushandiswa kwakajairika
Standard (SM APC)
≤ 0.70 dB
≥ 55 dB
Enterprise LAN, standard data-center runs
Low-Loss / Elite (SM APC)
≤ 0.35 dB (normal 0.25 dB)
≥ 55 dB
Cabinet-to-cabinet 100G high-density backbone
Ultra Low-Loss (Japanese ferrule)
0.15 dB per single fiber
≥ 55 dB
400G / 800G AI backbone; long link budgets
Standard (MM PC)
≤ 0.50 dB
≥ 20 dB
OM3/OM4 short data-center runs
Low-Loss (MM PC)
≤ 0.35 dB (normal 0.20 dB)
≥ 20 dB
OM4/OM5 high-density backbone
Tekinoroji Rondedzero
Cherechedza: the values below are family-typical across the 10 series, kwete imwe-SKU dhatabheti. Tibvunze isu yemuenzaniso-chaiwo bvunzo repoti paRFQ nhanho; tinoitumira pasi pemuenzaniso chikamu nhamba.
Parameter
Typical Value
Comment
Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone
Fiber type
OS2 (G.652.D, G.657.A1/A2), OM3, OM4, OM5
G.657.A2 for tight-radius rack routing
Polarity
Type A / Type B / Type C
Type B is default for 40G/100G breakout
Gender
Murume (nemapini) / Female (hapana mapini)
Both ends selectable per port
End-face polish
APC (singlemode) / PC (multimode)
APC green, PC beige/aqua
Kuisa kurasikirwa (imwe fiber)
0.15 - 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules
Dzorera kurasikirwa
≥ 55 dB (SM APC), ≥ 45 dB (SM PC), ≥ 20 dB (MM PC)
Mating durability
≥ 500 cycles, IL drift ≤ 0.2 dB
Guide-pin positioning with elastic pre-load
Minimum bend radius
MPO end ≥ 30 mm; LC breakout end ≥ 20 mm
Static 15 mm, dynamic 30 mm on G.657.A2 fiber
Kushanda tembiricha
−20°C to +60°C
Optical performance stable across the range
Ingress / mwando
IP50; 45°C / 95% RH; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed
Length range
0.2 ku 300 m custom; Yese optical uye mechanical index inosangana nechigamba tambo 0.5 ku 30 m
Per modhi
Trunk cable OD
3.0 mm zvakajairwa (8/12/16/24F); ~5.0 mm (48F)
Higher fiber count = larger OD
Jacket
LSZH standard; OFNR / OFNP on request
Suitable for data hall, riser and plenum
Test wavelength
1310 / 1550 nm (SM), 850 / 1300 nm (MM)
Warranty
1 gore; design life up to 10 makore
Field replacement covered within warranty period
Kugadzira Kugona uye Kudzora Kwemhando
Production Line and Monthly Capacity
Kushanda kwevabereki veFibconet mune zvemeso passive zvikamu zvakadzokera kumashure 1994. The MPO / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 zvimedu. Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
Upstream Material Control
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. Isu tinodzora stack yekumusoro kwete danho regungano chete:
Ferrules: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
Fiber: YOFC / Fiberhome / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
Aramid yarn: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.
100% Quality Inspection
Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
Polarity uye fiber sequence: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.
Certification uye Kutevedzera
Fibconet inoshanda pasi peyakasanganiswa ISO 9001 / ISO 14001 / ISO 45001 manejimendi system inovhara kunaka, nharaunda uye hutano hwebasa & kuchengetedzwa. Raw-material RoHS reports ship by default. Product-level compliance — CE, REACH, the, ETL — is issued per model and per target market. Certification kushanda kunosiyana nechigadzirwa uye zvinodiwa zveprojekiti. Titumire musika wako waunotarirwa uye rondedzero yemhando; tinodzorera chitupa chinoshanda chakaiswa pamwe nekotesheni.
Packaging, OEM uye Tsika Sarudzo
Standard Packaging
Each patch cord / trunk tambo yakavharwa mune yega PE bag.
Makaseti uye zvigamba mapaneru foam-yakasungirirwa mubhokisi remukati.
Master export carton yakanyorwa nemodhi, quantity, polarity uye gender code.
OEM uye Tsika Sarudzo
Urefu: chero hurefu kubva 0.2 m kuti 300 m, cheka kune yako bhiri yezvinhu.
Kuputika kwegumbo kureba: makumbo ega ega anoputika akachekwa kusvika pakureba kwakasiyana (kureba musiyano ≤ 30 cm) yezvikepe zvakadzika.
Breakout configuration: 24F kusvika 2 × 12 / 3×8 / 4×6; 16F kusvika 2×8; 48F kusvika 6 × 8; kusvika pa 6 MPO zvibatanidza pamagumo ega paMPO-kune-MPO kubuda.
Polarity: Type A / B / C pachiteshi; yemukati crossover paRudzi B yeyakananga SFP mating.
Ferrule giredhi: mudzimba Sanhuan kana Japanese-imported per faibha-count / IL giredhi sarudzo.
Jacket ruvara: aqua (OM3), Erika Violet (OM4), lime green (OM5), yero (OS2), tsika RAL.
Breakout mudzi kudzivirira: hapana (kumhanya kupfupi), naironi boot (standard rack), rakarukwa sleeve (kupfeka kwepamusoro).
OEM label uye kudhinda: pane connector body, PE bag uye master carton.
Custom packaging: PE bhegi uye katoni dhizaini pane yako artwork, MOQ 30,000 pcs for full custom packaging run.
Samples: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.
Mibvunzo Inowanzo bvunzwa
Q1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Q2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100G, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Q3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100G / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / SC / FC on the other?
Ehe. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
Q5. Are both ends symmetric on MPO-to-MPO breakout cables?
Ehe. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. Kusvika pa 6 MPO connectors per single end are supported.
Q6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100GSR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; isu tinotumira Type A / B / C maererano nemari yako yezvinhu.
Q7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 dB. Ultra low-loss builds with Japanese ferrules reach 0.15 dB per single fiber. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
Q8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
Ehe. Every cable and every fiber core is tested for insertion loss, kudzokera kurasikirwa, kuguma-chiso geometry, polarity, fiber sequence, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
Q9. Ndinogona here kuwana samples ndisati ndaisa odha yakawanda?
Ehe. Yemahara diki-huwandu samples inopihwa kuti ionekwe yemhando; unongovhara mari yekutumira, uye iyo mari yekutumira inobviswa kubva kune yako yekutanga yepamutemo yakawanda odha serubatsiro rwekubatana.
Q10. Ndeipi yako yemwedzi kugona uye yakajairika nguva yekutungamira?
Mwedzi unobuda mhiri kweMPO mhuri ndeye 150,000 zvimedu. Yakajairwa maodha ezviuru akati wandei zvidimbu ngarava mumazuva 7-12 kubva kustock. Mahodha akawanda pamusoro 20,000 zvidimbu zvinotakura mumazuva 15-20. Tsika yekurongedza ine yakazara artwork inomhanya kubva kuMOQ ye 30,000 pcs.
Q11. Zvigadzirwa zveMPO izvi zvinogona kushandiswa kunze?
Iyo yakajairwa MPO mutsara yakagadziridzwa kune data hall, MDA uye rack nharaunda (IP50, −20°C to +60°C, LSZH). Zvekunze uye FTTA application, shandisa FTTA MPO/MTP Fiber Optic Patch Cord nebhachi rekunze, kana kukumbira chivakwa chekunze chekunze. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. What is the warranty?
Standard warranty is 1 gore; design service life is up to 10 makore. Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.
Tichapindura mukati 12 maawa, ndapota teerera kune email ine suffix "@fibconet.com".
Zvakare, unogona kuenda ku Contact Peji, iyo inopa fomu rakadzama.