Фибцонет производи 10 series of МПО / MTP fiber optic products for 40G, 100Г, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.
Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 комада across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 дБ on assemblies built with Japanese-imported ferrules, and to typical 0.20–0.35 dB on standard builds with domestic Sanhuan ferrules.
Every finished cable is 100% inspected for insertion loss, повратни губитак, end-face geometry, поларитет, секвенца влакана, дужина и изглед. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 МПО / MTP Products We Manufacture
Група 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.
Модел
Фибер Цоунт
Интерфејс
Typical Use
Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 до 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion
12/24 Основни МПО касетни модул високе густине
12 или 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base
8/12/24 МПО МТП База за 24 ЛЦ Ултра Хигх Денсити 1У Модулар
До 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows
Група 2 — Rack Patch Panels
Empty or pre-assembled 1U 19-inch chassis to hold cassette modules and to organise trunk cables at the top of the rack.
Модел
Rack Size
Loading
Typical Use
Data Center 19-inch Standard Rack MPO Patch Panel
1У
Empty chassis for cassettes
Standard MDA rack, modular build
Pre-assembled 1U 19-inch Rack LC MTP®/MPO Patch Panel
1У
Pre-terminated LC front, MPO back
Plug-and-play rack, no field assembly
Група 3 — Patch Cords and Trunk Cables
The physical link between MPO cassettes, патцх панели, transceivers and MPO backbone runs.
Модел
Структура
Fiber Options
Typical Use
Factory Pre-termination MPO-MPO 3.0mm LSZH Patch Cord / Trunk Cable
MPO to MPO
ОС2 / ОМ3 / ОМ4 / ОМ5
Backbone trunk, MDA to EDA
Оптички кабл за МПО МТП конектор
MPO to MPO
ОС2 / ОМ3 / ОМ4 / ОМ5
Rack-to-rack short jumper
FTTA MPO/MTP Fiber Optic Patch Cord Cable
MPO to MPO, outdoor jacket
ОС2 / ОМ3 / ОМ4
Base station FTTA and outdoor short link
Група 4 — Loopback
Used to test transceiver ports, cassette continuity and rack integrity without pulling a full trunk link.
Модел
Интерфејс
Влакно
Typical Use
OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
ОМ3 мултимоде
Multimode transceiver and cassette test
Група 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.
Модел
Одговара
Typical Use
Средство за чишћење свих типова МПО/МТП
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit
What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
МПО (Пусх Он са више влакана) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Both mate with each other and both follow the same fiber count and polarity rules. Fibconet manufactures to the MPO standard and supplies MTP-compatible builds on request; the underlying optical spec is identical.
Polarity — Type A, Тип Б, Тип Ц
Поларитет
Fiber Sequence
Typical Use
Тип А (Право)
1↔1, 2↔2 … 12↔12 straight-through
Point-to-point trunks with A-to-B duplex crossover in the patch cord
Тип Б (Reverse)
1↔12, 2↔11 … 12↔1 fully reversed
Direct connection to SFP+ / QSFP transceivers; most common for 40G/100G breakout
Тип Ц (Pair-swap)
Adjacent pairs swapped: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling
Polarity errors are the single most common cause of link-up failure on MPO systems. Confirm polarity at RFQ stage; we ship Type A / Б / C per your bill of materials.
Gender — Male (with pins) vs Female (no pins)
Male: two guide pins protrude from the end-face. Used at fixed / patch-panel ends.
Female: no pins, two guide-pin holes only. Used at the equipment / movable-jumper end.
Wrong gender at RFQ = the entire batch has to be re-terminated. Always specify Male-Female, Female-Female or Male-Male at the quotation stage.
Fiber Type — Match to Data Rate and Distance
Влакно
Таласна дужина
10G reach
40Г / 100G reach
Typical Use
ОМ3 мултимоде
850 нм
550 м
100 м / 100 м (SR4)
Short rack-to-rack, cost-sensitive builds
OM4 multimode
850 нм
550 м
150 м / 150 м (SR4)
Standard data-center backbone
OM5 multimode
850 & 953 nm SWDM
550 м
≥ 150 м; supports 400G SR4.2
AI cluster and next-gen supercompute backbone
OS2 singlemode
1310 / 1550 нм
10 км +
10 км + (ЛР4 / DR4)
Inter-building, кампуса, DCI long-haul
Insertion Loss Grade — Standard vs Low-Loss
Оцена
Max IL per mated pair
Повратни губитак
Typical Use
Стандард (SM APC)
≤ 0.70 дБ
≥ 55 дБ
Enterprise LAN, standard data-center runs
Low-Loss / Елите (SM APC)
≤ 0.35 дБ (типично 0.25 дБ)
≥ 55 дБ
Cabinet-to-cabinet 100G high-density backbone
Ultra Low-Loss (Japanese ferrule)
0.15 dB per single fiber
≥ 55 дБ
400Г / 800G AI backbone; long link budgets
Стандард (MM PC)
≤ 0.50 дБ
≥ 20 дБ
OM3/OM4 short data-center runs
Low-Loss (MM PC)
≤ 0.35 дБ (типично 0.20 дБ)
≥ 20 дБ
OM4/OM5 high-density backbone
Техничке спецификације
Белешка: the values below are family-typical across the 10 серије, није листа података са једним СКУ. Ask us for the model-specific test report at RFQ stage; шаљемо га под бројем дела модела.
Параметар
Типична вредност
Коментар
Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone
Тип влакана
ОС2 (Г.652.Д, G.657.A1/A2), ОМ3, ОМ4, ОМ5
G.657.A2 for tight-radius rack routing
Поларитет
Тип А / Тип Б / Тип Ц
Type B is default for 40G/100G breakout
Пол
Male (with pins) / Female (no pins)
Both ends selectable per port
End-face polish
АПЦ (синглемоде) / ПЦ (мултимоде)
APC green, PC beige/aqua
Губитак уметања (једно влакно)
0.15 – 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules
Повратни губитак
≥ 55 дБ (SM APC), ≥ 45 дБ (SM PC), ≥ 20 дБ (MM PC)
Трајност парења
≥ 500 циклуса, IL drift ≤ 0.2 дБ
Guide-pin positioning with elastic pre-load
Минимални радијус савијања
MPO end ≥ 30 мм; LC breakout end ≥ 20 мм
Статично 15 мм, динамичан 30 mm on G.657.A2 fiber
Радна температура
−20°C to +60°C
Optical performance stable across the range
Ingress / влажност
IP50; 45°Ц / 95% РХ; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed
Length range
0.2 до 300 m custom; · Лако се монтира са механичким спојем и без полирања
· Минимизирајте стопу кварова помоћу карактеристика уклањања и поновне употребе 0.5 до 30 м
Per model
Trunk cable OD
3.0 mm typical (8/12/16/24Ф); ~5.0 mm (48Ф)
Higher fiber count = larger OD
Јакна
LSZH standard; ОФНР / OFNP on request
Suitable for data hall, riser and plenum
Тест таласне дужине
1310 / 1550 нм (СМ), 850 / 1300 нм (ММ)
Гаранција
1 године; design life up to 10 године
Field replacement covered within warranty period
Производне способности и контрола квалитета
Production Line and Monthly Capacity
Надређена операција Фибцонета у оптичким пасивним компонентама датира од 1994. МПО / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 комада. Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
Upstream Material Control
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. We control the upstream stack rather than only the assembly step:
Ферулес: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
Влакно: ИОФЦ / Фиберхоме / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
Арамидно предиво: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.
100% Инспекција квалитета
Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
Поларитет и редослед влакана: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.
Сертификати и усклађеност
Fibconet operates under an integrated ИСО 9001 / ИСО 14001 / ИСО 45001 management system covering quality, environment and occupational health & сигурност. Raw-material RoHS reports ship by default. Product-level compliance — CE, REACH, тхе, ETL — is issued per model and per target market. Certification applicability varies by product and project requirements. Send us your target market and the model list; we return the applicable certificate set with the quotation.
Паковање, OEM and Custom Options
Standard Packaging
Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, количина, polarity and gender code.
OEM and Custom Options
Дужина: any length from 0.2 м то 300 м, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 центиметар) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3×8 / 4×6; 16F to 2×8; 48F to 6×8; све до 6 MPO connectors per single end on MPO-to-MPO breakouts.
Поларитет: Тип А / Б / C per port; internal crossover on Type B for direct SFP mating.
Ferrule grade: domestic Sanhuan or Japanese-imported per fiber-count / IL grade selection.
Боја јакне: акуа (ОМ3), erika violet (ОМ4), зелена лимете (ОМ5), жута (ОС2), custom RAL.
Breakout root protection: ниједан (short runs), nylon boot (standard rack), braided sleeve (high-wear).
OEM label and printing: on connector body, PE bag and master carton.
Прилагођено паковање: PE bag and carton design per your artwork, МОК 30,000 pcs for full custom packaging run.
Узорци: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.
Често постављана питања
К1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
К2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100Г, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
К3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100Г / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
К4. Can I mix ends — MPO on one side and LC / СЦ / FC on the other?
да. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
К5. Are both ends symmetric on MPO-to-MPO breakout cables?
да. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. До 6 MPO connectors per single end are supported.
К6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100G SR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; we ship Type A / Б / C per your bill of materials.
К7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 дБ. Ultra low-loss builds with Japanese ferrules reach 0.15 dB per single fiber. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
К8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
да. Every cable and every fiber core is tested for insertion loss, повратни губитак, end-face geometry, поларитет, секвенца влакана, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
К9. Can I get samples before placing a bulk order?
да. Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
К10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 комада. Standard orders of several thousand pieces ship in 7–12 days from stock. Bulk orders above 20,000 pieces ship in 15–20 days. Custom packaging with full artwork runs from an MOQ of 30,000 ком.
Q11. Can these MPO products be used outdoors?
The standard MPO line is optimised for data hall, MDA and rack environments (IP50, −20°C to +60°C, ЛСЗХ). For outdoor and FTTA applications, use the FTTA MPO/MTP Fiber Optic Patch Cord with an outdoor jacket, or ask for a custom outdoor build. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. What is the warranty?
Standard warranty is 1 године; design service life is up to 10 године. Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.
Одговорићемо унутар 12 сати, обратите пажњу на имејл са суфиксом “@фибцонет.цом”.