











Pabrikan Fibconet 12 runtuyan outdoor panutupanana sambungan serat optik (disebut oge closures gabungan, panutupanana kabel, atawa dina basa gaul kaléng kubah) pikeun OSP splicing antara feeder, distribusi sareng kabel serelek. Kapasitas dibasajankeun 12 cores pikeun FTTH serelek junctions nepi ka 840 inti pikeun tulang tonggong jeung titik splice jarak jauh. Disegel ka IP68, perumahan anu PP + GF, PPR atawa polimér logam-braced kalawan a 15 mun 25-taun hirup widang desain. Akar komponén optik pasip urang ngabasmi deui ka 1994, sareng alat-alat internal anu sami sareng disiplin tés anu diwangun pikeun pamisah PLC ayeuna ngajalankeun garis panutupanana splice.

Dua jinis awak nutupan dua metode pamasangan OSP: kubah (nangtung) panutupanana pikeun kutub, témbok jeung sendi langsung-dikubur, jeung horisontal (baris) panutupanana pikeun manhole, handhole jeung angka-8 titik splice hawa. Model kubah anu dipilih dikirimkeun sateuacana sareng 1 × 8 atanapi 1 × 16 PLC splitter sareng janten titik hub PON di jero ODN Gancang / deployment FTTH pre-terminated. Enclosures nampi mékanis, panas-ngaleutikan atawa silicone sealing per model.
Bagian handap daptar daptar 12 model dikelompokkeun ku tipe awak, teras nutupan logika pamilihan Kubah-vs-Horizontal, spésifikasi teknis, kamampuan manufaktur, bungkusan, FAQ, jeung saluran cutatan.
Awak silinder sareng pelat dasar tunggal anu mawa sadaya palabuhan kabel. Pangalusna cocog pikeun pole-mount, témbok-pasang sareng sambungan langsung-dikubur dimana kabel asup ti hiji tungtung. Dua model splitter-sarat handap ganda salaku titik hub PON jero hiji deployment ODN Gancang.
| Modél | Kapasitas Inti | Ngégél / Peunteun | peran hub PON | Paké has |
|---|---|---|---|---|
| IK10 IP68 96 Penutupan Terminal Aksés Core Huawei-cocog | 96 intina | IP68 / Pangaruh IK10 | — | Huawei-standard access node, pole or wall |
| 96/144 Core Dome Closure (Kutub / Tembok / Underground) | 96–144 cores | IP68 | — | Multi-scenario OSP splice, any mount |
| 96/144 Inti 100 kPa 25-Year Splice Closure | 96–144 cores | IP68 / 100 kPa air-pressure hold | — | Long-life backbone joints requiring pressure test |
| 144 Core Metal-Bracket IP68 Dome Closure | 144 intina | IP68 | — | Metal-braced tray for high-vibration or heavy cable load |
| IP68 288 Core High-capacity Dome Closure | 288 intina | IP68 | — | High-density backbone splice point |
| 1:8 / 1:16 PLC Splitter IP68 Dome (22000 N / 10 cm cable retention) | Splitter-loaded dome | IP68 / 22000 N cable pull | Yes — Quick ODN hub | PON hub combining splice and 1×8 or 1×16 splitting |
| IP68 1:8 PLC Splitter Pre-terminated FAT Closure | Koritter + FAT ports | IP68 | Yes — pre-terminated PON hub | Plug-and-play PON hub with drop-cable ports |
Elongated body with cable ports at both ends. Preferred for manhole, handhole, aerial figure-8 span and any splice point where cables enter and exit in the same axis.
| Modél | Kapasitas Inti | Ngégél / Peunteun | Paké has |
|---|---|---|---|
| PP+GF / PPR IN-LINE 2-in-2-out 12 Goréng Gancang | 12 intina | IP68 / mechanical seal | FTTH drop junction, aerial or handhole |
| 48 Core 1-in-2-out Inline Cable Closure | 48 intina | IP68 | Small branch inline splice |
| 15+ Service Years PP+GF IP68 2-in-2-out Inline Closure | Nepi ka 96 intina | IP68 / 15+ years field life | Mid-density distribution splice with long life claim |
| 96 Core Silicone-Protection Horizontal Splice Closure (Disaluyukeun) | 96 intina | IP68 / silicone sealing | Manhole splice with elevated moisture and chemical exposure |
| 576 / 840 Core Heat-Shrink Seal IP68 Cable Closure | 576–840 cores | IP68 / heat-shrink | Long-haul backbone splice, high-count ribbon or loose-tube |
A splice closure protects, seals and organises spliced fibers at any point along an OSP cable route. The body shape follows the physical install location, not the fiber count.
| Dome (Nangtung) | Horizontal (Inline) | |
|---|---|---|
| Cable entry | All ports on one base plate | Ports at two opposite ends |
| Best install | Kutub, témbok, Direct-dikubur, hand-hole from top | Lubang, aerial figure-8 span, tray-mount inline |
| Typical core count | 96, 144, 288 — expandable via added trays | 12, 48, 96, 576, 840 — scales with body length |
| Access | Lift the dome, all splice trays exposed | Split the shell, access trays along the axis |
| PLC splitter loading | Common (peran hub PON) | Less common, used mainly for pure splice |

| Core capacity | Network role | Body type shortlist |
|---|---|---|
| 12–48 cores | FTTH drop / distribution junction | Inline, mechanical seal |
| 96 intina | Access-layer PON node, base-station splice | Dome (Huawei-compatible or metal-bracket) |
| 144 intina | Distribution-layer aggregation | Dome, baki-expandable |
| 288 intina | titik sambungan tulang tonggong Metro | Dome, K kapasitas tinggi |
| 576–840 cores | Tulang tonggong lila-haul, pita luhur-count | Inline, segel panas-nyusut |
Catetan: nilai handap mangrupakeun rentang kulawarga-khas sakuliah 12 runtuyan, lain lembar data SKU tunggal. Tanya kami pikeun laporan tés modél-spésifik dina tahap RFQ; kami ngirimkeunana handapeun nomer bagian modél.
| Parameter | Nilai khas | mairan |
|---|---|---|
| Core capacity | 12 ka 840 intina | Per modél; expandable via trays splice ditambahkeun |
| Bahan perumahan | PP+GF, PPR, ABS + PC atanapi polimér logam-braced | Dipilih per modél sareng lingkungan |
| Kelas sealing | IP68 | Sadaya model OSP outdoor |
| Résistansi dampak | Nepi ka IK10 dina modél anu dipilih | Metal-bracket jeung runtuyan IK10-dipeunteun |
| Métode sealing | Mékanis / heat-shrink / silikon | Per modél |
| Tahan tekanan hawa | 100 kPa dina modél anu dipilih | Pikeun jaringan OSP pressurized |
| Panahan kabel (tarik axial) | Nepi ka 22,000 N / 10 cm dina modél anu dipilih | kubah Splitter-sarat dipeunteun pikeun tarikan beurat |
| palabuhan Éntri kabel | 1-asup-2-kaluar, 2-asup-2-kaluar, 4-asup-4-kaluar per modél | palabuhan tambahan sadia on custom ngawangun |
| Diaméter kabel utama | Biasana Φ7–Φ16 mm | Model-gumantung; branch cable Φ5–Φ11.5 mm |
| Nampan sambungkeun | Stackable, 12 atawa 24 splices per tray | Both fusion and mechanical splice trays supported |
| Suhu operasi | −40°C to +65°C | Storage −35°C to +55°C per shipping spec |
| Design field life | 15 ka 25 years outdoor | Per modél; PP+GF with UV additive supports 25 taun |
| Reference test standards | IEC 61753-1, YD/T 814, GR-771 | Applied per project requirement |
Fibconet’s optical communication background traces back to the early 1990s. Our passive optical component manufacturing roots start in 1994 with a PLC splitter factory; the company was formally structured in 2000 and today operates with 300+ core staff and an extended multi-site manufacturing network of up to 800 staf jeung insinyur across China. The same tooling and test discipline built for high-count PLC splitter production now runs the splice closure line, including injection molding of PP+GF and PPR housings, splice tray forming, and full-load assembly.
Splice closures are only as reliable as the materials inside them. Urang ngadalikeun tumpukan hulu tinimbang ukur hambalan assembly:

Fibconet operates under an integrated ISO 9001 / ISO 14001 / ISO 45001 sistem manajemen ngawengku kualitas, kaséhatan lingkungan sareng padamelan & kaamanan. Raw material RoHS reports are supplied by default with every shipment.
Product-level compliance is issued per model and per target market. Depending on the model list and destination country, we can support IEU, RoHS, REACH, éta, Bijon aci, CPR, ANATEL, CCA, TLC and other market-entry documents. Applicable test reports against IEC 61753-1, YD/T 814 jeung Telcordia GR-771 standar rujukan disadiakeun dina skala proyék.
Larapkeun sertifikasi beda-beda dumasar kana syarat produk sareng proyék. Kirimkeun kami target pasar anjeun sareng daptar modél, sarta kami balik sertipikat lumaku diatur kalawan cutatan.
All four are the same product family — an outdoor enclosure that houses and seals spliced fibers along an OSP cable route. “Splice closure” jeung “joint closure” are the standard English terms. “Dome can” jeung “炮筒” are field slang for the dome (nangtung) body style. The Chinese term “熔接包” ngarujuk kana kategori anu sami sareng umum dina RFQ basa Cina ti Asia Tenggara sareng Afrika.
Panutupan splice ngajaga sareng ngatur serat spliced sapanjang jalur kabel OSP; teu aya terminasi kabel serelek aktip pikeun palanggan. Hiji kotak distribusi (GEMIK) terminates kabel serelek kana palabuhan adaptor sarta mindeng imah splitter panungtungan-mil. Closures splice diuk deeper dina jaringan; kotak distribusi linggih di titik serelek pangdeukeutna ka imah.
Pilih kubah nalika kabel asup ti hiji arah - kutub-Gunung, témbok-gunung, Direct-dikubur, atawa leungeun-liang diakses ti luhur. Pilih inline nalika kabel asup sareng kaluar sapanjang sumbu anu sami - splice manhole, aerial figure-8 span, atawa baki-Gunung sapanjang jalan linier.
Match the closure to the largest cable at the splice point plus a spare tray for future expansion. FTTH drop junctions typically use 12–48 core inline closures. PON access nodes use 96–144 core dome closures. Metro backbone splices use 288 intina; long-haul trunk splices use 576 atawa 840 cores in heat-shrink inline bodies.
For direct-buried and pressurised networks, use a mechanical-seal dome with 100 kPa air-pressure hold; the seal is verifiable in the field and re-enterable for future splice work. Heat-shrink is more permanent but not re-enterable without cutting.
Nuhun. Dome closures can be shipped with a 1×8 or 1×16 PLC splitter pre-terminated at factory. The 1:8 / 1:16 PLC Splitter Dome model is rated for 22,000 N / 10 cm cable retention so the housing tolerates heavy drop-cable pull. Splitter chips are Shijia or Korean-source, and pigtails use G.657.A2 fiber from major Chinese fiber brands.
PP+GF and PC+ABS housings with a UV stabiliser additive package hold 15 ka 25 years of outdoor service, depending on model. Ask us for the specific model’s material spec if your project tender requires a stated design life.
Nuhun. IEC 61753-1, YD/T 814 and GR-771 test reports are available per model. Raw material RoHS reports ship by default. Market-entry certificates such as CE, REACH, éta, Bijon aci, CPR, ANATEL, CCA and TLC are issued per model and per target market. If a certificate you need is not already on file, we can arrange third-party testing at project scale.
MOQ starts at 100 pcs on standard configuration; custom builds are typically 500–1,000 pcs. Standard orders ship in 15–25 days; custom builds in 25–40 days. [TBC: confirm exact values per model at RFQ stage.]
Nuhun. Pole-mount and wall-mount hardware is included on the dome closures. Aerial figure-8 mounting kits for inline closures are supplied on request. Manhole tray mounts and cable-management brackets are quoted with the closure.
Nuhun. Our splitter-loaded dome closures — the 1:8 / 1:16 PLC Splitter Dome and the pre-terminated FAT closure — act as PON hub points inside a Quick ODN system. Aranjeunna dipasangkeun sareng kabel serelek anu tos réngsé, hub MPO, kotak sub sareng pamisah asimétri pikeun ngirangan splicing dina situs, motong tanaga gawé instalasi, sarta nyieun rollout FTTH leuwih bisa diprediksi. Upami proyék anjeun mangrupikeun FTTH énggal dina pasar anu sénsitip biaya tenaga kerja, ménta konfigurasi ODN Gancang cocog mun anjeun ngirim RFQ.
Urang bakal ngabales dina 12 jam, punten perhatoskeun email anu nganggo sufiks “@fibconet.com”.
oge, anjeun tiasa angkat ka Kaca Kontak, nu nyadiakeun formulir leuwih lengkep.