மொழிபெயர்ப்பைத் திருத்து
தேடு

MPO தொடர்

எம்.பி.ஓ / MTP Data Center Cabling Manufacturer — Cassettes, Patch Panels, Trunk Cables and Patch Cords
Fibconet உற்பத்தி செய்கிறது 10 series of எம்.பி.ஓ / MTP fiber optic products for 40G, 100ஜி, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.

Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 துண்டுகள் across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 dB on assemblies built with Japanese-imported ferrules, and to typical 0.20–0.35 dB on standard builds with domestic Sanhuan ferrules.

Every finished cable is 100% inspected for insertion loss, இழப்பு திரும்ப, end-face geometry, துருவமுனைப்பு, ஃபைபர் வரிசை, length and appearance. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 எம்.பி.ஓ / MTP Products We Manufacture
குழு 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.

மாதிரி
ஃபைபர் எண்ணிக்கை
இடைமுகம்
வழக்கமான பயன்பாடு

Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 செய்ய 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion

12/24 கோர் உயர் அடர்த்தி தீர்வு MPO கேசட் தொகுதி
12 அல்லது 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base

8/12/24 MPO MTP அடிப்படை 24 எல்.சி அல்ட்ரா உயர் அடர்த்தி 1 யூ மட்டு
வரை 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows

குழு 2 — Rack Patch Panels
கேசட் தொகுதிகளை வைத்திருக்க மற்றும் ரேக்கின் மேற்புறத்தில் டிரங்க் கேபிள்களை ஒழுங்கமைக்க வெற்று அல்லது முன் கூட்டப்பட்ட 1U 19-இன்ச் சேஸ்.

மாதிரி
ரேக் அளவு
ஏற்றுகிறது
வழக்கமான பயன்பாடு

தரவு மையம் 19-இன்ச் ஸ்டாண்டர்ட் ரேக் MPO பேட்ச் பேனல்
1யு
கேசட்டுகளுக்கான வெற்று சேஸ்
நிலையான MDA ரேக், மட்டு உருவாக்கம்

முன்-அசெம்பிள் செய்யப்பட்ட 1U 19-இன்ச் ரேக் LC MTP®/MPO பேட்ச் பேனல்
1யு
முன் நிறுத்தப்பட்ட LC முன், மீண்டும் MPO
பிளக்-அண்ட்-ப்ளே ரேக், கள சட்டசபை இல்லை

குழு 3 - இணைப்பு வடங்கள் மற்றும் ட்ரங்க் கேபிள்கள்

MPO கேசட்டுகளுக்கு இடையிலான உடல் இணைப்பு, இணைப்பு பேனல்கள், டிரான்ஸ்சீவர்கள் மற்றும் MPO முதுகெலும்பு இயங்குகிறது.

மாதிரி
கட்டமைப்பு
ஃபைபர் விருப்பங்கள்
வழக்கமான பயன்பாடு

ஃபேக்டரி ப்ரீ-டெர்மினேஷன் MPO-MPO 3.0mm LSZH பேட்ச் கார்டு / டிரங்க் கேபிள்
MPO முதல் MPO வரை
OS2 / OM3 / OM4 / OM5
முதுகெலும்பு தண்டு, MDA முதல் EDA வரை

ஃபைபர் ஆப்டிக் எம்பிஓ எம்டிபி கனெக்டர் பேட்ச் கார்டு
MPO முதல் MPO வரை
OS2 / OM3 / OM4 / OM5
ரேக்-டு-ரேக் ஷார்ட் ஜம்பர்

FTTA MPO/MTP ஃபைபர் ஆப்டிக் பேட்ச் கார்ட் கேபிள்
MPO முதல் MPO வரை, வெளிப்புற ஜாக்கெட்
OS2 / OM3 / OM4
அடிப்படை நிலையம் FTTA மற்றும் வெளிப்புற குறுகிய இணைப்பு

குழு 4 - லூப்பேக்
டிரான்ஸ்ஸீவர் போர்ட்களை சோதிக்கப் பயன்படுகிறது, cassette continuity and rack integrity without pulling a full trunk link.

மாதிரி
இடைமுகம்
நார்ச்சத்து
வழக்கமான பயன்பாடு

OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
OM3 மல்டிமோட்
Multimode transceiver and cassette test

குழு 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.

மாதிரி
பொருந்துகிறது
வழக்கமான பயன்பாடு

அனைத்து வகைகளும் பொருத்தும் MPO/MTP கிளீனர்
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit

What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
எம்.பி.ஓ (மல்டி-ஃபைபர் புஷ் ஆன்) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Both mate with each other and both follow the same fiber count and polarity rules. Fibconet manufactures to the MPO standard and supplies MTP-compatible builds on request; the underlying optical spec is identical.
Polarity — Type A, வகை பி, வகை C

துருவமுனைப்பு
Fiber Sequence
வழக்கமான பயன்பாடு

வகை A (Straight)
1↔1, 2↔2 … 12↔12 straight-through
Point-to-point trunks with A-to-B duplex crossover in the patch cord

வகை பி (Reverse)
1↔12, 2↔11 … 12↔1 fully reversed
Direct connection to SFP+ / QSFP transceivers; most common for 40G/100G breakout

வகை C (Pair-swap)
Adjacent pairs swapped: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling

Polarity errors are the single most common cause of link-up failure on MPO systems. Confirm polarity at RFQ stage; we ship Type A / பி / C per your bill of materials.
Gender — Male (with pins) vs Female (ஊசிகள் இல்லை)

ஆண்: two guide pins protrude from the end-face. Used at fixed / patch-panel ends.
Female: ஊசிகள் இல்லை, two guide-pin holes only. Used at the equipment / movable-jumper end.

Wrong gender at RFQ = the entire batch has to be re-terminated. Always specify Male-Female, Female-Female or Male-Male at the quotation stage.
Fiber Type — Match to Data Rate and Distance

நார்ச்சத்து
அலைநீளம்
10G reach
40ஜி / 100G reach
வழக்கமான பயன்பாடு

OM3 மல்டிமோட்
850 nm
550 மீ
100 மீ / 100 மீ (SR4)
Short rack-to-rack, cost-sensitive builds

OM4 multimode
850 nm
550 மீ
150 மீ / 150 மீ (SR4)
Standard data-center backbone

OM5 multimode
850 & 953 nm SWDM
550 மீ
≥ 150 மீ; supports 400G SR4.2
AI cluster and next-gen supercompute backbone

OS2 singlemode
1310 / 1550 nm
10 கி.மீ +
10 கி.மீ + (LR4 / DR4)
Inter-building, வளாகம், DCI long-haul

Insertion Loss Grade — Standard vs Low-Loss

தரம்
Max IL per mated pair
வருவாய் இழப்பு
வழக்கமான பயன்பாடு

தரநிலை (SM APC)
≤ 0.70 dB
≥ 55 dB
Enterprise LAN, standard data-center runs

Low-Loss / எலைட் (SM APC)
≤ 0.35 dB (வழக்கமான 0.25 dB)
≥ 55 dB
Cabinet-to-cabinet 100G high-density backbone

Ultra Low-Loss (Japanese ferrule)
0.15 dB per single fiber
≥ 55 dB
400ஜி / 800G AI backbone; long link budgets

தரநிலை (MM PC)
≤ 0.50 dB
≥ 20 dB
OM3/OM4 short data-center runs

Low-Loss (MM PC)
≤ 0.35 dB (வழக்கமான 0.20 dB)
≥ 20 dB
OM4/OM5 high-density backbone

தொழில்நுட்ப விவரக்குறிப்புகள்

குறிப்பு: the values below are family-typical across the 10 தொடர், ஒரு SKU தரவுத்தாள் அல்ல. RFQ கட்டத்தில் மாதிரி-குறிப்பிட்ட சோதனை அறிக்கையை எங்களிடம் கேளுங்கள்; நாங்கள் அதை மாதிரி பகுதி எண்ணின் கீழ் அனுப்புகிறோம்.

அளவுரு
வழக்கமான மதிப்பு
கருத்து

Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone

ஃபைபர் வகை
OS2 (ஜி.652.டி, G.657.A1/A2), OM3, OM4, OM5
G.657.A2 for tight-radius rack routing

துருவமுனைப்பு
வகை A / வகை பி / வகை C
Type B is default for 40G/100G breakout

பாலினம்
ஆண் (with pins) / Female (ஊசிகள் இல்லை)
Both ends selectable per port

End-face polish
APC (ஒற்றை முறை) / பிசி (பலமுறை)
APC green, PC beige/aqua

உள்ளிடலில் இழப்பு (ஒற்றை இழை)
0.15 – 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules

வருவாய் இழப்பு
≥ 55 dB (SM APC), ≥ 45 dB (SM PC), ≥ 20 dB (MM PC)

இனச்சேர்க்கை ஆயுள்
≥ 500 சுழற்சிகள், IL drift ≤ 0.2 dB
Guide-pin positioning with elastic pre-load

குறைந்தபட்ச வளைவு ஆரம்
MPO end ≥ 30 மிமீ; LC breakout end ≥ 20 மிமீ
நிலையான 15 மிமீ, மாறும் 30 mm on G.657.A2 fiber

இயக்க வெப்பநிலை
−20°C to +60°C
Optical performance stable across the range

Ingress / ஈரப்பதம்
IP50; 45. C. / 95% RH; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed

Length range
0.2 செய்ய 300 m custom; · மெக்கானிக்கல் ஸ்ப்லைஸுடன் அசெம்பிள் செய்ய எளிதானது மற்றும் மெருகூட்டல் இல்லை · நீக்குதல் மற்றும் மீண்டும் பயன்படுத்தக்கூடிய அம்சங்களின் மூலம் குறைபாடு விகிதத்தைக் குறைக்கவும் 0.5 செய்ய 30 மீ
மாதிரிக்கு

Trunk cable OD
3.0 mm typical (8/12/16/24எஃப்); ~5.0 mm (48எஃப்)
Higher fiber count = larger OD

ஜாக்கெட்
LSZH standard; OFNR / OFNP on request
Suitable for data hall, riser and plenum

Test wavelength
1310 / 1550 nm (எஸ்.எம்), 850 / 1300 nm (எம்.எம்)

உத்தரவாதம்
1 ஆண்டு; design life up to 10 ஆண்டுகள்
Field replacement covered within warranty period

உற்பத்தி திறன் மற்றும் தரக் கட்டுப்பாடு
Production Line and Monthly Capacity
Fibconet’s parent operation in optical passive components dates back to 1994. எம்.பி.ஓ / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 துண்டுகள். Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
அப்ஸ்ட்ரீம் பொருள் கட்டுப்பாடு
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. அசெம்பிளி படியை மட்டும் கட்டுப்படுத்தாமல் அப்ஸ்ட்ரீம் ஸ்டேக்கை கட்டுப்படுத்துகிறோம்:

ஃபெரூல்ஸ்: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
நார்ச்சத்து: YOFC / ஃபைபர்ஹோம் / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
அராமிட் நூல்: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.

100% தர ஆய்வு

Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
Polarity and fiber sequence: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.

சான்றிதழ்கள் மற்றும் இணக்கம்
Fibconet ஒரு ஒருங்கிணைந்த கீழ் செயல்படுகிறது ஐஎஸ்ஓ 9001 / ஐஎஸ்ஓ 14001 / ஐஎஸ்ஓ 45001 தரத்தை உள்ளடக்கிய மேலாண்மை அமைப்பு, சுற்றுச்சூழல் மற்றும் தொழில் ஆரோக்கியம் & பாதுகாப்பு. Raw-material RoHS reports ship by default. Product-level compliance — CE, அடையுங்கள், தி, ETL — is issued per model and per target market. தயாரிப்பு மற்றும் திட்டத் தேவைகளைப் பொறுத்து சான்றிதழ் பொருந்தக்கூடிய தன்மை மாறுபடும். உங்கள் இலக்கு சந்தை மற்றும் மாதிரி பட்டியலை எங்களுக்கு அனுப்பவும்; we return the applicable certificate set with the quotation.
பேக்கேஜிங், OEM மற்றும் தனிப்பயன் விருப்பங்கள்
Standard Packaging

Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, அளவு, polarity and gender code.

OEM மற்றும் தனிப்பயன் விருப்பங்கள்

நீளம்: any length from 0.2 m to 300 மீ, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 செ.மீ) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3× 8 / 4× 6; 16F to 2×8; 48F to 6×8; அது வரை 6 MPO connectors per single end on MPO-to-MPO breakouts.
துருவமுனைப்பு: வகை A / பி / C per port; internal crossover on Type B for direct SFP mating.
Ferrule grade: domestic Sanhuan or Japanese-imported per fiber-count / IL grade selection.
Jacket color: அக்வா (OM3), erika violet (OM4), சுண்ணாம்பு பச்சை (OM5), மஞ்சள் (OS2), custom RAL.
Breakout root protection: எதுவும் இல்லை (short runs), nylon boot (standard rack), braided sleeve (high-wear).
OEM label and printing: on connector body, PE bag and master carton.
Custom packaging: PE bag and carton design per your artwork, MOQ 30,000 pcs for full custom packaging run.
மாதிரிகள்: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.

அடிக்கடி கேட்கப்படும் கேள்விகள்
Q1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Q2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100ஜி, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Q3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100ஜி / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / எஸ்சி / FC on the other?
ஆம். MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
Q5. Are both ends symmetric on MPO-to-MPO breakout cables?
ஆம். For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. வரை 6 MPO connectors per single end are supported.
Q6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100GSR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; we ship Type A / பி / C per your bill of materials.
Q7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 dB. Ultra low-loss builds with Japanese ferrules reach 0.15 dB per single fiber. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
Q8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
ஆம். Every cable and every fiber core is tested for insertion loss, இழப்பு திரும்ப, end-face geometry, துருவமுனைப்பு, ஃபைபர் வரிசை, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
Q9. Can I get samples before placing a bulk order?
ஆம். Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
Q10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 துண்டுகள். Standard orders of several thousand pieces ship in 7–12 days from stock. Bulk orders above 20,000 pieces ship in 15–20 days. Custom packaging with full artwork runs from an MOQ of 30,000 பிசிக்கள்.
Q11. Can these MPO products be used outdoors?
The standard MPO line is optimised for data hall, MDA and rack environments (IP50, −20°C to +60°C, LSZH). For outdoor and FTTA applications, use the FTTA MPO/MTP Fiber Optic Patch Cord with an outdoor jacket, or ask for a custom outdoor build. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. What is the warranty?
Standard warranty is 1 ஆண்டு; design service life is up to 10 ஆண்டுகள். Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.

விரைவான மேற்கோளைப் பெறுங்கள்

உள்ளுக்குள் பதிலளிப்போம் 12 மணி, பின்னொட்டுடன் மின்னஞ்சலுக்கு கவனம் செலுத்துங்கள் “@fibconet.com”.

மேலும், நீங்கள் செல்ல முடியும் தொடர்பு பக்கம், இது ஒரு விரிவான படிவத்தை வழங்குகிறது.