MPO / MTP Data Center Cabling Manufacturer — Cassettes, Mga Patch Panel, Trunk Cables and Patch Cords
Gumagawa ang Fibconet 10 series of MPO / MTP fiber optic products for 40G, 100G, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.

Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 mga piraso across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 dB on assemblies built with Japanese-imported ferrules, and to typical 0.20–0.35 dB on standard builds with domestic Sanhuan ferrules.

Every finished cable is 100% inspected for insertion loss, ibalik ang pagkawala, end-face geometry, polarity, pagkakasunud-sunod ng hibla, haba at hitsura. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 MPO / MTP Products We Manufacture
Grupo 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.

modelo
Bilang ng Hibla
Interface
Karaniwang Paggamit

Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 sa 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion

12/24 Core High-Density Solution MPO Cassette Module
12 o 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base

8/12/24 MPO MTP Base sa 24 LC Ultra High Density 1U Modular
Hanggang sa 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows

Grupo 2 — Rack Patch Panels
Empty or pre-assembled 1U 19-inch chassis to hold cassette modules and to organise trunk cables at the top of the rack.

modelo
Rack Size
Loading
Karaniwang Paggamit

Data Center 19-inch Standard Rack MPO Patch Panel
1U
Empty chassis for cassettes
Standard MDA rack, modular build

Pre-assembled 1U 19-inch Rack LC MTP®/MPO Patch Panel
1U
Pre-terminated LC front, MPO back
Plug-and-play rack, no field assembly

Grupo 3 — Patch Cords and Trunk Cables

The physical link between MPO cassettes, mga patch panel, transceivers and MPO backbone runs.

modelo
Istruktura
Fiber Options
Karaniwang Paggamit

Factory Pre-termination MPO-MPO 3.0mm LSZH Patch Cord / Trunk Cable
MPO to MPO
OS2 / OM3 / OM4 / OM5
Backbone trunk, MDA to EDA

Fiber Optic MPO MTP Connector Patch Cord
MPO to MPO
OS2 / OM3 / OM4 / OM5
Rack-to-rack short jumper

FTTA MPO/MTP Fiber Optic Patch Cord Cable
MPO to MPO, outdoor jacket
OS2 / OM3 / OM4
Base station FTTA and outdoor short link

Grupo 4 — Loopback
Used to test transceiver ports, cassette continuity and rack integrity without pulling a full trunk link.

modelo
Interface
Hibla
Karaniwang Paggamit

OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
OM3 multimode
Multimode transceiver and cassette test

Grupo 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.

modelo
Angkop
Karaniwang Paggamit

Lahat ng Uri ng Fitting MPO/MTP Cleaner
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit

What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
MPO (Multi-fiber Push On) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Both mate with each other and both follow the same fiber count and polarity rules. Fibconet manufactures to the MPO standard and supplies MTP-compatible builds on request; the underlying optical spec is identical.
Polarity — Type A, Type b, Uri C

Polarity
Fiber Sequence
Karaniwang Paggamit

I -type a (Diretso)
1↔1, 2↔2 … 12↔12 straight-through
Point-to-point trunks with A-to-B duplex crossover in the patch cord

Type b (Reverse)
1↔12, 2↔11 … 12↔1 fully reversed
Direct connection to SFP+ / QSFP transceivers; most common for 40G/100G breakout

Uri C (Pair-swap)
Adjacent pairs swapped: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling

Polarity errors are the single most common cause of link-up failure on MPO systems. Confirm polarity at RFQ stage; we ship Type A / B / C per your bill of materials.
Gender — Male (with pins) vs Female (walang pin)

Lalaki: two guide pins protrude from the end-face. Used at fixed / patch-panel ends.
Female: walang pin, two guide-pin holes only. Used at the equipment / movable-jumper end.

Wrong gender at RFQ = the entire batch has to be re-terminated. Always specify Male-Female, Female-Female or Male-Male at the quotation stage.
Fiber Type — Match to Data Rate and Distance

Hibla
Haba ng daluyong
10G reach
40G / 100G reach
Karaniwang Paggamit

OM3 multimode
850 nm
550 m
100 m / 100 m (SR4)
Short rack-to-rack, cost-sensitive builds

OM4 multimode
850 nm
550 m
150 m / 150 m (SR4)
Standard data-center backbone

OM5 multimode
850 & 953 nm SWDM
550 m
≥ 150 m; supports 400G SR4.2
AI cluster and next-gen supercompute backbone

OS2 singlemode
1310 / 1550 nm
10 km +
10 km + (LR4 / DR4)
Inter-building, campus, DCI long-haul

Insertion Loss Grade — Standard vs Low-Loss

Grade
Max IL per mated pair
Pagbabalik Pagkawala
Karaniwang Paggamit

Pamantayan (SM APC)
≤ 0.70 dB
≥ 55 dB
Enterprise LAN, standard data-center runs

Low-Loss / Piling tao (SM APC)
≤ 0.35 dB (tipikal 0.25 dB)
≥ 55 dB
Cabinet-to-cabinet 100G high-density backbone

Ultra Low-Loss (Japanese ferrule)
0.15 dB per single fiber
≥ 55 dB
400G / 800G AI backbone; long link budgets

Pamantayan (MM PC)
≤ 0.50 dB
≥ 20 dB
OM3/OM4 short data-center runs

Low-Loss (MM PC)
≤ 0.35 dB (tipikal 0.20 dB)
≥ 20 dB
OM4/OM5 high-density backbone

Mga pagtutukoy sa teknikal

Tandaan: the values below are family-typical across the 10 serye, hindi isang solong-SKU na datasheet. Hilingin sa amin ang ulat ng pagsubok na partikular sa modelo sa yugto ng RFQ; ipinapadala namin ito sa ilalim ng numero ng bahagi ng modelo.

Parameter
Karaniwang Halaga
Magkomento

Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone

Uri ng hibla
OS2 (G.652.D, G.657.A1/A2), OM3, OM4, OM5
G.657.A2 for tight-radius rack routing

Polarity
I -type a / Type b / Uri C
Type B is default for 40G/100G breakout

Kasarian
Lalaki (with pins) / Female (walang pin)
Both ends selectable per port

End-face polish
APC (singlemode) / PC (multimode)
APC green, PC beige/aqua

Pagkawala ng pagpasok (nag-iisang hibla)
0.15 – 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules

Pagbabalik pagkawala
≥ 55 dB (SM APC), ≥ 45 dB (SM PC), ≥ 20 dB (MM PC)

Mating durability
≥ 500 mga cycle, IL drift ≤ 0.2 dB
Guide-pin positioning with elastic pre-load

Minimum na radius ng liko
MPO end ≥ 30 mm; LC breakout end ≥ 20 mm
Static 15 mm, pabago-bago 30 mm on G.657.A2 fiber

Temperatura ng pagpapatakbo
−20°C to +60°C
Optical performance stable across the range

Ingress / kahalumigmigan
IP50; 45°C / 95% RH; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed

Length range
0.2 sa 300 m custom; Ang lahat ng optical at mechanical index ay nakakatugon sa patch cord 0.5 sa 30 m
Bawat modelo

Trunk cable OD
3.0 mm tipikal (8/12/16/24F); ~5.0 mm (48F)
Higher fiber count = larger OD

Jacket
LSZH standard; OFNR / OFNP on request
Suitable for data hall, riser and plenum

Subukan ang wavelength
1310 / 1550 nm (SM), 850 / 1300 nm (MM)

Warranty
1 taon; design life up to 10 taon
Field replacement covered within warranty period

Kakayahan sa Paggawa at Kontrol sa Kalidad
Production Line and Monthly Capacity
Ang pangunahing operasyon ng Fibconet sa mga optical na passive na bahagi ay nagsimula noong 1994. Ang MPO / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 mga piraso. Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
Upstream Material Control
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. Kinokontrol namin ang upstream stack sa halip na ang assembly step lang:

Ferrules: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
Hibla: YOFC / Fiberhome / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
Aramid sinulid: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.

100% Pagsusuri ng Kalidad

Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
Polarity at pagkakasunud-sunod ng hibla: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.

Mga Sertipikasyon at Pagsunod
Gumagana ang Fibconet sa ilalim ng isang integrated ISO 9001 / ISO 14001 / ISO 45001 sistema ng pamamahala na sumasaklaw sa kalidad, kapaligiran at kalusugan sa trabaho & kaligtasan. Raw-material RoHS reports ship by default. Product-level compliance — CE, REACH, ang, ETL — is issued per model and per target market. Ang pagiging angkop ng sertipikasyon ay nag-iiba ayon sa mga kinakailangan ng produkto at proyekto. Ipadala sa amin ang iyong target na merkado at ang listahan ng modelo; we return the applicable certificate set with the quotation.
Packaging, OEM at Custom na Opsyon
Karaniwang Packaging

Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, dami, polarity and gender code.

OEM at Custom na Opsyon

Ang haba: anumang haba mula sa 0.2 m sa 300 m, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 cm) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3×8 / 4×6; 16F to 2×8; 48F to 6×8; hanggang 6 MPO connectors per single end on MPO-to-MPO breakouts.
Polarity: I -type a / B / C per port; internal crossover on Type B for direct SFP mating.
Ferrule grade: domestic Sanhuan or Japanese-imported per fiber-count / IL grade selection.
Kulay ng jacket: aqua (OM3), erika violet (OM4), lime green (OM5), dilaw (OS2), custom RAL.
Breakout root protection: wala (short runs), nylon boot (standard rack), braided sleeve (high-wear).
OEM label and printing: on connector body, PE bag and master carton.
Custom na packaging: PE bag and carton design per your artwork, MOQ 30,000 pcs for full custom packaging run.
Mga sample: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.

Mga Madalas Itanong
Q1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Q2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100G, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Q3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100G / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / SC / FC on the other?
Oo. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
Q5. Are both ends symmetric on MPO-to-MPO breakout cables?
Oo. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. Hanggang sa 6 MPO connectors per single end are supported.
Q6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100GSR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; we ship Type A / B / C per your bill of materials.
Q7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 dB. Ultra low-loss builds with Japanese ferrules reach 0.15 dB per single fiber. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
Q8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
Oo. Every cable and every fiber core is tested for insertion loss, ibalik ang pagkawala, end-face geometry, polarity, pagkakasunud-sunod ng hibla, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
Q9. Can I get samples before placing a bulk order?
Oo. Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
Q10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 mga piraso. Standard orders of several thousand pieces ship in 7–12 days from stock. Bulk orders above 20,000 pieces ship in 15–20 days. Custom packaging with full artwork runs from an MOQ of 30,000 mga pcs.
Q11. Can these MPO products be used outdoors?
The standard MPO line is optimised for data hall, MDA and rack environments (IP50, −20°C to +60°C, LSZH). For outdoor and FTTA applications, use the FTTA MPO/MTP Fiber Optic Patch Cord with an outdoor jacket, or ask for a custom outdoor build. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. What is the warranty?
Standard warranty is 1 taon; design service life is up to 10 taon. Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.