E hamani te FIBCONET i te mau uira Te mau mana'o tauturu no te haapiiraa e Te mau nota i roto e pae utuafare tao'a — simplex & duplex i roto i te fare, toparaa pape, mauhaa tama'i, MPO teitei, e te mau pigtails ODF — e te mau hu'ahu'a amui hau atu i te 13 Mirioni aho i te ava'e. Te mau taura atoa 100% Ua tamatahia no te ereraa i te faaôraa, Te mau mana'o tauturu no te haapiiraa, te puai o te tensile e te huru o te mata hou a tapo'ihia ai.
E faaî ta tatou mau aho i te mau titauraa hi'opoaraa e au i te TE MAU NOTA 61300 (Piha haapiiraa U) e GR-326-CORE (Buka arata'i haapiiraa). No roto mai te mau hu'ahu'a optical i na tapao rahi e maha o te fenua Taina - YOFC, ZTT, Hengtong e te fare. E faaohipa te mau ferrules ceramic i te mau anairaa CCTC (E roaa te mau hu'ahu'a Sumitomo ia anihia), e no te faaau i te mau haamau'araa e te hoho'a o ta outou opuaraa, e haamata te mau faito tuati mai te faito o te faanahoraa e tae atu i te faito o te afata teata.
Beyond standard telecom cords, to tatou MPO / MTP high-density line supports 40G, 100G, 400G and 800G parallel optical transmission — the current mainstream for AI-driven data-centre buildouts and hyperscale MDA cabling. See the MPO section below.

| Te mau tumu parau | Faaohiparaa matauhia | Te mau haamaramaramaraa faufaa | Te mau tu'atiraa |
|---|---|---|---|
| Indoor Simplex & Duplex Patch Cord | Data-centre patching, telecom room, cross-connect, in-cabinet routing | Insertion loss avg ≤ 0.3 DB; tensile 45 N; 2.0 / 3.0 mm ahu; LSZH available | SC, LC, FC, TE MAU PARAU APÎ O TE EKALESIA, MU, MTRJ, E2000 — PC / UPC / APC |
| I rapaeau & Waterproof Drop Patch Cord | FTTH toparaa, outdoor terminal box, CPRI fronthaul, base-station link | IP-rated seal; UV-resistant jacket; pre-connectorized options for 1–4 core drop | Mini SC, SC/APC, LC/APC waterproof |
| Te mauhaa tama'i & Anti-Rat Patch Cord | Data-centre under-floor, in-conduit runs, underground burial, te mau vahi fifi | 201 stainless-steel spiral armor; tensile 140 N (2× standard); salt-spray 24 h; operating −40 to +85 °C | SC, LC, FC — UPC / APC |
| MPO / MTP High-Density Cord ⭐ | Data-centre MDA, AI compute cluster fabric, 40G/100G/400G/800G parallel optics, high-density cabinet | Tae atu i te 72 fibers per MPO; single-mode IL down to 0.15 DB; multimode low-loss ≤ 0.35 DB; ≥ 500 te mau huriraa taa ê | MPO / MTP male & Vahine; hybrid MPO–LC / MPO–SC / MPO–FC breakout |
| Indoor Pigtail | ODF splicing, distribution box terminals, fusion-splice on-site | 0.9 mm buffered pigtail; faatureraa 1.5 m length; custom lengths supported | SC, LC, FC — UPC / APC |
Every series above is 100% factory-tested (end-face, Te mau nota, Te mau mana'o tauturu no te haapiiraa, tensile). Electronic test reports in FLUKE or EXFO format are available with each order.

| Patch Cord | Pigtail | |
|---|---|---|
| Connectorization | Connectors on both ends | Connector on one end only; other end bare fiber for fusion splicing |
| Primary use | Equipment-to-equipment or equipment-to-panel | ODF / distribution-box termination, fusion-spliced to the incoming cable |
| Roaraa | Te mau nota 0.5 – 30 m; custom up to 300 m | Te mau nota 1.0 – 1.5 m; custom on request |
| Te mau mana'o tauturu no te | Tāuta-e-ha'uti | Requires fusion splicer on-site |
| Best for | Data centre patching, MDA, cross-connect, PON drop | Central office, ODF panel splicing, distribution frames |
We manufacture patch cords with all mainstream connectors: FC, TE MAU PARAU APÎ O TE EKALESIA, SC, LC, MU, MPO / MTP, E2000, MTRJ, SMA. End-face contact is available in three types:
For module ports, LC, SC and MPO / MTP dominate. LC is the default for high-density optical modules; SC is standard for FTTH; MPO handles high-count parallel links.
| Jacket type | Best for | Te mau nota |
|---|---|---|
| Standard PVC | General indoor use | Lowest cost |
| Flame-Retardant PVC | Data centres, plenums with local fire code | Meets basic flame ratings |
| LSZH (Te au auahi Zero Halogen) | Data centres, telecom rooms, nga tunnels, subways | No halogens, low smoke, no corrosive gas — European & DC standard |
| LSZH Flame-Retardant | Strict fire-code data centres and public buildings | Combines LSZH with elevated flame retardance |
| 201 Stainless-Steel Armored | I rapaeau, hunahia, rodent-prone, harsh environment | 140 N tensile; 24 h salt-spray |
Te mau mana'o tauturu no te haapiiraa (Te mau nota), dual-core (Te mau nota), and multi-core cables in 4, 6, 8, 12, 24, 48 and 72-core Te mau nota. Custom core counts and lengths supported on request. Standard patch cord lengths run 0.5–30 m; custom lengths up to 300 m for special projects. Standard pigtail length is 1.0 – 1.5 m.
MPO / MTP is the connector platform driving the next decade of data-centre and AI cabling. A single MPO connector carries 8, 12, 16, 24, tae atu i te 72 Te mau nota, replacing dozens of individual patch cords with one plug. Our dedicated MPO production runs 150,000 cords per month e te 100% ferrule interferometer inspection and per-core polarity verification.
| Link Speed | Fiber Count Required | Te huru o te Fiber | Tae atu |
|---|---|---|---|
| 40G SR4 | 8 Te mau nota (4Tx + 4Rx) | OM3 / OM4 | Tae atu i te 550 m (OM4) |
| 100G SR4 / SR10 | 8 e aore râ, 20 Te mau nota | OM3 / OM4 / OM5 | Tae atu i te 550 m |
| 400G SR8 / DR4 | 16 Te mau nota / 8 Te mau nota | OM4 / OM5 / Taata a'o ia au i te ana'iraa tamarii | Tae atu i te 100 m (SR8) / 500 m (DR4) |
| 800G SR8 | 16 Te mau nota | OM4 / OM5 | Tae atu i te 100 m — today’s AI cluster mainstream |
When you place an order, please confirm polarity type, gender configuration, connector-color scheme, and core-count breakout — our sales team will validate against your target optical modules before production begins.
| Parameter | Iteraa rau o te peu maitai |
|---|---|
| Test standard | TE MAU NOTA 61300 (Piha haapiiraa U); GR-326-CORE (Buka arata'i haapiiraa) |
| Te ereraa i te mau mea atoa (tino'ā) | Standard ≤ 0.3 DB; low-loss grade ≤ 0.15 DB (MPO single-mode) |
| Te ho'iraa i te fare | UPC ≥ 50 DB; TE MAU ≥ 55 DB |
| Te anuvera e tere ra | −20 to +60 °C (faatureraa); −40 to +85 °C (mauhaa tama'i & branch series) |
| Te anuvera o te haaputuraa | −40 to +85 °C |
| Te maoro o te faaipoiporaa | SC / LC / FC ≥ 1,000 Te mau mana'o; MPO ≥ 500 Te mau mana'o |
| Te puai no te ti'araa p | Faatureraa 45 N; te tahi mau 40 N (tau roa); mauhaa tama'i 140 N |
| Radio | Standard cord 10 mm; MPO branch 15 mm static / 30 mm dynamic; armored 35–40 mm |
| Te mau mana'o tauturu no te haapiiraa | 1-matahiti fare hamaniraa tauihaa; design service life 10 te mau matahiti |

| Te mau tumu parau | Monthly Output |
|---|---|
| Simplex patch cord | 10,000,000 cords |
| Duplex patch cord (top-3 producer nationally) | 3,000,000 cords |
| MPO / MTP series | 150,000 cords |
| Breakout patch cord | 90,000 cords |
Optical fiber sourced from China’s four leading brands — YOFC, ZTT, Hengtong e te fare — the same feedstock trusted by tier-1 operators worldwide. Ceramic ferrules are Sanhuan series by default, e te Sumitomo ferrules available on request for the tightest concentricity requirements. Jacket compounds come from Shanghai Kaibo, a stable supplier to the same four fiber manufacturers.
Insertion-loss variation between production batches is held within ±0.08 dB. Colour consistency for OEM orders is managed by keeping a first-piece reference sample from every batch for direct comparison on subsequent orders.
Certification applicability varies by product line and destination market. Please confirm target market and required standards when requesting a quotation.
Standard simplex and duplex patch cords have no MOQ — sample and trial orders are welcome. MPO cords typically start at 100 fa'ahouhia. Armored cords have a 1,000-piece MOQ due to armor tooling setup; delivery within 10 Te mau nota. OEM-printed packaging requires 5,000 pieces minimum.
Regular configurations of simplex, duplex and standard MPO ship from stock within days — we keep 2,000–3,000 pieces of common SKUs like SC/UPC duplex 2.0 mm LSZH in-stock. MPO custom orders: 7–12 days for a few thousand pieces; 15–20 days for orders above 20,000 Te mau nota. Branch patch cords: samples ready in 3 Te mau nota.
E. Every cord ships with 100% factory testing (IL, RL, end-face, tensile). Electronic test reports in FLUKE or EXFO format are available after order placement. 3D end-face inspection is standard on all MPO production and available on request for other cord types.
Standard-grade MPO: insertion loss ≤ 0.7 DB (Te mau nota 850 / 1310 m). Low-loss grade: ≤ 0.35 dB average. Single-mode MPO with high-precision imported ferrules can reach IL as low as 0.15 DB for testing and telecom-grade applications. Standard grade covers enterprise networks and office cabling; low-loss grade is designed for high-density cabinet cabling and 100G+ mainstream links.
E. Standard MPO breakout defaults: 12-core → 6 duplex LC; 24-core → 12 duplex LC. Custom splits including 2×12, 3×8, 4×6 and other ratios are fully supported. MPO–MPO breakout allows up to 6 MPO connectors on a single end, with both ends symmetric. Trunk length range: 0.2 m 300 m; branch length differences within a single cable should stay within 30 cm to avoid fiber-stress attenuation drift.
Our MPO cords stably support 40G, 100G, 400G e 800G parallel optical transmission. This makes them suitable for current AI data-centre cluster fabric, hyperscale MDA cabling, and next-generation coherent transport buildouts. OM4 / OM5 multimode is the current mainstream for 400G / 800G SR8 links; single-mode covers longer reach and DR4 architectures.
E. Our patch cords meet the applicable UL, ETL and TUV test standards. Formal third-party certification can be arranged per project on request — test cost is quoted separately depending on the scope required.
Optical fiber from YOFC, ZTT, Hengtong e te fare. Ceramic ferrules are Sanhuan by default; Sumitomo ferrules available on request. Connector grades range from network-level (mainstream cost-performance) to telecom-level (highest concentricity, lowest IL) — specify per project.
Our armored patch cords use a 201 stainless-steel spiral armor layer. Tensile strength reaches 140 N (e te 70 N for standard cords) and the armor passes a 24-hour salt-spray test, making them suitable for marine shipping and coastal deployments. Best for static routing with occasional bending — not recommended for high-frequency repeated flexing. For buried installations, an additional protective conduit is recommended to prevent long-term corrosion.
E. We produce to your artwork — custom colour boxes, outer carton logo, private-label PE bags, spec-sheet inserts and branded manuals. Neutral packaging is available with no minimum quantity. Printed packaging with custom logo requires 5,000 pieces minimum to justify plate setup.
E pahono tatou i roto 12 Te mau hora, a haapa'o maitai i te rata uira e te suffix " @fibconet.com ".
A hi'o atoa, e nehenehe ta oe e haere i te Api no te farereiraa, o te horo'a mai i te hoê parau haamaramaramaraa hau atu.