ترجمہ میں ترمیم کریں۔
تلاش کریں۔

فائبر آپٹک کیبل

Fiber Optic Cable Manufacturer — GYTS, GYTA, ADSS, ASU, ڈراپ, Air-Blown Micro & Submarine Cable

FIBCONET has manufactured fiber optic cable in China for 12 سال, running dedicated automated lines for stranded loose-tube, central-tube, خود کی حمایت, air-blown micro and submarine cable series.

Combined output on our mainstream armored lines (جی وائی ٹی ایس / GYTA) reaches tens of millions of fiber-kilometers per year, with stock inventory maintained across 4–288-core standard configurations.

فائبر آپٹک کیبل ڈھانچہ

Every drum ships after 100% factory testing — attenuation, tensile, water penetration and end-of-drum OTDR trace — against آئی ای سی 60794 series and other applicable standards. Our submarine cable also complies with جی بی/ٹی 18480, ITU-T G.976 and GJB 4489 military-grade specifications.

Below are the twelve cable series currently shipping to telecom operators, engineering contractors, power utilities and FTTH integrators across Southeast Asia, the Middle East, Latin America and Europe. Each product page carries fiber count options, connector-ready pre-termination, and full mechanical / environmental specifications.

Fiber Optic Cable Series We Manufacture

کیبل کی قسم ماڈل تعیناتی Max Fiber Count Key Highlight
Stranded Loose Tube, Steel-Tape Armored جی وائی ٹی ایس نالی, فضائی 288 ریشے Long-term tensile 600 ن; کچلنا 300 N/100 mm; 20-year jacket life
Stranded Loose Tube, Aluminum-Tape Armored GYTA نالی, فضائی (PE conduit for direct burial) 288 ریشے Anti-rodent, moisture-blocking, EMI-shielding; UV-additive option extends life +5 سال
Central Loose Tube, Non-Metallic GYXTY / GYFXY (FRP-reinforced) ہوائی, ڈکٹ, lightning-prone regions 24 ریشے ہلکا پھلکا, all-dielectric; jacket down to 1.1 ملی میٹر; 10,000 کلومیٹر / month output
تمام ڈائی الیکٹرک سیلف سپورٹنگ (ADSS), Single-Jacket ADSS Single-Jacket ہوائی, power-line corridors, spans up to 300 m 144 ریشے Aramid strength member; PE jacket 1.8 mm ± 0.1 ملی میٹر; 25–40% lower cost than double-jacket
ADSS, Double-Jacket ADSS Double-Jacket Aerial in coastal salt-fog, آئسنگ, long-span installations 288 (تک 576 custom) 10–15 years extended service life vs single-jacket; 720 h نمک کے سپرے کا تجربہ کیا گیا۔; UV per GB/T 18899-2023
Aerial Self-Supporting (ASU) ASU / GYFXY-lightweight Short-span aerial & duct dual use, تک 120 ایم اسپین 24 ریشے 3,000 h UV without cracking; 15-year warranty with 1:1 defect replacement; lower cost than ADSS
Figure-8 Central-Tube GYXTC8S Aerial with integral messenger, تک 100 ایم اسپین 96 ریشے 7×1.2 galvanized steel strand messenger, 5 kN tensile; 30-year UV per IEC 60794-1
Air-Blown Micro Cable gcyfy / GCYFXY Microduct systems 144 ریشے (stranded); 24 ریشے (central-tube) Outer diameter from 1.8 ملی میٹر; grooved jacket for extended blowing distance; HDPE or LSZH
FTTH Drop Cable, Bow-Type Self-Supporting ГХХЧЧ FTTH outdoor drop with steel or FRP messenger 1–4 fibers G.657.A2 default; steel-wire or non-metallic (ایف آر پی) messenger; LSZH / PE / پیویسی جیکٹ
FTTH Drop Cable, Indoor Bow-Type جی جے ایکس ایچ FTTH indoor drop, اٹھنے والا 1–4 fibers LSZH jacket standard; G.657.A2 bend-insensitive fiber
انڈور ڈسٹری بیوشن کیبل GJFJV / tight-buffer Building risers, indoor cabling, patch cord raw stock 2–24 fibers 5 production lines × 180 km/day; long-term tensile 200 ن (2.0 ملی میٹر); operating −20 to +70 °C
Submarine Cable GYTA33 & deep-water armored ساحلی, island interconnect, offshore platforms, deep-water up to 8,000 m 288 ریشے 100 Gb/s unrepeated span up to 500 کلومیٹر; long-term tensile 4 kn, short-term 10 kn; 25-year design life; meets GB/T 18480, آئی ای سی 60794, ITU-T G.976 and GJB 4489

او پی جی ڈبلیو (آپٹیکل گراؤنڈ تار) and photoelectric composite cable are also part of our line for power-utility deployments — see the OPGW product page for structural options and short-circuit current ratings.

fiber optic cable series

How to Choose the Right Fiber Optic Cable

Three questions determine the right cable for a project: where it’s installed, how many fibers it carries, اور what mechanical / environmental loads it faces.

1. Match the Cable to the Deployment Environment

Deployment Environment تجویز کردہ سیریز کیوں
نالی / نالی (standard telecom trunk) GYTS or GYTA Armored, high tensile, 20-سال سروس کی زندگی
ہوائی, lightning-prone region GYFTY / GYXTY (non-metallic) or ADSS All-dielectric prevents lightning damage
Aerial along power lines (spans > 100 m) ADSS Single-Jacket (temperate) or Double-Jacket (coastal / آئسنگ) Self-supporting up to 300 m; aramid-yarn strength
Direct burial GYTA53 (double-jacket + steel-tape armor) or GYTA + PE conduit Rodent, crush and moisture protection
Microduct (existing or new) Air-Blown Micro Cable (gcyfy / GCYFXY) 1.8 mm minimum diameter, groove jacket for blow distance
Short-span aerial + duct dual-use ASU Cheaper than ADSS, higher tensile than standard drop cable
Aerial with integral messenger, mid-span Figure-8 GYXTC8S Built-in steel messenger, 5 kN tensile, 100 ایم اسپین
FTTH outdoor drop GJYXCH bow-type self-supporting Steel or FRP messenger; G.657.A2 bend-insensitive fiber
FTTH indoor drop / اٹھنے والا GJXH indoor bow-type LSZH jacket for building fire code
ساحلی, island interconnect, offshore Submarine cable (GYTA33 series) HDPE jacket, galvanized or Zn-Al armored steel wires
Power utility ground wire او پی جی ڈبلیو Composite power ground + آپٹیکل کیبل

2. Calculate the Fiber Count You Need

A working formula: total equipment ports × 2, plus a 10–20% spare buffer. For serial-multiplexed devices the count can be lower. Standard fiber counts we stock: 2, 4, 6, 8, 12, 24, 48, 96, 144, 288. Non-standard counts including 576-core (ADSS double-jacket) درخواست پر دستیاب ہیں۔.

3. Match Jacket and Armor to the Load Profile

  • Standard PE — general outdoor, 20-سال سروس کی زندگی
  • UV-additive PE — extends outdoor life by ~5 years for high-solar regions
  • پر (اینٹی ٹریکنگ) PE — for ADSS installed near high-voltage lines to resist electrical corrosion
  • LSZH — low smoke zero halogen for tunnels, subways, data centres and indoor riser
  • ایچ ڈی پی ای — submarine, high-crush and pressure environments
  • Steel-tape armor (جی وائی ٹی ایس) — rodent protection, نمی, EMI shielding
  • Aluminum-tape armor (GYTA) — equivalent protection, lower weight, better in some corrosive environments
  • 316L stainless steel armor — coastal / marine upgrade for figure-8 messenger; Zn-Al plated for corrosion

GYTS vs GYTA vs ADSS — Quick Comparison for Telecom Trunk Cabling

جی وائی ٹی ایس GYTA ADSS
Armor Corrugated steel tape Corrugated aluminum tape None (all-dielectric)
Strength member Steel wire (FRP for lightning zones) Steel wire آرام دہ سوت
Aerial span limit ~80 m ~80 m تک 300 m
Direct burial PE conduit recommended PE conduit mandatory قابل اطلاق نہیں۔
کے لیے بہترین Standard duct / فضائی, high-rodent risk Same as GYTS, lower weight Long-span aerial along power poles

Technical Specifications Across Trunk Cable Series

پیرامیٹر قدر
Fiber grade (پہلے سے طے شدہ) G.652.D (کے بارے میں 90% of shipments); g.657.a1, g.657.a2, G.654.E and OM3 / OM4 / OM5 on request
توجہ 1310 nm ≤ 0.35 dB/km
توجہ 1550 nm ≤ 0.21 dB/km
Fiber count range 2 - 288 cores standard; تک 576 cores custom (ADSS double-jacket)
کم سے کم موڑ رداس ≥ 10× cable diameter (جامد); ≥ 20× diameter (متحرک)
Long-term tensile strength GYTS/GYTA 600 ن; Figure-8 5 kn; Submarine 4 kN long-term / 10 kN installation
کرش مزاحمت ≥ 300 N/100 mm (armored series)
آپریٹنگ درجہ حرارت -40 سے +70 °C (بیرونی); −20 to +70 °C (indoor LSZH / پیویسی)
ڈیزائن سروس کی زندگی Outdoor armored 20 سال; ADSS double-jacket 25–30 years; سب میرین 25 سال
ٹیسٹنگ 100% drum-by-drum attenuation test; OTDR trace archived per drum

Submarine Cable — Our Deep-Water Line ⭐

Our submarine cable line targets short-haul unrepeated systems — island interconnect, offshore platform tie-in, coastal loops — where a single-span 100 Gb/s link up to 500 کلومیٹر eliminates the cost of subsea repeaters, power feed and maintenance.

  • Depth rating: standard shallow-water build for up to 100 m (most common); deep-water build rated up to 8,000 m
  • فائبر کا شمار: تک 288 ریشے
  • Armor: shallow-water uses hot-dip galvanized low-carbon round steel wire; deep-water uses high-carbon high-tensile round steel wire with zinc-aluminum alloy coating
  • جیکٹ: HDPE for seawater corrosion, water blocking and pressure resistance
  • Tensile: long-term 4 kn, short-term installation 10 kn
  • معیارات کی تعمیل: جی بی/ٹی 18480, آئی ای سی 60794, ITU-T G.976, GJB 4489
  • ڈیزائن سروس کی زندگی: اس سے کم نہیں 25 سال
  • تنصیب کے طریقے: trench burial (flat silt/sand seabed), surface laying (calm water), casing protection (rocky/reef zones), underwater suspension (bay spans)

Manufacturing Capability

Automated Production Lines with Inline Inspection

Our GYTS / GYTA lines run imported cabling machines, high-speed secondary coating equipment, and dual-layer co-extrusion jacket lines. Inline laser concentricity gauges and real-time OTDR scanners monitor every step. A three-stage water-blocking process controls excess fiber length, tape thermal bonding and jacket extrusion parameters through digital process control.

Annual Output & Stock Position

  • جی وائی ٹی ایس / GYTA: tens of millions of fiber-kilometers per year across all core counts, with 4–288-core standard configurations kept in stock
  • GYXTY: ~10,000 km per month
  • Indoor distribution cable: 5 production lines × 180 km per line per day
  • ADSS Single-Jacket: 12–48-core kept in stock; MOQ 1 کلومیٹر
  • ASU: 2–24-core standard in stock; same-day shipping for regular configurations
  • Figure-8: 2–48-core in stock across 4 dedicated extrusion lines

100% Drum-by-Drum Testing

  • Attenuation test on every drum before shipment — not sampling
  • Length tolerance strictly controlled within +1 کو +2 metres per drum
  • Per-drum OTDR trace archived and provided to buyer on request
  • Tensile, water-penetration and aging test reports available under IEC 60794 طریقہ کار

Container Loading & پیکیجنگ

Standard drum length is 1–3 km per wooden reel for most trunk series; custom drum lengths supported on request. Approximate cable-length loading per container for figure-8 and similar profiles:

  • 20 GP container: 800 - 1,200 km of cable
  • 40 ہیڈکوارٹر container: 1,900 - 2,800 km of cable

Actual loading depends on cable diameter, drum size and stacking configuration — our sales team will calculate exact quantities against your PO.

سرٹیفیکیشن اور تعمیل

  • آئی ایس او 9001 کوالٹی مینجمنٹ سسٹم, فیکٹری وسیع
  • آئی ای سی 60794 series — optical cable performance, environmental and mechanical test methods
  • یہ — European conformity for applicable product lines
  • دی / Etl — available for North American market entry
  • سی پی آر — European Construction Products Regulation, for cables installed in permanent buildings
  • RoHS — hazardous substance compliance; certificates renewed annually
  • Submarine cable additionally complies with جی بی/ٹی 18480, ITU-T G.976 and GJB 4489

سرٹیفیکیشن کا اطلاق پروڈکٹ لائن اور منزل مارکیٹ کے لحاظ سے مختلف ہوتا ہے۔. Please confirm the target country, deployment environment and required standards when requesting a quotation.

Frequently Asked Questions About Fiber Optic Cable Sourcing

Q1. What is your minimum order quantity?

Standard trunk cable MOQ is 1 کلومیٹر. Indoor distribution cable also 1 km MOQ; custom-colour indoor cable requires 5 کلومیٹر. Submarine cable typically starts at 100 km due to the specialized production line setup. Bow-type drop cable ships from standard stock.

Q2. What is the standard lead time?

Regular 2–48-core GYTS / GYTA / GYXTY / ASU configurations ship from stock within days. Custom fiber counts, lengths or non-standard jackets: typically 15–25 working days depending on drum count. Submarine cable and 288-core+ builds require project-specific scheduling.

Q3. Which fiber grade do you use as default?

کے بارے میں 90% of our finished cable ships with G.652.D single-mode fiber. G.657.A1 and G.657.A2 bend-insensitive grades are our default for drop cable and tight-space installations. G.654.E for long-haul 400G+ backbone and OM3 / OM4 / OM5 multimode for data-centre indoor cable are available on request.

Q4. Can you provide OTDR traces and test reports per drum?

ہاں. Every drum ships after 100% attenuation testing, with the OTDR trace archived. Written test reports covering tensile, water penetration and thermal aging are available under IEC 60794 methodology on request — useful for project acceptance and customs clearance.

Q5. Can you customize drum length, colour and marking?

ہاں. Standard drums are 1–3 km; longer runs supported on request (جیسے. ADSS in 500 m, 1200 m or segmented lengths). Jacket colour customization has a 5 km MOQ. Sequential metre marking, batch code and buyer logo can be printed to your specification.

faq

Q6. What certifications can you supply for European and North American markets?

Our cable ships with ISO 9001, یہ, RoHS and IEC 60794 compliance as standard. دی / ETL certifications are supported for North American entry; CPR is available for cable installed in permanent European buildings. Third-party test reports and country-specific certification can be arranged per project.

Q7. How do I choose between GYTS, GYTA, GYFTY, ADSS and ASU?

Short answer: استعمال کریں GYTS or GYTA for standard duct / aerial trunk cabling; GYFTY when a non-metallic (unarmored) cable is required; ADSS single-jacket for aerial spans up to 300 m in temperate conditions, double-jacket for coastal salt-fog or ice-loaded spans; ASU for short-span aerial + duct dual-use where you want the strength of ADSS without the cost. Detailed matrix above.

Q8. Do you supply cables suitable for direct burial?

For direct burial we recommend GYTA53 (double-jacket with steel-tape armor) or GYTA with an additional PE protective conduit. Standard single-jacket ASU and ADSS are not designed for direct burial — the buried environment will corrode the jacket over time.

Q9. What is the warranty and service life?

Standard factory warranty is 1 سال. ڈیزائن سروس کی زندگی: 20 years for standard outdoor armored cable; 25–30 years for ADSS double-jacket and submarine cable; 15 years for ASU with 1:1 defect replacement if the failure is traced to manufacturing.

Q10. How much cable fits in a shipping container?

For figure-8 and similar profiles: a 20 GP container carries approximately 800–1,200 km of cable; a 40 HQ carries 1,900–2,800 km. Exact loading varies with cable OD, drum size and stacking. Provide us the drum spec and we’ll calculate loading before the PO is placed.

ایک فوری اقتباس حاصل کریں۔

ہم اندر ہی اندر جواب دیں گے۔ 12 گھنٹے, براہ کرم لاحقہ کے ساتھ ای میل پر توجہ دیں۔ "@fibconet.com".

بھی, آپ جا سکتے ہیں رابطہ صفحہ, جو مزید تفصیلی شکل فراہم کرتا ہے۔.