Ṣatunkọ Itumọ
Wa

Okun Optic Cable

Fiber Optic Cable Manufacturer — GYTS, GYTA, ADSS, ASU, Ju silẹ, Air-Blown Micro & Submarine Cable

FIBCONET has manufactured fiber optic cable in China for 12 ọdun, running dedicated automated lines for stranded loose-tube, central-tube, self-supporting, air-blown micro and submarine cable series.

Combined output on our mainstream armored lines (GYTS / GYTA) reaches tens of millions of fiber-kilometers per year, with stock inventory maintained across 4–288-core standard configurations.

okun opitiki USB be

Every drum ships after 100% factory testing — attenuation, fifẹ, water penetration and end-of-drum OTDR trace — against IEC 60794 jara and other applicable standards. Our submarine cable also complies with GB/T 18480, ITU-T G.976 and GJB 4489 military-grade specifications.

Below are the twelve cable series currently shipping to telecom operators, engineering contractors, power utilities and FTTH integrators across Southeast Asia, Aringbungbun oorun, Latin America and Europe. Each product page carries fiber count options, connector-ready pre-termination, and full mechanical / environmental specifications.

Fiber Optic Cable Series We Manufacture

USB Iru Awoṣe Ifiranṣẹ Max Fiber Count Key Highlight
Stranded Loose Tube, Steel-Tape Armored GYTS Opopona, eriali 288 awọn okun Long-term tensile 600 N; fifun pa 300 N/100 mm; 20-year jacket life
Stranded Loose Tube, Aluminum-Tape Armored GYTA Opopona, eriali (PE conduit for direct burial) 288 awọn okun Anti-rodent, moisture-blocking, EMI-shielding; UV-additive option extends life +5 ọdun
Central Loose Tube, Non-Metallic GYXTY / GYFXY (FRP-reinforced) Eriali, ri, lightning-prone regions 24 awọn okun Ìwúwo Fúyẹ́, all-dielectric; jacket down to 1.1 mm; 10,000 km / month output
Gbogbo-Dielectric ara-atilẹyin (ADSS), Single-Jacket ADSS Single-Jacket Eriali, power-line corridors, pan soke si 300 m 144 awọn okun Aramid strength member; PE jacket 1.8 mm ± 0.1 mm; 25–40% lower cost than double-jacket
ADSS, Double-Jacket ADSS Double-Jacket Aerial in coastal salt-fog, iyẹfun, long-span installations 288 (titi di 576 custom) 10–15 years extended service life vs single-jacket; 720 h iyọ-sokiri idanwo; UV per GB/T 18899-2023
Aerial Self-Supporting (ASU) ASU / GYFXY-lightweight Short-span aerial & duct dual use, titi di 120 m igba 24 awọn okun 3,000 h UV without cracking; 15-year warranty with 1:1 defect replacement; lower cost than ADSS
Figure-8 Central-Tube GYXTC8S Aerial with integral messenger, titi di 100 m igba 96 awọn okun 7×1.2 galvanized steel strand messenger, 5 kN tensile; 30-year UV per IEC 60794-1
Air-Blown Micro Cable GCYFY / GCYFXY Microduct systems 144 awọn okun (stranded); 24 awọn okun (central-tube) Outer diameter from 1.8 mm; grooved jacket for extended blowing distance; HDPE or LSZH
FTTH Drop Cable, Bow-Type Self-Supporting ГХХЧЧ FTTH outdoor drop with steel or FRP messenger 1–4 fibers G.657.A2 default; steel-wire or non-metallic (FRP) messenger; LSZH / LORI / PVC jaketi
FTTH Drop Cable, Indoor Bow-Type GJXH FTTH indoor drop, dide 1–4 fibers LSZH jacket standard; G.657.A2 bend-insensitive fiber
Abe ile Distribution USB GJFJV / tight-buffer Building risers, inu ile cabling, patch cord raw stock 2–24 fibers 5 production lines × 180 km/day; long-term tensile 200 N (2.0 mm); operating −20 to +70 °C
Submarine Cable ⭐ GYTA33 & deep-water armored Etikun, island interconnect, offshore platforms, deep-water up to 8,000 m 288 awọn okun 100 Gb/s unrepeated span up to 500 km; long-term tensile 4 kN, short-term 10 kN; 25-igbesi aye apẹrẹ ọdun; pade GB/T 18480, IEC 60794, ITU-T G.976 and GJB 4489

OPGW (Okun waya ilẹ) ati okun alapọpọ fọtoelectric tun jẹ apakan ti laini wa fun awọn imuṣiṣẹ agbara-agbara - wo oju-iwe ọja OPGW fun awọn aṣayan igbekalẹ ati awọn idiyele lọwọlọwọ-kukuru.

okun opitiki USB jara

Bii o ṣe le Yan Okun Fiber Optic Ọtun

Awọn ibeere mẹta pinnu okun ti o tọ fun iṣẹ akanṣe kan: ibi ti o ti fi sori ẹrọ, melo ni awọn okun ti o gbe, ati ohun ti darí / awọn ẹru ayika ti o dojukọ.

1. Baramu USB si Ayika imuṣiṣẹ

Ayika imuṣiṣẹ Niyanju Series Kí nìdí
Opopona / conduit (boṣewa Telikomu ẹhin mọto) GYTS tabi GYTA Armored, giga fifẹ, 20-odun iṣẹ aye
Eriali, ẹkùn-ìmọ-ina LTD / GYXTY (ti kii-ti fadaka) tabi ADSS Gbogbo-dielectric idilọwọ awọn bibajẹ monomono
Eriali pẹlú agbara ila (igba > 100 m) ADSS Single-Jacket (iwọn otutu) tabi Double-Jakẹti (eti okun / iyẹfun) Atilẹyin ti ara ẹni titi di 300 m; aramid-owu agbara
Isinku taara GYTA53 (ni ilopo-jaketi + irin-teepu ihamọra) tabi GYTA + PE okun Rodent, fifun pa ati ọrinrin Idaabobo
Microduct (tẹlẹ tabi titun) Air-Blown Micro Cable (GCYFY / GCYFXY) 1.8 mm minimum diameter, groove jacket for blow distance
Short-span aerial + duct dual-use ASU Cheaper than ADSS, higher tensile than standard drop cable
Aerial with integral messenger, mid-span Figure-8 GYXTC8S Built-in steel messenger, 5 kN tensile, 100 m igba
FTTH outdoor drop GJYXCH bow-type self-supporting Steel or FRP messenger; G.657.A2 bend-insensitive fiber
FTTH indoor drop / dide GJXH indoor bow-type LSZH jacket for building fire code
Etikun, island interconnect, ti ilu okeere Submarine cable (GYTA33 series) HDPE jacket, galvanized or Zn-Al armored steel wires
Power utility ground wire OPGW Composite power ground + okun opitika

2. Calculate the Fiber Count You Need

A working formula: total equipment ports × 2, plus a 10–20% spare buffer. For serial-multiplexed devices the count can be lower. Standard fiber counts we stock: 2, 4, 6, 8, 12, 24, 48, 96, 144, 288. Non-standard counts including 576-core (ADSS ni ilopo-jaketi) wa lori ìbéèrè.

3. Match Jacket and Armor to the Load Profile

  • Standard PE — general outdoor, 20-odun iṣẹ aye
  • UV-additive PE — extends outdoor life by ~5 years for high-solar regions
  • AT (egboogi-titele) LORI — for ADSS installed near high-voltage lines to resist electrical corrosion
  • LSZH — low smoke zero halogen for tunnels, alaja, data centres and indoor riser
  • HDPE — submarine, high-crush and pressure environments
  • Steel-tape armor (GYTS) — rodent protection, ọrinrin, EMI shielding
  • Aluminum-tape armor (GYTA) — equivalent protection, lower weight, better in some corrosive environments
  • 316L stainless steel armor — coastal / marine upgrade for figure-8 messenger; Zn-Al plated for corrosion

GYTS vs GYTA vs ADSS — Quick Comparison for Telecom Trunk Cabling

GYTS GYTA ADSS
Ihamọra Corrugated steel tape Corrugated aluminum tape None (all-dielectric)
Ẹgbẹ agbara Irin okun waya (FRP for lightning zones) Irin okun waya Aramid owu
Aerial span limit ~80 m ~80 m Titi di 300 m
Isinku taara PE conduit recommended PE conduit mandatory Ko ṣiṣẹ fun
Ti o dara ju fun Standard duct / eriali, high-rodent risk Same as GYTS, lower weight Long-span aerial along power poles

Technical Specifications Across Trunk Cable Series

Paramita Iye
Fiber ite (aiyipada) G.652.D (nipa 90% of shipments); G.657.A1, G.657.A2, G.654.E and OM3 / OM4 / OM5 on request
Attenuation @ 1310 nm La 0.35 dB/km
Attenuation @ 1550 nm La 0.21 dB/km
Fiber count range 2 – 288 cores standard; titi di 576 cores custom (ADSS ni ilopo-jaketi)
O kere ju rediosi tẹ ≥ 10× cable diameter (aimi); ≥ 20× diameter (ìmúdàgba)
Long-term tensile strength GYTS/GYTA 600 N; Olusin-8 5 kN; Submarine 4 kN long-term / 10 kN installation
Itoju fifun pa ≥ 300 N/100 mm (armored series)
Awọn iwọn otutu ti nṣiṣẹ -40 si +70 °C (ita gbangba); -20 si +70 °C (indoor LSZH / PVC)
Design service life Outdoor armored 20 ọdun; ADSS double-jacket 25–30 years; submarine 25 ọdun
Idanwo 100% drum-by-drum attenuation test; OTDR trace archived per drum

Submarine Cable — Our Deep-Water Line ⭐

Our submarine cable line targets short-haul unrepeated systems — island interconnect, offshore platform tie-in, coastal loops — where a single-span 100 Gb/s link up to 500 km eliminates the cost of subsea repeaters, power feed and maintenance.

  • Depth rating: standard shallow-water build for up to 100 m (most common); deep-water build rated up to 8,000 m
  • Iwọn okun: titi di 288 awọn okun
  • Ihamọra: shallow-water uses hot-dip galvanized low-carbon round steel wire; deep-water uses high-carbon high-tensile round steel wire with zinc-aluminum alloy coating
  • Jakẹti: HDPE for seawater corrosion, water blocking and pressure resistance
  • Tensile: long-term 4 kN, short-term installation 10 kN
  • Ibamu awọn ajohunše: GB/T 18480, IEC 60794, ITU-T G.976, GJB 4489
  • Design service life: ko si kere ju 25 ọdun
  • Installation methods: trench burial (flat silt/sand seabed), surface laying (calm water), casing protection (rocky/reef zones), underwater suspension (bay spans)

Manufacturing Capability

Automated Production Lines with Inline Inspection

Our GYTS / GYTA lines run imported cabling machines, high-speed secondary coating equipment, and dual-layer co-extrusion jacket lines. Inline laser concentricity gauges and real-time OTDR scanners monitor every step. A three-stage water-blocking process controls excess fiber length, tape thermal bonding and jacket extrusion parameters through digital process control.

Annual Output & Stock Position

  • GYTS / GYTA: tens of millions of fiber-kilometers per year across all core counts, with 4–288-core standard configurations kept in stock
  • GYXTY: ~10,000 km per month
  • Indoor distribution cable: 5 production lines × 180 km per line per day
  • ADSS Single-Jacket: 12–48-core kept in stock; Moü 1 km
  • ASU: 2–24-core standard in stock; same-day shipping for regular configurations
  • Olusin-8: 2–48-core in stock across 4 dedicated extrusion lines

100% Drum-by-Drum Testing

  • Attenuation test on every drum before shipment — not sampling
  • Length tolerance strictly controlled within +1 si +2 metres per drum
  • Per-drum OTDR trace archived and provided to buyer on request
  • Tensile, water-penetration and aging test reports available under IEC 60794 ilana

Container Loading & Iṣakojọpọ

Standard drum length is 1–3 km per wooden reel for most trunk series; custom drum lengths supported on request. Approximate cable-length loading per container for figure-8 and similar profiles:

  • 20 GP container: 800 – 1,200 km of cable
  • 40 Hq container: 1,900 – 2,800 km of cable

Actual loading depends on cable diameter, drum size and stacking configuration — our sales team will calculate exact quantities against your PO.

Awọn iwe-ẹri ati Ibamu

  • ISO 9001 Didara Management System, factory-jakejado
  • IEC 60794 series — optical cable performance, environmental and mechanical test methods
  • YI — European conformity for applicable product lines
  • awọn / ETL — available for North American market entry
  • CPR — European Construction Products Regulation, for cables installed in permanent buildings
  • RoHS — hazardous substance compliance; certificates renewed annually
  • Submarine cable additionally complies with GB/T 18480, ITU-T G.976 and GJB 4489

Ohun elo ijẹrisi yatọ nipasẹ laini ọja ati ọja ibi-ajo. Jọwọ jẹrisi orilẹ-ede afojusun, agbegbe imuṣiṣẹ ati awọn iṣedede ti a beere nigbati o ba beere asọye.

Frequently Asked Questions About Fiber Optic Cable Sourcing

Q1. Kini iye aṣẹ ti o kere julọ?

Standard mọto USB MOQ ni 1 km. Kebulu pinpin inu ile tun 1 km MOQ; okun inu ile aṣa-awọ nbeere 5 km. USB submarine ojo melo bẹrẹ ni 100 km nitori iṣeto laini iṣelọpọ pataki. Teriba-Iru ju USB ọkọ lati boṣewa iṣura.

Q2. Kini akoko asiwaju boṣewa?

Deede 2–48-mojuto GYTS / GYTA / GYXTY / Awọn atunto ASU gbe lati ọja iṣura laarin awọn ọjọ. Aṣa okun kika, awọn ipari tabi awọn jaketi ti kii ṣe deede: ojo melo 15-25 ṣiṣẹ ọjọ da lori ilu ka. USB Submarine ati 288-core+ kọ nilo iṣeto-iṣẹ akanṣe.

Q3. Iwọn okun wo ni o lo bi aiyipada?

Nipa 90% ti awọn ọkọ oju omi okun wa ti pari pẹlu G.652.D nikan-mode okun. G.657.A1 ati G.657.A2 bend-inensitive grades jẹ aiyipada wa fun okun ti o ju silẹ ati awọn fifi sori aaye-mimu. G.654.E fun gun-gbigbe 400G+ ẹhin ati OM3 / OM4 / OM5 multimode for data-centre indoor cable are available on request.

Q4. Can you provide OTDR traces and test reports per drum?

Bẹẹni. Every drum ships after 100% attenuation testing, with the OTDR trace archived. Written test reports covering tensile, water penetration and thermal aging are available under IEC 60794 methodology on request — useful for project acceptance and customs clearance.

Q5. Can you customize drum length, colour and marking?

Bẹẹni. Standard drums are 1–3 km; longer runs supported on request (f.eks. ADSS in 500 m, 1200 m or segmented lengths). Jacket colour customization has a 5 km MOQ. Sequential metre marking, batch code and buyer logo can be printed to your specification.

faq

Q6. What certifications can you supply for European and North American markets?

Our cable ships with ISO 9001, YI, RoHS and IEC 60794 compliance as standard. awọn / ETL certifications are supported for North American entry; CPR is available for cable installed in permanent European buildings. Third-party test reports and country-specific certification can be arranged per project.

Q7. How do I choose between GYTS, GYTA, LTD, ADSS and ASU?

Short answer: lo GYTS tabi GYTA for standard duct / aerial trunk cabling; LTD when a non-metallic (unarmored) cable is required; ADSS nikan-jakẹti for aerial spans up to 300 m in temperate conditions, ni ilopo-jaketi for coastal salt-fog or ice-loaded spans; ASU for short-span aerial + duct dual-use where you want the strength of ADSS without the cost. Detailed matrix above.

Q8. Do you supply cables suitable for direct burial?

For direct burial we recommend GYTA53 (double-jacket with steel-tape armor) or GYTA with an additional PE protective conduit. Standard single-jacket ASU and ADSS are not designed for direct burial — the buried environment will corrode the jacket over time.

Q9. What is the warranty and service life?

Standard factory atilẹyin ọja ni 1 odun. Design service life: 20 years for standard outdoor armored cable; 25–30 years for ADSS double-jacket and submarine cable; 15 years for ASU with 1:1 defect replacement if the failure is traced to manufacturing.

Q10. How much cable fits in a shipping container?

For figure-8 and similar profiles: a 20 GP container carries approximately 800–1,200 km of cable; a 40 HQ carries 1,900–2,800 km. Exact loading varies with cable OD, drum size and stacking. Provide us the drum spec and we’ll calculate loading before the PO is placed.

Gba A Quick Quote

A yoo dahun laarin 12 wakati, jọwọ san ifojusi si imeeli pẹlu suffix "@fibconet.com".

Bakannaa, o le lọ si Oju-iwe Olubasọrọ, eyi ti o pese fọọmu alaye diẹ sii.