











Fibconet ku beetik 12 series of outdoor waterproof fiber optic connectors used in FTTH drop-cable terminations, FTTA base-station jumpers, and outdoor ODN cross-connect points. Product families cover IP65, IP67 and IP68 sealing grades, with housings in PA, PEI and metal, selected per model and per project environment.
All series are cross-compatible with mainstream OEM interfaces — Huawei, ZTE, Fiberhome, OPTAR, Chumbesajil completos, ODVA OptiTap, PDLC, NSN and ODC — so field crews can replace legacy assemblies without changing the enclosure or the drop-cable spec. Typical order size starts from 1,000 Pc; OEM labeling, custom pigtail lengths and bulk packaging are supported for distributors, ISPs and EPC contractors.
The sections below list our 12 series grouped by application, followed by the IP-rating selection logic, especificaciones técnicas, Buka'aj u ba'al u fabricación, Jejeláas k'at chi'ob, yéetel jump'éel beel cita.

Used to replace or extend existing Huawei / ZTE / Fiberhome / OPTAR / Fullaxs deployments. Interface geometry, keying and sealing follow the original OEM footprint so no adapter is needed.
| Serie | OEM Interface | Calificación IP | U búukinta'al típico |
|---|---|---|---|
| Huawei Compatible Fast-Connect | Huawei | IP68 | Replace Huawei legacy FTTx drop assemblies |
| Huawei Compatible Mini / Normal | Huawei (Mini + Normal size) | IP68 | Mixed-generation Huawei ODN sites |
| ZTE Compatible PEI Housing | ZTE | IP68 | ZTE-standard FTTH drops in tropical climate |
| Fiberhome Compatible G657A2 Kit | Fiberhome | IP65 | Fiberhome drop-cable pre-terminated kits |
| Fiberhome Compatible Pre-connected Kit | Fiberhome | IP65 / IP68 | Pole-to-home rapid deployment |
| OPT Compatible FTTA Connector | OPTAR | IP68 | Base-station jumper between BBU and RRU |
| Fullaxs Compatible PA Housing | Chumbesajil completos (Dúplex LC) | IP68 | Outdoor small-cell and RRU jumpers |
Follow ODVA / MSA industry standards rather than a single OEM. Preferred by North American ISPs and by carriers running multi-vendor networks.
| Serie | Estándar | Calificación IP | U búukinta'al típico |
|---|---|---|---|
| PDLC Optical Cable Assembly | PDLC (LC based) | IP67 | Outdoor patch-cord assemblies for FTTx |
| OptiTap Type B LC Connector | ODVA OptiTap | IP68 | North American FTTH multi-port terminals |
Terminated on site with no polishing, epoxy or oven. Cuts install time on a single drop from 20+ minutes to under 3 uchik.
| Serie | Método ku meyajo'ob | Calificación IP | U búukinta'al típico |
|---|---|---|---|
| IP68 SC/APC Field-Assembly OPT | Mechanical splice, tool-based | IP68 | Emergency repair, single-drop terminations |
| Z-Type PEI Waterproof Connector | Pre-embedded pigtail + Z sleeve | IP68 | Short-length drop cables, fast splice |
Passive coupler used inside outdoor enclosures or between two waterproof pigtails.
| Serie | Body | Calificación IP | U búukinta'al típico |
|---|---|---|---|
| Mini LC Waterproof Adapter with Copper | Copper sleeve, PA shell | IP67 | In-line splice inside outdoor closures |
The IP code from IEC 60529 defines protection against solids (first digit) yéetel ja' (second digit). For outdoor fiber, only the water digit varies in practice.
| Calificación | Water Test Condition | Typical Outdoor Use |
|---|---|---|
| IP65 | Low-pressure water jets from all directions | Wall-mount drop terminations under eaves; short-term rain exposure |
| IP67 | Immersion in 1 m of water for 30 uchik | Aerial and pole-mount drops; splash-heavy outdoor cabinets |
| IP68 | Continuous immersion beyond 1 m, condition set by manufacturer | Direct-buried joints; base-station RRU jumpers exposed to standing water and heavy monsoon rain |
Páaybe'en: IP68 is the only rating that lets the manufacturer define the immersion depth and duration. Always ask for the test report if a project spec calls out “IP68” without a depth value.
Material is selected per model, not per customer request. As a general rule:
| Parámetro | Ku típico | A'alaj |
|---|---|---|
| Grado u sellado | IP65 / IP67 / IP68 | Selected per series; IP68 depth reported per model on request |
| Compatibilidad yéetel láaj jo'ochiko'obe' | G.657.A1 / G.657.A2 / G.652.D | G.657.A2 is standard for FTTH drop cables |
| Connector end-face | SC leti' APC, LC LETI' APC, LC leti' UPC | APC preferred for FTTH to reduce return-loss impact |
| Asab inserción (mated pair) | ≤ 0.3 dB típico | Measured against a reference master jumper |
| Asab devolución | ≥ 60 Db (APC) / ≥ 50 Db (UPC) | Per Telcordia GR-326 |
| Temperatura funcionamiento | −40°C to +85°C | Per model — some FTTA-grade models qualified to +85°C |
| Retención cable (axial) | ≥ 50 N | Tuméen modelo; higher values available on FTTA series |
| Durabilidad ti' le acoplamiento | ≥ 500 Ciclos | Per Telcordia GR-326 |
| Xooko'obo' le carcasa | PA / PEI / metal-reinforced | Selected per model requirement |
Páaybe'en: values above are family-typical, ma' jump'éel ju'unil datos chéen-SKU. Ask us for the specific test report of the model you are quoting; k túuxtik yáanal le meyaj ku nu'ukulil modelo.
Fibconet’s parent operation in optical passive components dates back to 1994. The waterproof connector line was industrialized after the FTTx wave in China, and today ships to ISPs, EPC contractors and distributors in more than 40 noj lu'umo'ob.
Ferrules, sleeves and pigtails are sourced from long-term qualified suppliers. Housings are injection-molded in-house from qualified PA and PEI resins so batch-to-batch dimensional consistency stays under control. G.657.A2 drop-cable pigtails are supplied through our deep bare-fiber inventory and brand distribution partnerships.
Fibconet ku meyaj yáanal jump'éel ISO 9001 t.u.m gestión calidad. Product-level certification — RoHS, NÁAJAL, Telcordia GR-326 / GR-3120 test reports, and OEM-specific interface compatibility declarations — is issued per model and per project requirement. Túuxt to'on u mercado objetivo yéetel le tsoolol modelos, yéetel k suut le certificado aplicable establecido yéetel le cita.
Minimum order quantity starts at 1,000 pcs per model. Mixed-model orders are accepted above 3,000 pcs total.
Jaaj. Interface geometry, keying and sealing are built to the original OEM footprint. Field crews can plug our connector into the existing enclosure port without changing the drop cable or the sealing gel. We send a compatibility declaration with the first shipment on request.
IP67 is qualified for 30-minute immersion at 1 m depth. IP68 covers longer or deeper immersion under conditions the manufacturer defines. For aerial and wall-mount drops IP67 is enough; for direct-buried joints or base-station jumpers exposed to standing water, ask for IP68 with a stated depth.
Jaaj. G.657.A2 is our default for FTTH drop-cable pigtails because it holds transmission at a 7.5 mm radio u flexión. G.652.D and G.657.A1 are available if your project spec requires them.
Jaaj. Laser marking on the housing, custom color for the boot, and custom label on the bag and carton are available from 1,000 pcs per model.
Stock models ship in 5–7 working days. Custom pigtail length or OEM-labeled orders ship in 15–25 working days after order confirmation, u yaantal yo'osal u cantidad. Confirm the actual date on the pro-forma invoice.
Jaaj. Insertion loss and return loss are batch-tested and reported per carton. End-face 3D interferometry data and extended qualification reports (niebla salina, UV, thermal cycle) are provided on request or where the project tender requires them.
MOQ jach 1,000 pcs per model. Mixed-model orders are accepted from 3,000 pcs total, split across two or three models. This lets distributors trial multiple compatibility options in one shipment.
We ship FCA, FOB, CIF and DDP. DDP is quoted per destination country because of customs, VAT and last-mile handling; send us the delivery address and we return a landed cost quotation.
Family-typical value is ≥ 50 N. Selected FTTA and base-station models are qualified to a higher load. Ask us for the model-specific pull-test report before you tender a project.
Jaaj. Send the interface drawing, sealing gel spec and target IP grade under NDA. Our engineering team returns a feasibility assessment within 5 working days and a sample within 30 k'iin meyaj.
Responderemos ichil 12 horas, Much preste óolal ti' le correo electrónico yéetel le sufijo "@fibconet.com".
Beey xan, Je'el u páajtal a bin le Linki abas kaambal ti' máax ku, ku proporciona jump'éel formulario asab detallado.