











FIBCONET manufactures fiber optic vanaf die koperkabel-era in en varksterte across five product families — simplex & duplex indoor, waterproof drop, gepantser, MPO high-density, and ODF pigtails — with combined output exceeding 13 million cords per month. Every cord is 100% getoets vir invoegingsverlies, opbrengsverlies, tensile strength and end-face quality before packaging.
Our patch cords meet the corresponding test requirements defined in OVK 61300 (Klas U) en Telcordia GR-326-CORE (Klas R). Optical fiber comes from China’s four leading brands — YOFC, Ztt, Hengtong and Fiberhome. Ceramic ferrules use the CCTC series (Sumitomo ferrules available on request), and connector grades run from network-level to telecom-level to match your project’s cost and performance profile.
Beyond standard telecom cords, ons MPO / MTP high-density line supports 40G, 100G, 400G and 800G parallel optical transmission — the current mainstream for AI-driven data-centre buildouts and hyperscale MDA cabling. See the MPO section below.

| Reeks | Typical Use | Sleutel spesifikasies | Koppelaars |
|---|---|---|---|
| Indoor Simplex & Duplex Patch Cord | Data-centre patching, telecom room, cross-connect, in-cabinet routing | Insertion loss avg ≤ 0.3 dB; tensile 45 N; 2.0 / 3.0 mm baadjie; LSZH available | SC, LC, FC, ST, MU, MTRJ, E2000 — PC / UPC / APC |
| Buitelug & Waterproof Drop Patch Cord | FTTH drop, outdoor terminal box, CPRI fronthaul, base-station link | IP-rated seal; UV-resistant jacket; pre-connectorized options for 1–4 core drop | Mini SC, SC/APC, LC/APC waterproof |
| Armored & Anti-Rat Patch Cord | Data-centre under-floor, in-conduit runs, underground burial, harde omgewings | 201 stainless-steel spiral armor; tensile 140 N (2× standard); salt-spray 24 h; operating −40 to +85 °C | SC, LC, FC — UPC / APC |
| MPO / MTP High-Density Cord ⭐ | Data-centre MDA, AI compute cluster fabric, 40G/100G/400G/800G parallel optics, high-density cabinet | Op na 72 fibers per MPO; single-mode IL down to 0.15 dB; multimode low-loss ≤ 0.35 dB; ≥ 500 paringsiklusse | MPO / MTP male & female; hybrid MPO–LC / MPO–SC / MPO–FC breakout |
| Indoor Pigtail | ODF splicing, distribution box terminals, fusion-splice on-site | 0.9 mm buffered pigtail; Al die optiese en meganiese indeks voldoen aan die pleisterkoord 1.5 m length; custom lengths supported | SC, LC, FC — UPC / APC |
Every series above is 100% factory-tested (end-face, invoeging verlies, opbrengsverlies, tensile). Electronic test reports in FLUKE or EXFO format are available with each order.

| Pleister koord | Varkstert | |
|---|---|---|
| Connectorization | Connectors on both ends | Connector on one end only; other end bare fiber for fusion splicing |
| Primary use | Equipment-to-equipment or equipment-to-panel | ODF / distribution-box termination, fusion-spliced to the incoming cable |
| Lengte | Tipies 0.5 – 30 m; pasgemaak tot 300 m | Tipies 1.0 – 1.5 m; custom on request |
| Installasie | Plug-and-play | Requires fusion splicer on-site |
| Beste vir | Data centre patching, MDA, cross-connect, PON drop | Central office, ODF panel splicing, distribution frames |
We manufacture patch cords with all mainstream connectors: FC, ST, SC, LC, MU, MPO / MTP, E2000, MTRJ, SMA. End-face contact is available in three types:
For module ports, LC, SC and MPO / MTP dominate. LC is the default for high-density optical modules; SC is standard for FTTH; MPO handles high-count parallel links.
| Jacket type | Beste vir | Notas |
|---|---|---|
| Standard PVC | General indoor use | Lowest cost |
| Flame-Retardant PVC | Data centres, plenums with local fire code | Meets basic flame ratings |
| LSZH (Lae rook nul halogeen) | Data centres, telecom rooms, tonnels, subways | No halogens, low smoke, no corrosive gas — European & DC standard |
| LSZH Flame-Retardant | Strict fire-code data centres and public buildings | Combines LSZH with elevated flame retardance |
| 201 Stainless-Steel Armored | Buitelug, begrawe, rodent-prone, harsh environment | 140 N tensile; 24 h salt-spray |
Enkelkern (simpleks), dubbelkern (dupleks), and multi-core cables in 4, 6, 8, 12, 24, 48 en 72-kern konfigurasies. Custom core counts and lengths supported on request. Standard patch cord lengths run 0.5–30 m; custom lengths up to 300 m for special projects. Standard pigtail length is 1.0 – 1.5 m.
MPO / MTP is the connector platform driving the next decade of data-centre and AI cabling. A single MPO connector carries 8, 12, 16, 24, tot 72 vesels, replacing dozens of individual patch cords with one plug. Our dedicated MPO production runs 150,000 cords per month met 100% ferrule interferometer inspection and per-core polarity verification.
| Link Speed | Fiber Count Required | Tipe vesel | Bereik |
|---|---|---|---|
| 40G SR4 | 8 vesels (4Tx + 4Rx) | OM3 / OM4 | Op na 550 m (OM4) |
| 100G SR4 / SR10 | 8 of 20 vesels | OM3 / OM4 / OM5 | Op na 550 m |
| 400G SR8 / DR4 | 16 vesels / 8 vesels | OM4 / OM5 / enkel-modus | Op na 100 m (SR8) / 500 m (DR4) |
| 800G SR8 | 16 vesels | OM4 / OM5 | Op na 100 m — today’s AI cluster mainstream |
When you place an order, please confirm polarity type, gender configuration, connector-color scheme, and core-count breakout — our sales team will validate against your target optical modules before production begins.
| Parameter | betree die optiese vesel kommunikasie area |
|---|---|
| Test standard | OVK 61300 (Klas U); Telcordia GR-326-CORE (Klas R) |
| Invoeging verlies (tipies) | Standard ≤ 0.3 dB; low-loss grade ≤ 0.15 dB (MPO single-mode) |
| Opbrengsverlies | UPC ≥ 50 dB; APC ≥ 55 dB |
| Werkstemperatuur | −20 to +60 °C (Al die optiese en meganiese indeks voldoen aan die pleisterkoord); −40 tot +85 °C (gepantser & branch series) |
| Stoor temperatuur | −40 tot +85 °C |
| Paringsduursaamheid | SC / LC / FC ≥ 1,000 siklusse; MPO ≥ 500 siklusse |
| Trek sterkte | Standaard 45 N; tak 40 N (long-term); gepantser 140 N |
| Minimum bend radius | Standard cord 10 mm; MPO branch 15 mm static / 30 mm dynamic; armored 35–40 mm |
| Waarborg | 1-jaar fabriekswaarborg; design service life 10 betree die optiese vesel kommunikasie area |

| Reeks | Maandelikse Uitset |
|---|---|
| Simplex patch cord | 10,000,000 cords |
| Duplex patch cord (top-3 producer nationally) | 3,000,000 cords |
| MPO / MTP series | 150,000 cords |
| Breakout patch cord | 90,000 cords |
Optical fiber sourced from China’s four leading brands — YOFC, Ztt, Hengtong and Fiberhome — the same feedstock trusted by tier-1 operators worldwide. Ceramic ferrules are Sanhuan series by default, met Sumitomo ferrules available on request for the tightest concentricity requirements. Jacket compounds come from Shanghai Kaibo, a stable supplier to the same four fiber manufacturers.
Insertion-loss variation between production batches is held within ±0.08 dB. Colour consistency for OEM orders is managed by keeping a first-piece reference sample from every batch for direct comparison on subsequent orders.
Die toepaslikheid van sertifisering verskil volgens produklyn en bestemmingsmark. Please confirm target market and required standards when requesting a quotation.
Standard simplex and duplex patch cords have no MOQ — sample and trial orders are welcome. MPO cords typically start at 100 eenhede. Armored cords have a 1,000-piece MOQ due to armor tooling setup; delivery within 10 dae. OEM-printed packaging requires 5,000 pieces minimum.
Regular configurations of simplex, duplex and standard MPO ship from stock within days — we keep 2,000–3,000 pieces of common SKUs like SC/UPC duplex 2.0 mm LSZH in-stock. MPO custom orders: 7–12 days for a few thousand pieces; 15–20 days for orders above 20,000 stukke. Branch patch cords: samples ready in 3 dae.
Ja. Every cord ships with 100% factory testing (DIE, RL, end-face, tensile). Electronic test reports in FLUKE or EXFO format are available after order placement. 3D end-face inspection is standard on all MPO production and available on request for other cord types.
Standard-grade MPO: insertion loss ≤ 0.7 dB (multimodus 850 / 1310 nm). Low-loss grade: ≤ 0.35 dB average. Single-mode MPO with high-precision imported ferrules can reach IL as low as 0.15 dB for testing and telecom-grade applications. Standard grade covers enterprise networks and office cabling; low-loss grade is designed for high-density cabinet cabling and 100G+ mainstream links.
Ja. Standard MPO breakout defaults: 12-core → 6 duplex LC; 24-core → 12 duplex LC. Custom splits including 2×12, 3×8, 4×6 and other ratios are fully supported. MPO–MPO breakout allows up to 6 MPO connectors on a single end, with both ends symmetric. Trunk length range: 0.2 m aan 300 m; branch length differences within a single cable should stay within 30 cm to avoid fiber-stress attenuation drift.
Our MPO cords stably support 40G, 100G, 400G and 800G parallel optical transmission. This makes them suitable for current AI data-centre cluster fabric, hyperscale MDA cabling, and next-generation coherent transport buildouts. OM4 / OM5 multimode is the current mainstream for 400G / 800G SR8 links; single-mode covers longer reach and DR4 architectures.
Ja. Our patch cords meet the applicable UL, ETL and TUV test standards. Formal third-party certification can be arranged per project on request — test cost is quoted separately depending on the scope required.
Optical fiber from YOFC, Ztt, Hengtong and Fiberhome. Ceramic ferrules are Sanhuan by default; Sumitomo ferrules available on request. Connector grades range from network-level (mainstream cost-performance) to telecom-level (highest concentricity, lowest IL) — specify per project.
Our armored patch cords use a 201 stainless-steel spiral armor layer. Treksterkte bereik 140 N (versus 70 N for standard cords) and the armor passes a 24-hour salt-spray test, making them suitable for marine shipping and coastal deployments. Best for static routing with occasional bending — not recommended for high-frequency repeated flexing. For buried installations, an additional protective conduit is recommended to prevent long-term corrosion.
Ja. Ons produseer vir jou kunswerk - pasgemaakte kleur bokse, logo van buitekarton, private-etiket PE sakke, spesifikasieblad-insetsels en handelsmerkhandleidings. Neutral packaging is available with no minimum quantity. Printed packaging with custom logo requires 5,000 pieces minimum to justify plate setup.
Ons sal binne reageer 12 ure, let asseblief op die e-pos met die agtervoegsel "@fibconet.com".
Ook, jy kan gaan na die Kontak Bladsy, wat 'n meer gedetailleerde vorm verskaf.