フィブコネットのメーカー 12 series of outdoor fiber optic splice closures (also called joint closures, cable closures, or in field slang dome cans) for OSP splicing between feeder, distribution and drop cables. Capacity ranges from 12 cores for FTTH drop junctions up to 840 cores for backbone and long-haul splice points. Sealed to IP68, housings are PP+GF, PPR or metal-braced polymer with a 15 to 25-year design field life. Our passive optical component roots trace back to 1994, and the same in-house tooling and test discipline built for PLC splitters now runs the splice closure line.

Two body types cover the two OSP install methods: dome (vertical) closures for pole, wall and direct-buried joints, と 水平 (inline) closures for manhole, handhole and figure-8 aerial splice points. Selected dome models ship pre-loaded with 1×8 or 1×16 PLC splitters and act as PON hub points inside a Quick ODN / pre-terminated FTTH deployment. Enclosures accept mechanical, heat-shrink or silicone sealing per model.
以下のセクションでは、 12 models grouped by body type, then cover Dome-vs-Horizontal selection logic, 技術仕様, 製造能力, 梱包, よくある質問, そして引用チャネル.
Cylindrical body with a single base plate carrying all cable ports. Best suited to pole-mount, wall-mount and direct-buried joints where cables enter from one end. The two splitter-loaded models below double as PON hub points inside a Quick ODN deployment.
| モデル | Core Capacity | シーリング / 評価 | PON hub role | 一般的な使用方法 |
|---|---|---|---|---|
| IK10 IP68 96 Core Huawei-Compatible Access Terminal Closure | 96 コア | IP68 / IK10 impact | — | Huawei-standard access node, pole or wall |
| 96/144 Core Dome Closure (ポール / 壁 / 地下) | 96–144 cores | IP68 | — | Multi-scenario OSP splice, any mount |
| 96/144 芯 100 kPa 25-Year Splice Closure | 96–144 cores | IP68 / 100 kPa air-pressure hold | — | Long-life backbone joints requiring pressure test |
| 144 Core Metal-Bracket IP68 Dome Closure | 144 コア | IP68 | — | Metal-braced tray for high-vibration or heavy cable load |
| IP68 288 Core High-capacity Dome Closure | 288 コア | IP68 | — | High-density backbone splice point |
| 1:8 / 1:16 PLC Splitter IP68 Dome (22000 N / 10 cm cable retention) | Splitter-loaded dome | IP68 / 22000 N cable pull | Yes — Quick ODN hub | PON hub combining splice and 1×8 or 1×16 splitting |
| IP68 1:8 PLC Splitter Pre-terminated FAT Closure | スプリッター + FAT ports | IP68 | Yes — pre-terminated PON hub | Plug-and-play PON hub with drop-cable ports |
Elongated body with cable ports at both ends. Preferred for manhole, handhole, aerial figure-8 span and any splice point where cables enter and exit in the same axis.
| モデル | Core Capacity | シーリング / 評価 | 一般的な使用方法 |
|---|---|---|---|
| PP+GF / PPR IN-LINE 2-in-2-out 12 コアスプライスの閉鎖 | 12 コア | IP68 / mechanical seal | FTTH drop junction, aerial or handhole |
| 48 Core 1-in-2-out Inline Cable Closure | 48 コア | IP68 | Small branch inline splice |
| 15+ Service Years PP+GF IP68 2-in-2-out Inline Closure | まで 96 コア | IP68 / 15+ years field life | Mid-density distribution splice with long life claim |
| 96 Core Silicone-Protection Horizontal Splice Closure (カスタマイズされた) | 96 コア | IP68 / silicone sealing | Manhole splice with elevated moisture and chemical exposure |
| 576 / 840 Core Heat-Shrink Seal IP68 Cable Closure | 576–840 cores | IP68 / 熱収縮 | Long-haul backbone splice, high-count ribbon or loose-tube |
A splice closure protects, seals and organises spliced fibers at any point along an OSP cable route. The body shape follows the physical install location, not the fiber count.
| Dome (Vertical) | Horizontal (Inline) | |
|---|---|---|
| ケーブル差込口 | All ports on one base plate | Ports at two opposite ends |
| Best install | ポール, 壁, 直接埋設, hand-hole from top | マンホール, aerial figure-8 span, tray-mount inline |
| Typical core count | 96, 144, 288 — expandable via added trays | 12, 48, 96, 576, 840 — scales with body length |
| Access | Lift the dome, all splice trays exposed | Split the shell, access trays along the axis |
| PLC splitter loading | Common (PON hub role) | Less common, used mainly for pure splice |

| Core capacity | Network role | Body type shortlist |
|---|---|---|
| 12–48 cores | FTTHドロップ / distribution junction | Inline, mechanical seal |
| 96 コア | Access-layer PON node, base-station splice | Dome (Huawei-compatible or metal-bracket) |
| 144 コア | Distribution-layer aggregation | Dome, tray-expandable |
| 288 コア | Metro backbone splice point | Dome, 大容量 |
| 576–840 cores | 長距離バックボーン, high-count ribbon | Inline, heat-shrink seal |
ノート: the values below are family-typical ranges across the 12 シリーズ, 単一 SKU データシートではない. RFQ段階でモデル固有のテストレポートをリクエストしてください; モデルの部品番号でお送りします.
| パラメータ | 標準値 | コメント |
|---|---|---|
| Core capacity | 12 に 840 コア | モデルごと; expandable via added splice trays |
| ハウジング材質 | PP+GF, PPR, ABS+PC or metal-braced polymer | Selected per model and environment |
| シールグレード | IP68 | All outdoor OSP models |
| 耐衝撃性 | Up to IK10 on selected models | Metal-bracket and IK10-rated series |
| シール方法 | 機械式 / 熱収縮 / silicone | モデルごと |
| Air-pressure hold | 100 kPa on selected models | For pressurised OSP networks |
| ケーブル保持 (axial pull) | まで 22,000 N / 10 cm on selected models | Splitter-loaded dome rated for heavy pull |
| Cable entry ports | 1-インツーアウト, 2-インツーアウト, 4-in-4-out per model | Additional ports available on custom builds |
| Main cable diameter | Typically Φ7–Φ16 mm | Model-dependent; branch cable Φ5–Φ11.5 mm |
| スプライストレイ | Stackable, 12 また 24 splices per tray | Both fusion and mechanical splice trays supported |
| 動作温度 | −40℃〜+65℃ | Storage −35°C to +55°C per shipping spec |
| Design field life | 15 に 25 years outdoor | モデルごと; PP+GF with UV additive supports 25 年 |
| Reference test standards | IEC 61753-1, YD/T 814, GR-771 | Applied per project requirement |
Fibconet’s optical communication background traces back to the early 1990s. Our passive optical component manufacturing roots start in 1994 with a PLC splitter factory; the company was formally structured in 2000 and today operates with 300+ core staff and an extended multi-site manufacturing network of up to 800 スタッフとエンジニア across China. The same tooling and test discipline built for high-count PLC splitter production now runs the splice closure line, including injection molding of PP+GF and PPR housings, splice tray forming, and full-load assembly.
Splice closures are only as reliable as the materials inside them. 組み立てステップだけではなく、上流のスタックを制御します:

Fibconet operates under an integrated ISO 9001 / ISO 14001 / ISO 45001 management system covering quality, environment and occupational health & 安全性. 原材料の RoHS レポートは出荷ごとにデフォルトで提供されます.
Product-level compliance is issued per model and per target market. Depending on the model list and destination country, we can support これ, RoHS, 到着, the, ETL, 心肺蘇生法, ANATEL, CCA, TLC and other market-entry documents. Applicable test reports against IEC 61753-1, YD/T 814 と Telcordia GR-771 reference standards are provided at project scale.
Certification applicability varies by product and project requirements. ターゲット市場とモデルリストをお送りください。, and we return the applicable certificate set with the quotation.
All four are the same product family — an outdoor enclosure that houses and seals spliced fibers along an OSP cable route. “Splice closure” と “joint closure” are the standard English terms. “Dome can” と “炮筒” are field slang for the dome (vertical) body style. The Chinese term “熔接包” refers to the same category and is common in Chinese-language RFQs from Southeast Asia and Africa.
A splice closure protects and organises spliced fibers along an OSP cable route; there is no active drop-cable termination for subscribers. A distribution box (太い) terminates drop cables into adapter ports and often houses the last-mile splitter. Splice closures sit deeper in the network; distribution boxes sit at the drop point closest to homes.
Choose dome when cables enter from a single direction — pole-mount, 壁掛け, 直接埋設, or hand-hole accessed from above. Choose inline when cables enter and exit along the same axis — manhole splice, aerial figure-8 span, or tray-mount along a linear run.
Match the closure to the largest cable at the splice point plus a spare tray for future expansion. FTTH drop junctions typically use 12–48 core inline closures. PON access nodes use 96–144 core dome closures. Metro backbone splices use 288 コア; long-haul trunk splices use 576 また 840 cores in heat-shrink inline bodies.
For direct-buried and pressurised networks, use a mechanical-seal dome with 100 kPa air-pressure hold; the seal is verifiable in the field and re-enterable for future splice work. Heat-shrink is more permanent but not re-enterable without cutting.
はい. Dome closures can be shipped with a 1×8 or 1×16 PLC splitter pre-terminated at factory. ザ 1:8 / 1:16 PLC Splitter Dome model is rated for 22,000 N / 10 cm cable retention so the housing tolerates heavy drop-cable pull. Splitter chips are Shijia or Korean-source, and pigtails use G.657.A2 fiber from major Chinese fiber brands.
PP+GF and PC+ABS housings with a UV stabiliser additive package hold 15 に 25 years of outdoor service, depending on model. Ask us for the specific model’s material spec if your project tender requires a stated design life.
はい. IEC 61753-1, YD/T 814 and GR-771 test reports are available per model. Raw material RoHS reports ship by default. Market-entry certificates such as CE, 到着, the, ETL, 心肺蘇生法, ANATEL, CCA and TLC are issued per model and per target market. If a certificate you need is not already on file, プロジェクト規模でサードパーティのテストを手配できます.
MOQ starts at 100 pcs on standard configuration; custom builds are typically 500–1,000 pcs. Standard orders ship in 15–25 days; custom builds in 25–40 days. [TBC: confirm exact values per model at RFQ stage.]
はい. Pole-mount and wall-mount hardware is included on the dome closures. Aerial figure-8 mounting kits for inline closures are supplied on request. Manhole tray mounts and cable-management brackets are quoted with the closure.
はい. Our splitter-loaded dome closures — the 1:8 / 1:16 PLC Splitter Dome and the pre-terminated FAT closure — act as PON hub points inside a Quick ODN system. They pair with our pre-terminated drop cables, MPOハブ, sub boxes and asymmetric splitters to reduce on-site splicing, cut installation labor, and make FTTH rollout more predictable. If your project is a new FTTH build in a labor-cost-sensitive market, ask for a matched Quick ODN configuration when you send the RFQ.
光ファイバーチューブスプリッター 12 光ファイバーチューブスプリッター, 光ファイバーチューブスプリッター 光ファイバーチューブスプリッター.
光ファイバーチューブスプリッター, 光ファイバーチューブスプリッター 光ファイバーチューブスプリッター, 光ファイバーチューブスプリッター.