Edit Translation
Quaerere

Parva forma factor pluggable transceiver

Forma parva pluggable factor- (SFP) hoc pacto, calidum-pluggable network interface moduli usus est ad telecommunicationem et data communicationis socialis applicationes.
525px-10_Gbit XFP et SFP transceivers
Tabula contentorum

Small form-factor pluggable(SFP) hoc pacto, hot-pluggable network interface module.

It is used for both telecommunication and data communications applications.

The form factor and electrical interface are specified by a multi-fonte consensu (MSA) auspiciis formae parvae Committee.

Est popularis industriae forma coniunctim evoluta et sustentatur multis retis componentibus concionatorum.

Commodum usura SFPs loco certo interfaces (e.g. modularis connexiones in Aer permutat) is that

the interface port can be equipped with any suitable type of transceiver as needed.

To connect a fiber optic cable or copper cable,

SFP interface in networking hardware modularis est (plug quod lascivio) slot for a media-specific transceiver.

SFP transceivers est synchrona optical networking supporting (SONET),

Gigabit Ethernet, Fibra Channel, MON, et alia signa communicationis.

In introduction, typical celeritates erant 1 Gbit / s Aer SFPs et usque ad 4 Gbit/s for Fibre Channel SFP modules. In 2006,SFP+ specificationem celeritates ad X Gbit / s etSFP28 iteration is designed for speeds of 25 Gbit/s. The SFP replaced the larger GBIC in most applications and has been referred to as aMini-GBIC ab aliquo concionatorum.

Aliquanto maior frater est quattuor lane Quad parva forma factor Pluggable (QSFP). The extra lanes allow for speeds 4 temporibus correspondentes SFP *. In 2014, the QSFP28 variant was published allowing speeds up to 100 Gbit/s.

In 2019, the related QSFP56 was standardized doubling the top speeds to 200 Gbit / s cum products iam vendere a major venditores.

Sunt adaptatores vilia permittens SFP transceivers in QSFP portum collocari.

tum aSFP-DD, quae concedit pro C Gbit / s per duos vicos, tum a *QSFP-DDspecifications, quae concedit pro CD Gbit / s super octo vicos, editae sunt.

These use a formfactor which compatible to their respective predecessors.

Vel certandi solution,

theOSFP (Octal Small Format Pluggable) transceiver is also intended for 400 Gbit/s fiber optic links

between network equipment via 8 × 50 Gbit/s electrical data lanes.

Versio paullo maior est quam formfactor QSFP quae tractandi maioris potentiae outputs capax est. Vexillum OSFP initio Kalendis Novembribus denuntiatum est 15, 2016. Eius fautores dicunt adaptor humilis sumptus permittit ad convenientiam moduli QSFP.

SFP Genera

SFP transceivers praesto sunt cum varietate transmissionis et speciei recipientis, permittens users eligere oportet transceiver ad sulum nexum praebere requirituroptical semoto optical fibra praesto per genus (e.g. multi modus alimentorum fibra vel unius modus fibra). Transceptores etiam per transmissionem velocitatis designantur. SFP modules are commonly available in several different categories.

NomenStandardintroducedStatusMagnitudoretrorsum compatibleMAC angustos ad PHY chipMediaConnectorMax channelsNotae
100 Mbit/s SFPSFF INF-8074i2001-05-01current113.9 mm2nullusMIIFibre, cuprumLC, RJ451
1 Gbit/s SFPSFF INF-8074i2001-05-01current113.9mm2100 Mbit/s SFP*SGMIIFibre, cuprumLC, RJ451
1 Gbit/s cSFPcurrent113.9mm2FibreLC2
10 Gbit/s SFP+SFF SFF-84722002-08-01current113.9mm21 Gbit/s SFPXGMIIFibre, cuprum, DACLC, RJ451
25 Gbit/s SFP28SFF SFF-84022014-09-13current113.9 mm210 Gbit/s SFP+Fibre, DACLC1
50 Gbit/s SFP56current113.9 mm2Fibre, DACLC1
4 Gbit/s QSFPSFF INF-84382006-11-01current156 mm2nullusWWII4
40 Gbit/s QSFP+SFF SFF-86832012-04-01current156 mm2nullusXGMIIFibre. DACLC, MTP / MPO4CWDM
50 Gbit/s QSFP28SFF SFF-86652014-09-13current156 mm2QSFP +Fibre, DACLC2
100 Gbit/s QSFP28SFF SFF-86652014-09-13current156 mm2nullusFibre, DACLC, MTP/MPO-124CWDM
200 Gbit/s QSFP56SFF SFF-86652015-06-29current156 mm2nullusFibre, DACLC, MTP/MPO-124
400 Gbit/s QSFP-DDSFF INF-86282016-06-27current156 mm2QSFP +, QSFP28Fibre, DACLC, MTP / MPO-168CWDM

100 Mbit/s SFP

  • Multi modus fibra, LC connector, cum nigreos or * Beige color coding
    • SX - 850 nm, ad maximum DL m *
  • Multi modus fibra, LC connector, cum caeruleum color coding
    • FS^  - 1300 nm, ad spatium usque ad V km.
    • LFX (Nomen dependens manufacturer) - 1310 nm, ad spatium usque ad V km.
  • Unius modus fibra, LC connector, cum caeruleum color coding
    • LX - 1310 nm, nam distantiae usque ad X km
    • EX - 1310 nm, nam distantiae usque ad XL km
  • Unius modus fibra, LC connector, cum viridis color coding
    • ZX - 1550 nm, nam distantiae usque ad LXXX km, (secundum fibra iter detrimentum)
    • EZX - 1550 nm, nam distantiae usque ad CLX km (secundum fibra iter detrimentum)
  • Unius modus fibra, LC connector, Bi-directional, cum caeruleum et flavum color coding
    • BX (publiceBX10) - 1550 nm/1310 nm, Fibra BI-directional 100 Mbit SFP Transceivers, excipereBX-U (caeruleum) etBX-D (flavum) nam uplink et downlink respectively, et pro distantiis usque ad X km. Variationes bidirectionales SFPs fabricatae sunt etiam quae potestatem versiones superiores transmittunt cum facultates longitudinis usque ad 40 km..
  • Aeris tortilis par cabling, 8P8C (RJ-45) connector
    • 100BASIS TX - pro distantiis usque ad 100m.

1 Gbit/s SFP[edit]

  • 1 Gbit/s multi-modus fibra, LC connector, apud nigrum vel beige extractionem vecte
    • SX - 850 nm, ad maximum 550 m ad 1.25 Gbit/s (gigabit Ethernet). Aliae multi-modi applicationes SFP vel superiores rates in distantiis brevioribus sustinent.
  • 1.25 Gbit/s multi-modus fibra, LC connector, extractionem vecte colorum non de mensuris
    • SX+/MX/LSX (Nomen dependens manufacturer) - 1310 nm, ad spatium ad II km *. Non compatible cum SX vel 100BASE-FX. Fundatur in LX, sed machinator ad operandum cum fibra multi-modi utens vexillum multimodis panni rudis potius quam funem modum conditionatum communiter LX ad multimodis accommodare..
  • 1 to 2.5 Gbit / s fibra una-modus, LC connector, ex hyacintho extraction vecte
    • LX - 1310 nm, nam distantiae usque ad X km (primum, LX sicut operuit V km andLX10 ad X km secuta est postea)
    • EX - 1310 nm, nam distantiae usque ad XL km
    • ZX - 1550 nm, nam distantiae usque ad LXXX km (secundum fibra iter detrimentum), apud viridis extraction vecte (vide GLC-ZX-SM1)
    • EZX - 1550 nm, nam distantiae usque ad CLX km (secundum fibra iter detrimentum)
    • BX (publiceBX10) - 1490 nm/1310 nm, Single Fiber Bi-Directional Gigabit SFP Transceivers, excipereBX-U etBX-D nam uplink et downlink respectively, et pro distantiis usque ad X km. Variationes bidirectionales SFPs etiam conficiuntur, quae 1550 um in unam partem utuntur, et altius transmittendum potestatem versiones cum capabilities longitudinis usque ad 80 km.
    • 1550 nm 40 km (XD), 80 km (ZX), 120 km (EX or *EZX)
    • SFSW - una-fibra transceivers unum esse, quia bi-directional negotiationis in uno fibra. Copulata CWDM, haec duplices negotiatio densitas fibrarum nexuum.
    • Crassum necem multiplexing divisio- (CWDM) et densa adsum multiplexing-division (DWDM) transceivers in variis aequalitatem maximis variis intervallis. CWDM and DWDM transceivers usually support link distances of 40 km, 80 km and * 120 km.
  • 1 Gbit / s pro aeris retorta-par cabling, 8P8C (RJ-45) connector
    • 1000BASIS-T - horum modulorum incorporandi significantes ambitum interfaciei corporis pro Coding Sublayer recoding et modo adhiberi potest pro gigabit Aer ob lineae specificae codicem. Non compatitur (vel potius: non adumbrari) Fibra Channel vel SONET. Secus non-SFP, aeris 1000BASE-T portus in plures iter et virgas insertas, 1000BASIS-T SFPs non potest operari in velocitatibus 100BASE-TX.
  • 100 Mbit/s aeris et optici - nonnulli venditores 100 Mbit/s limitata SFPs in fibra-ad applicationes domus terminatas conscenderunt et in reposito ambitus legatorum 100BASE-FX cadunt.. Hae relative inusitatae sunt et facile cum 100 Mbit/s SFPs . confundi possunt.
  • Etsi non memoratur in aliquo documento officiali specificationis, maxima certe notitia originalis SFP vexillum est 5 Gbit/s. Hoc tandem ab utroque 4GFC Channel Fiber et DDR Infiniband, praesertim in quatuor laneis QSFP forma adhibitum..
  • Nuper, SFP transceivers creata sunt quae 2.5 Gbit/s et 5 Gbit/s ethernet celeritates cum SFPs cum 2.5GBASE-T permittunt. et 5GBASE-T.

10 Gbit/s SFP+

A 10 Gigabit Ethernet XFP transceiver et SFP+ transceiver iuxta latus.

TheSFP+ (auctus parva forma factor pluggable) auctus est versio SFP quae subsidia data rates usque ad XVI Gbit / s *. SFP + specificatio prima die mensis Maii editum est 9, 2006, et versionem 4.1 pridie Idus Julij editum 6, 2009. SFP+ subsidia 8 Gbit/s Fibre Channel, 10 Gigabit Ethernet and Optical Transport Network vexillum OTU2. Popularis industriae forma multis retis componentibus concionatorum fulcitur. Etsi vexillum SFP+ non includit mentionem 16 Gbit/s Fibrae Channel, hoc celeritate adhiberi potest.

SFP+ etiam inducit directum attachiamentum pro connectendo duos SFP+ portus sine transceivers dedicatis. Direct attach rudentes (DAC) est in passivo (usque ad 7 m), active (usque ad 15 m), et active optical (AOC, usque ad 100 m) variantes.

10 Gbit/s SFP + modulorum sunt prorsus eaedem dimensiones ac regulares SFPs, permittens apparatu manufacturer ut re- uti existentium in corporeis consiliis 24 et XLVIII-portum permutat et modulari linea cards. Prae ad priorum modulorum XENPAK vel XFP, SFP+ moduli plures ambitum relinquunt ut efficiantur in tabula hospitis loco intra moduli. Per usum adaptoris electronic activi, SFP + modulorum usus in vetustiore instrumento cum XENPAK portubus[30] et x2 portus.

SFP + modulorum describi potestliberum or *lineari types; hoc describitur functionality ex inbuilt electronics. Limitandi SFP + modulorum signum amplificati includit ut re-figurare possit (degradatus) accepit signum cum linearibus sunt non. Moduli lineares maxime usi sunt cum signis humilibus Sed ut 10GBASE-LRM; aliter, limitandi modules praeferuntur.

25 Gbit/s SFP28

SFP28 est 25 Gbit/s interface quae evolvit e instrumento 100 Gigabit Ethernet quod typice impletur 4 per XXV Gbit / s data vicos. Identical in mechanica ratione SFP et SFP +, SFP28 instrumentum unum 28 Gbit/s laneaccommodato XXV Gbit / s de notitia per modum translitterandi caput.

SFP28 modules existunt supporting singula- aut multi-modus alimentorum fibra, active optical funem ac directum attach aeris.

cSFP

Thepacto parva forma factor pluggable (cSFP) Est versio SFP cum eadem forma mechanica permittens duos canales per portum independens bidirectional. Praecipue ad densitatem et diminutionem fibrarum usus per portum auget.

SFP-DD

Theparva forma factor pluggable duplici densitate (SFP-DD) multi fons pactum est novum vexillum ad portum densitatis duplicare. Secundum SFD-DD MSA website: "Network apparatu fundatur in SFP-DD legatum SFP modulorum et funerum sustinebit", et densitas duplex novum products. "

QSFP types

QSFP+ 40 Gb Transceiver

Quad parva forma factor Pluggable (QSFP) transceivers praesto sunt cum variis generibus transfusor et accipientis, permittens users eligere oportet transceiver ad sulum nexum praebere requirituroptical semoto per multi-modus vel unius modus fibra.

4 Gbit/s QSFP

Documentum originale QSFP certa quattuor canales portantes Gigabit Ethernet, 4GFC (FiberChannel), vel DDR InfiniBand.

40 Gbit/s QSFP+

QSFP+ est evolutio QSFP ad quattuor 10 Gbit/s canales portantes 10 Gigabit Ethernet, 10GFC FiberChannel, vel QDR InfiniBand. The 4 canales etiam coniungi possunt in unum 40 Gigabit Ethernet link.

50 Gbit/s QSFP14

Vexillum QSFP14 ad portandum FDR InfiniBand, SAS-3. vel 16G Fiber Channel

100 Gbit/s QSFP28

QSFP28 vexillum ferre 100 Gigabit Ethernet est, EDR InfiniBand, vel 32G Fiber Channel. Aliquando hoc genus transceptoris etiam "QSFP100" vel "100G QSFP" refertur. propter simplicitatem.

200 Gbit/s QSFP56

QSFP56 200 Gigabit Ethernet est ad portare, HDR InfiniBand, vel 64G Fiber Channel. Maxima amplificatio est quod QSFP56 utitur quattuor gradibus pulsus amplitudine modulationis (PAM-4) pro non-reditus-ad-nullus (NRZ). Utitur eisdem specificationibus corporis ac QSFP28 (SFF-8665), cum determinationibus electricis ex SFF-8024 et 2.10a recognitione SFF-8636. Transceiver quandoque hoc genus refertur ad "200G QSFP" propter simplicitatem.

Fanout

Commutatio et itineris fabrica exsequendi QSFP+ portus in suis productis saepe patitur usum unius QSFP+ portus quasi quattuor independentes 10 gigabit nexus ethernet, density valde augendae portum. Exempli gratia, a typicam 24-portum QSFP + 1U switch esse possit ad opera 96x10GbE hospites. Exstant etiam funes fanout qui unum portum QSFP28 accommodant ad quatuor independentes 25 gigabit ethernet SFP28 portus. (QSFP28-ad-4×SFP28) itemque rudentes unum portum QSFP56 accommodare ad quattuor independentes 50 gigabit ethernet SFP56 portubus (QSFP56-ad-4×QSFP56).

Applications

Aer switch duabus foraminibus inanis SFP (Infra sinistram)

SFP bases in Aer virgas, iter, firewalls et network interface cards. Adhibentur in Fibre Channel hospitem adaptors et repono apparatu. Propter humilis sumptus, humilis profile ", et facultatem praebere nexum ad genera fibra optica, SFP tali apparatu auctus flexibilitate.

Standardization

SFP transceiver non normatum ab aliquibus signis officialibus corporis, sed potius per consensum multi-fontis specificatur(MSA) in competing manufacturers. SFP designatus est post GBIC interface, et maiora conceditportum density (numerus transceivers per datum spatium) quam GBIC, quam ob rem etiam SFP mini-GBIC notum est.

tamen, sicut practicum, machinatores aliquos artifices retis in exercitiis vendor cincinnis exercent quibus compatibilitatem cum "generico" SFPs consulto frangunt, perscriptio in firmware machinae addito quae modo proprios modulos venditoris efficient. Tertia factio SFP fabricatores SFPs cum EEPROMs induxerunt, qui programmaverunt ut cuilibet venditori ID par.

Color coding SFP

Color coding SFP

ColorStandardMediaadsumNotae
nigreosINF-8074Multimode850 nm
BeigeINF-8074Multimode850 nm
nigreosINF-8074Multimode1310 nm
caeruleumINF-8074Singlemode1310 nm
rubrumproprietatis
(non SFF *)
Singlemode1310 nmUsus est in 25GBASE-ER
Viridisproprietatis
(non SFF *)
Singlemode1550 nmUsus est in 100BASE-ZE
rubrumproprietatis
(non SFF *)
Singlemode1550 nmUsus est in 10GBASE-ER
albumproprietatis
(non SFF *)
Singlemode1550 nmUsus est in 10GBASE-ZR

Color coding of CWDM SFP

ColorStandardadsumNotae
Gray1270 nm
Gray1290 nm
Gray1310 nm
Viola1330 nm
caeruleum1350 nm
Viridis1370 nm
flavus1390 nm
Orange1410 nm
rubrum1430 nm
Brown1450 nm
Gray1470 nm
Viola1490 nm
caeruleum1510 nm
Viridis1530 nm
flavus1550 nm
Orange1570 nm
rubrum1590 nm
Brown1610 nm

Color coding of BiDi SFP

NomenStandardParte Color TX *Parte necem TX *Parte B Color TX *Latus V necem TXNotae
1000BASIS-BX*caeruleum1310 nmPurpura1490 nm
1000BASIS-BX*caeruleum1310 nmflavus1550 nm
10GBASE-BX*
25GBASE-BX*
caeruleum1270 nmrubrum1330 nm
10GBASE-BX*album1490 nmalbum1550 nm

Color coding of QSFP

ColorStandardadsumMultiplexingNotae
BeigeINF-8438850 nmNo
caeruleumINF-84381310 nmNo
albumINF-84381550 nmNo

annuit

Ante conspectum moduli SFP cum integrato LC iungo. Vectis extractio caerulea indicat modulus usus cum fibra optica singularis.

OC-3 SFP internus. Summitatem, theca metallica est tradens laser diode, imo, plastic theca est accepto photo diode.

The SFP transceiver contains a printed circuit board with an edge connector with 20 pads quae coeunt in tergo cum SFP electrica iungo in militiae systema. QSFP est 38 pads comprehendo 4 summus velocitas transmittunt data paria 4 summus celeritas data paria.

Mechanica dimensiones

Parte intuitu SFP moduli. Profundum, longissimum dimensionem, est 56.5 mm (2.22 in).

Dimensiones physicae SFP transceiver (et in subsequenti velocius variantes) angustiores postea QSFP counterparts, quod permittit SFP transceivers in QSFP portubus collocari per insumptuosus adaptor. Ambo minores quam XFP transceiver.

SFPQSFPXFP
mminmminmmin
Altitudo8.50.338.50.338.50.33
Latitudo13.40.5318.350.72218.350.722
Profundum56.52.2272.42.8578.03.07

EEPROM informationes

SFP MSA describit tabulam memoriae 256 byte in EEPROM describens facultates transceiver, vexillum interfaces, Huawei Compatible Mini Sc/APC Simplex IMPERVIUS Ipscapc Connector, et alia notitia, quod est pervium per Vide I²C interface ad 8-bit inscriptio 1010000X (A0h*).

Diagnostics digitales vigilantia

Moderni opticales SFP transceivers vexillum digital diagnostica monitoring support (DDM) munera. Haec factura etiam nota est ut magna vigilantia digitalis optical (DOM). Haec facultas permittit vigilantia SFP parametris operating in tempore reali. Paramters includit potentia output optical, optical initus virtutis, temperatus, laser Praeiudicia current, et transceiver copia intentione. In network apparatu, Haec notitia typice facta est available per Simplex Network Management Protocollum(SNMP). A DDM interface permittit finem utentium ad ostentationem diagnostica data et terrores transceivers fibrarum opticorum et ad egritudinem adhiberi potest quare transceiver non operatur.

Adepto Velox Quotes

Respondebimus intus 12 horae, Quaeso operam email cum suffixo "@fibconet.com".

Also, potes ire ad Contactus Page, quae accuratiorem formam praebet.