Fibconet gamina 12 series of outdoor waterproof fiber optic connectors used in FTTH drop-cable terminations, FTTA base-station jumpers, and outdoor ODN cross-connect points. Product families cover IP65, IP67 and IP68 sealing grades, with housings in PA, PEI and metal, selected per model and per project environment.
All series are cross-compatible with mainstream OEM interfaces — Huawei, ZTE, Fiberhome, OPT, Fullaxs, ODVA OptiTap, PDLC, NSN and ODC — so field crews can replace legacy assemblies without changing the enclosure or the drop-cable spec. Typical order size starts from 1,000 vnt; OEM labeling, custom pigtail lengths and bulk packaging are supported for distributors, ISPs and EPC contractors.
The sections below list our 12 series grouped by application, followed by the IP-rating selection logic, techninės specifikacijos, gamybos pajėgumas, DUK, ir citatos kanalą.

Used to replace or extend existing Huawei / ZTE / Fiberhome / OPT / Fullaxs deployments. Interface geometry, keying and sealing follow the original OEM footprint so no adapter is needed.
| Serija | OEM Interface | IP įvertinimas | Tipiškas naudojimas |
|---|---|---|---|
| Huawei Compatible Fast-Connect | atsirado mūsų trys viename lauko šviesolaidinio ryšio keitiklis | IP68 | Replace Huawei legacy FTTx drop assemblies |
| Huawei Compatible Mini / Normal | atsirado mūsų trys viename lauko šviesolaidinio ryšio keitiklis (Mini + Normal size) | IP68 | Mixed-generation Huawei ODN sites |
| ZTE Compatible PEI Housing | ZTE | IP68 | ZTE-standard FTTH drops in tropical climate |
| Fiberhome Compatible G657A2 Kit | Fiberhome | IP65 | Fiberhome drop-cable pre-terminated kits |
| Fiberhome Compatible Pre-connected Kit | Fiberhome | IP65 / IP68 | Pole-to-home rapid deployment |
| OPT Compatible FTTA Connector | OPT | IP68 | Base-station jumper between BBU and RRU |
| Fullaxs Compatible PA Housing | Fullaxs (LC dvipusis) | IP68 | Outdoor small-cell and RRU jumpers |
Follow ODVA / MSA industry standards rather than a single OEM. Preferred by North American ISPs and by carriers running multi-vendor networks.
| Serija | Standartinis | IP įvertinimas | Tipiškas naudojimas |
|---|---|---|---|
| PDLC Optical Cable Assembly | PDLC (LC based) | IP67 | Outdoor patch-cord assemblies for FTTx |
| OptiTap Type B LC Connector | ODVA OptiTap | IP68 | North American FTTH multi-port terminals |
Terminated on site with no polishing, epoxy or oven. Cuts install time on a single drop from 20+ minutes to under 3 minučių.
| Serija | Nutraukimo būdas | IP įvertinimas | Tipiškas naudojimas |
|---|---|---|---|
| IP68 SC/APC Field-Assembly OPT | Mechanical splice, tool-based | IP68 | Emergency repair, single-drop terminations |
| Z-Type PEI Waterproof Connector | Pre-embedded pigtail + Z sleeve | IP68 | Short-length drop cables, fast splice |
Passive coupler used inside outdoor enclosures or between two waterproof pigtails.
| Serija | Body | IP įvertinimas | Tipiškas naudojimas |
|---|---|---|---|
| Mini LC Waterproof Adapter with Copper | Copper sleeve, PA shell | IP67 | In-line splice inside outdoor closures |
The IP code from IEC 60529 defines protection against solids (first digit) ir vandens (second digit). For outdoor fiber, only the water digit varies in practice.
| Įvertinimas | Water Test Condition | Typical Outdoor Use |
|---|---|---|
| IP65 | Low-pressure water jets from all directions | Wall-mount drop terminations under eaves; short-term rain exposure |
| IP67 | Immersion in 1 m of water for 30 minučių | Aerial and pole-mount drops; splash-heavy outdoor cabinets |
| IP68 | Continuous immersion beyond 1 m, condition set by manufacturer | Direct-buried joints; base-station RRU jumpers exposed to standing water and heavy monsoon rain |
Pastaba: IP68 is the only rating that lets the manufacturer define the immersion depth and duration. Always ask for the test report if a project spec calls out “IP68” without a depth value.
Material is selected per model, not per customer request. As a general rule:
| Parametras | Tipinė vertė | komentuoti |
|---|---|---|
| Sealing grade | IP65 / IP67 / IP68 | Selected per series; IP68 depth reported per model on request |
| Pluošto suderinamumas | G.657.A1 / G.657.A2 / G.652.D | G.657.A2 is standard for FTTH drop cables |
| Connector end-face | SC/APC, LC/APC, LC/UPC | APC preferred for FTTH to reduce return-loss impact |
| Įdėjimo praradimas (mated pair) | ≤ 0.3 dB tipiškas | Measured against a reference master jumper |
| Grąžinimo praradimas | ≥ 60 dB (APC) / ≥ 50 dB (UPC) | Per Telcordia GR-326 |
| Darbinė temperatūra | −40°C to +85°C | Per model — some FTTA-grade models qualified to +85°C |
| Cable retention (axial) | ≥ 50 N | Per model; higher values available on FTTA series |
| Mating durability | ≥ 500 ciklai | Per Telcordia GR-326 |
| Būsto medžiaga | PA / PEI / metal-reinforced | Selected per model requirement |
Pastaba: values above are family-typical, not a single-SKU datasheet. Ask us for the specific test report of the model you are quoting; we send it under the model part number.
Fibconet’s parent operation in optical passive components dates back to 1994. The waterproof connector line was industrialized after the FTTx wave in China, and today ships to ISPs, EPC contractors and distributors in more than 40 šalyse.
Antgaliai, sleeves and pigtails are sourced from long-term qualified suppliers. Housings are injection-molded in-house from qualified PA and PEI resins so batch-to-batch dimensional consistency stays under control. G.657.A2 drop-cable pigtails are supplied through our deep bare-fiber inventory and brand distribution partnerships.
Fibconet operates under an ISO 9001 quality management system. Product-level certification — RoHS, REACH, Telcordia GR-326 / GR-3120 test reports, and OEM-specific interface compatibility declarations — is issued per model and per project requirement. Atsiųskite mums savo tikslinę rinką ir modelių sąrašą, ir grąžiname atitinkamą sertifikatų rinkinį su citata.
Minimum order quantity starts at 1,000 pcs per model. Mixed-model orders are accepted above 3,000 pcs total.
Taip. Interface geometry, keying and sealing are built to the original OEM footprint. Field crews can plug our connector into the existing enclosure port without changing the drop cable or the sealing gel. We send a compatibility declaration with the first shipment on request.
IP67 is qualified for 30-minute immersion at 1 m depth. IP68 covers longer or deeper immersion under conditions the manufacturer defines. For aerial and wall-mount drops IP67 is enough; for direct-buried joints or base-station jumpers exposed to standing water, ask for IP68 with a stated depth.
Taip. G.657.A2 is our default for FTTH drop-cable pigtails because it holds transmission at a 7.5 mm lenkimo spindulys. G.652.D and G.657.A1 are available if your project spec requires them.
Taip. Laser marking on the housing, custom color for the boot, and custom label on the bag and carton are available from 1,000 pcs per model.
Stock models ship in 5–7 working days. Custom pigtail length or OEM-labeled orders ship in 15–25 working days after order confirmation, priklausomai nuo kiekio. Confirm the actual date on the pro-forma invoice.
Taip. Insertion loss and return loss are batch-tested and reported per carton. End-face 3D interferometry data and extended qualification reports (druskos purškalas, UV, thermal cycle) are provided on request or where the project tender requires them.
MOQ yra 1,000 pcs per model. Mixed-model orders are accepted from 3,000 pcs total, split across two or three models. This lets distributors trial multiple compatibility options in one shipment.
We ship FCA, FOB, CIF and DDP. DDP is quoted per destination country because of customs, VAT and last-mile handling; send us the delivery address and we return a landed cost quotation.
Family-typical value is ≥ 50 N. Selected FTTA and base-station models are qualified to a higher load. Ask us for the model-specific pull-test report before you tender a project.
Taip. Send the interface drawing, sealing gel spec and target IP grade under NDA. Our engineering team returns a feasibility assessment within 5 working days and a sample within 30 darbo dienos.
Mes atsakysime per 12 Mes atsakysime per, Mes atsakysime per Mes atsakysime per.