Fibconet timmanifattura 12 serje ta 'konnetturi tal-fibra ottika li ma jgħaddix ilma minn barra użati fit-terminazzjonijiet tal-kejbil tal-qatra FTTH, Jumpers tal-istazzjon bażi FTTA, u punti ta' cross-connect ODN ta' barra. Familji ta 'prodotti jkopru IP65, Gradi ta 'siġillar IP67 u IP68, b'housings fil-PA, PEI u metall, magħżula għal kull mudell u għal kull ambjent tal-proġett.
Is-serje kollha huma kompatibbli ma 'interfaces OEM mainstream — Huawei, Zte, Fiberhome, OPT, Fullaxs, ODVA OptiTap, PDLC, NSN u ODC — sabiex l-ekwipaġġi fuq il-post jistgħu jissostitwixxu assemblaġġi tal-legat mingħajr ma jbiddlu l-għeluq jew l-ispeċifikazzjoni tal-kejbil tal-qatra. Id-daqs tipiku tal-ordni jibda minn 1,000 pcs; Tikkettar OEM, tulijiet ta 'pigtail tad-dwana u ippakkjar bl-ingrossa huma appoġġjati għad-distributuri, ISPs u kuntratturi EPC.
Is-sezzjonijiet hawn taħt jelenkaw tagħna 12 serje raggruppati skont l-applikazzjoni, segwit mil-loġika tal-għażla tal-klassifikazzjoni tal-IP, speċifikazzjonijiet tekniċi, kapaċità tal-manifattura, FAQ, u kanal ta 'kwotazzjoni.

Użat biex jissostitwixxi jew jestendu Huawei eżistenti / Zte / Fiberhome / OPT / Skjeramenti Fullaxs. Ġeometrija tal-interface, keying u siġillar isegwu l-footprint OEM oriġinali sabiex l-ebda adapter ma jkun meħtieġ.
| Serje | Interface OEM | Klassifikazzjoni tal-IP | Użu Tipiku |
|---|---|---|---|
| Huawei Kompatibbli Fast-Connect | Huawei | IP68 | Ibdel l-assemblaġġi tal-waqgħa FTTx legacy Huawei |
| Huawei Kompatibbli Mini / Normali | Huawei (Mini + Daqs normali) | IP68 | Siti Huawei ODN ta' ġenerazzjoni mħallta |
| Djar PEI Kompatibbli ZTE | Zte | IP68 | Qtar FTTH standard ZTE fi klima tropikali |
| Kit G657A2 Kompatibbli fiberhome | Fiberhome | IP65 | Fiberhome drop-cable kits mitmuma minn qabel |
| Fiberhome Kompatibbli Pre-konnessi Kit | Fiberhome | IP65 / IP68 | Skjerament rapidu mill-arblu sad-dar |
| Konnettur FTTA Kompatibbli OPT | OPT | IP68 | Jumper tal-istazzjon bażi bejn il-BBU u l-RRU |
| Fullaxs Kompatibbli PA Djar | Fullaxs (LC Duplex) | IP68 | Jumpers ta' barra taċ-ċelluli żgħar u RRU |
Segwi ODVA / Standards tal-industrija MSA aktar milli OEM wieħed. Ippreferut mill-ISPs tal-Amerika ta' Fuq u minn trasportaturi li jmexxu netwerks b'ħafna bejjiegħa.
| Serje | Standard | Klassifikazzjoni tal-IP | Użu Tipiku |
|---|---|---|---|
| Assemblaġġ tal-Kejbil Ottiku PDLC | PDLC (Ibbażat fuq LC) | IP67 | Assemblaġġi ta 'garża ta' barra għal FTTx |
| OptiTap Tip B LC Konnettur | ODVA OptiTap | IP68 | Terminali multi-port FTTH tal-Amerika ta 'Fuq |
Tterminat fuq il-post mingħajr illustrar, epoxy jew forn. Qatgħat tinstalla ħin fuq qatra waħda minn 20+ minuti għal taħt 3 minuti.
| Serje | Metodu ta' Terminazzjoni | Klassifikazzjoni tal-IP | Użu Tipiku |
|---|---|---|---|
| IP68 SC/APC Field-Assembly OPT | Splice mekkaniku, ibbażat fuq għodda | IP68 | Tiswija ta' emerġenza, terminazzjonijiet ta' waqgħa waħda |
| Konnettur li ma jgħaddix ilma minn PEI tat-Tip Z | Pigtail pre-inkorporat + Kmiem Z | IP68 | Kejbils tal-waqgħa ta' tul qasir, splice veloċi |
Coupler passiv użat ġewwa kompartimenti ta 'barra jew bejn żewġ pigtails li ma jgħaddix ilma minnhom.
| Serje | Korp | Klassifikazzjoni tal-IP | Użu Tipiku |
|---|---|---|---|
| Mini LC Waterproof Adapter bir-ram | Copper sleeve, PA shell | IP67 | In-line splice inside outdoor closures |
The IP code from IEC 60529 defines protection against solids (first digit) u ilma (second digit). For outdoor fiber, only the water digit varies in practice.
| Rating | Water Test Condition | Typical Outdoor Use |
|---|---|---|
| IP65 | Low-pressure water jets from all directions | Wall-mount drop terminations under eaves; short-term rain exposure |
| IP67 | Immersion in 1 m of water for 30 minuti | Aerial and pole-mount drops; splash-heavy outdoor cabinets |
| IP68 | Continuous immersion beyond 1 m, condition set by manufacturer | Direct-buried joints; base-station RRU jumpers exposed to standing water and heavy monsoon rain |
Nota: IP68 is the only rating that lets the manufacturer define the immersion depth and duration. Always ask for the test report if a project spec calls out “IP68” without a depth value.
Material is selected per model, not per customer request. As a general rule:
| Parametru | Valur Tipiku | Ikkummenta |
|---|---|---|
| Sealing grade | IP65 / IP67 / IP68 | Selected per series; IP68 depth reported per model on request |
| Kompatibilità tal-fibra | G.657.A1 / G.657.A2 / G.652.D | G.657.A2 is standard for FTTH drop cables |
| Connector end-face | SC/APC, LC / APC, LC/UPC | APC preferred for FTTH to reduce return-loss impact |
| Telf ta' inserzjoni (mated pair) | ≤ 0.3 dB tipiku | Measured against a reference master jumper |
| Telf tar-ritorn | ≥ 60 dB (APC) / ≥ 50 dB (UPC) | Per Telcordia GR-326 |
| Temperatura operattiva | −40°C to +85°C | Per model — some FTTA-grade models qualified to +85°C |
| Cable retention (axial) | ≥ 50 N | Per model; higher values available on FTTA series |
| Durabilità tat-tgħammir | ≥ 500 ċikli | Per Telcordia GR-326 |
| Materjal tad-djar | PA / PEI / metal-reinforced | Selected per model requirement |
Nota: values above are family-typical, not a single-SKU datasheet. Ask us for the specific test report of the model you are quoting; we send it under the model part number.
Fibconet’s parent operation in optical passive components dates back to 1994. The waterproof connector line was industrialized after the FTTx wave in China, and today ships to ISPs, EPC contractors and distributors in more than 40 pajjiżi.
Ferrules, sleeves and pigtails are sourced from long-term qualified suppliers. Housings are injection-molded in-house from qualified PA and PEI resins so batch-to-batch dimensional consistency stays under control. G.657.A2 drop-cable pigtails are supplied through our deep bare-fiber inventory and brand distribution partnerships.
Fibconet operates under an ISO 9001 quality management system. Product-level certification — RoHS, REACH, Telcordia GR-326 / GR-3120 test reports, and OEM-specific interface compatibility declarations — is issued per model and per project requirement. Send us your target market and the model list, and we return the applicable certificate set with the quotation.
Minimum order quantity starts at 1,000 pcs per model. Mixed-model orders are accepted above 3,000 pcs total.
Iva. Ġeometrija tal-interface, keying and sealing are built to the original OEM footprint. Field crews can plug our connector into the existing enclosure port without changing the drop cable or the sealing gel. We send a compatibility declaration with the first shipment on request.
IP67 is qualified for 30-minute immersion at 1 m depth. IP68 covers longer or deeper immersion under conditions the manufacturer defines. For aerial and wall-mount drops IP67 is enough; for direct-buried joints or base-station jumpers exposed to standing water, ask for IP68 with a stated depth.
Iva. G.657.A2 is our default for FTTH drop-cable pigtails because it holds transmission at a 7.5 mm bend radius. G.652.D and G.657.A1 are available if your project spec requires them.
Iva. Laser marking on the housing, custom color for the boot, and custom label on the bag and carton are available from 1,000 pcs per model.
Stock models ship in 5–7 working days. Custom pigtail length or OEM-labeled orders ship in 15–25 working days after order confirmation, skond il-kwantità. Confirm the actual date on the pro-forma invoice.
Iva. Insertion loss and return loss are batch-tested and reported per carton. End-face 3D interferometry data and extended qualification reports (sprej tal-melħ, UV, thermal cycle) are provided on request or where the project tender requires them.
MOQ is 1,000 pcs per model. Mixed-model orders are accepted from 3,000 pcs total, split across two or three models. Dan iħalli lid-distributuri jipprovaw għażliet ta 'kompatibilità multipli f'konsenja waħda.
Aħna nibgħatu FCA, FOB, CIF u DDP. DDP huwa kkwotat għal kull pajjiż ta 'destinazzjoni minħabba d-dwana, VAT u handling tal-aħħar mil; ibgħatilna l-indirizz tal-kunsinna u nirritornaw kwotazzjoni tal-ispiża żbarkata.
Il-valur tipiku tal-familja huwa ≥ 50 N. Mudelli magħżula FTTA u stazzjoni bażi huma kkwalifikati għal tagħbija ogħla. Itlobna għar-rapport tat-test tal-ġibda speċifiku għall-mudell qabel ma tagħmel offerta għal proġett.
Iva. Ibgħat it-tpinġija tal-interface, issiġillar ġel spec u grad IP mira taħt NDA. It-tim tal-inġinerija tagħna jirritorna valutazzjoni tal-fattibilità fi ħdan 5 ġranet tax-xogħol u kampjun fi ħdan 30 ġranet tax-xogħol.
Aħna se nirrispondu fi ħdan 12 sigħat, jekk jogħġbok oqgħod attent għall-email bis-suffiss “@fibconet.com”.
Ukoll, inti tista 'tmur għall- Paġna ta' Kuntatt, li jipprovdi formola aktar dettaljata.