Fibconet tsim 12 ib pawg ntawm cov fiber optic txuas dej tsis nkag sab nraum zoov siv hauv FTTH drop-cable terminations, FTTA base-station jumpers, thiab ODN cross-connect sab nraum zoov. Cov tsev neeg khoom npog IP65, IP67 thiab IP68 sealing grades, nrog lub tsev hauv PA, PEI thiab hlau, xaiv raws qauv thiab ib puag ncig project.

Tag nrho cov series no sib haum nrog cov OEM interface tseem ceeb — Huawei, ZTE, Fiberhome, OPT, Fullaxs, ODVA OptiTap, PDLC, NSN thiab ODC — yog li cov neeg ua haujlwm hauv teb chaws tuaj yeem hloov cov khoom qub yam tsis tas hloov lub thawv lossis drop-cable spec. Qhov loj ntawm kev txiav txim pib ntawm 1,000 pcs; OEM cim npe, ntev pigtail thiab ntim khoom loj txhawb nqa rau cov neeg faib khoom, ISPs thiab EPC contractors.

Cov ntu hauv qab no teev peb cov khoom 12 series faib raws li daim ntawv thov, followed by the IP-rating selection logic, technical specifications, manufacturing capability, FAQ, and a quotation channel.

waterproof connector advantages

12 Waterproof Connector Series We Manufacture

Pawg 1 — Brand-Compatible Outdoor Connectors

Used to replace or extend existing Huawei / ZTE / Fiberhome / OPT / Fullaxs deployments. Interface geometry, keying and sealing follow the original OEM footprint so no adapter is needed.

Koob OEM Interface IP Ntsuas Typical Use
Huawei Compatible Fast-Connect Huawei IP68 Replace Huawei legacy FTTx drop assemblies
Huawei Compatible Mini / Normal Huawei (Mini + Normal size) IP68 Mixed-generation Huawei ODN sites
ZTE Compatible PEI Housing ZTE IP68 ZTE-standard FTTH drops in tropical climate
Fiberhome Compatible G657A2 Kit Fiberhome IP65 Fiberhome drop-cable pre-terminated kits
Fiberhome Compatible Pre-connected Kit Fiberhome IP65 / IP68 Pole-to-home rapid deployment
OPT Compatible FTTA Connector OPT IP68 Base-station jumper between BBU and RRU
Fullaxs Compatible PA Housing Fullaxs (LC duplex) IP68 Outdoor small-cell and RRU jumpers

Pawg 2 — Standard OptiTap / PDLC Connectors

Follow ODVA / MSA industry standards rather than a single OEM. Preferred by North American ISPs and by carriers running multi-vendor networks.

Koob txheej txheem IP Ntsuas Typical Use
PDLC Optical Cable Assembly PDLC (LC based) IP67 Outdoor patch-cord assemblies for FTTx
OptiTap Type B LC Connector ODVA OptiTap IP68 North American FTTH multi-port terminals

Pawg 3 — Field-Assembly Connectors

Terminated on site with no polishing, epoxy or oven. Cuts install time on a single drop from 20+ minutes to under 3 Feeb.

Koob Termination Method IP Ntsuas Typical Use
IP68 SC/APC Field-Assembly OPT Mechanical splice, tool-based IP68 Emergency repair, single-drop terminations
Z-Type PEI Waterproof Connector Pre-embedded pigtail + Z sleeve IP68 Short-length drop cables, fast splice

Pawg 4 — Waterproof Adapter

Passive coupler used inside outdoor enclosures or between two waterproof pigtails.

Koob Body IP Ntsuas Typical Use
Mini LC Waterproof Adapter with Copper Copper sleeve, PA shell IP67 In-line splice hauv qhov kaw sab nraum zoov

Dab tsi yog qhov txuas fiber optic uas tsis muaj dej thiab yuav xaiv hom kom raug

IP65 vs IP67 vs IP68 — Qhov tseeb ntawm txhua qib rau fiber sab nraum zoov

IP code los ntawm IEC 60529 txhais kev tiv thaiv solids (tus lej thawj) thiab dej (tus lej thib ob). Rau fiber sab nraum zoov, tsuas yog tus lej dej xwb uas txawv hauv kev siv.

Qhab nia Kev kuaj dej Kev siv sab nraum zoov feem ntau
IP65 Cov dej qis siab los ntawm txhua qhov kev taw qhia Cov chaw nres dej ntub phab ntsa hauv qab qab tsev; kev ntsib nag luv luv
IP67 Kev tso dej rau hauv 1 m dej rau 30 Feeb Cov dej poob saum huab cua thiab ncej; cov thawv sab nraum zoov uas muaj dej ntws ntau
IP68 Kev tso dej txuas ntxiv sab nraud 1 m, kev teeb tsa los ntawm tus tsim khoom Cov txuas ncaj qha hauv av; cov jumper RRU chaw nres nkoj uas raug dej nres thiab nag hnyav los nag

Ntawv Ceeb Toom: IP68 yog qhov ntsuas nkaus xwb uas tso cai rau tus tsim khoom txhais qhov tob thiab sijhawm nkag mus rau hauv dej. Txhua lub sijhawm thov daim ntawv qhia kev kuaj yog tias ib qho kev piav qhia hauv qhov project hais txog nws “IP68” tsis tas yuav qhia qhov tob nqi.

Yuav ua li cas thiaj phim qhov txuas rau koj qhov xwm txheej hauv tebchaws

  • Koj tab tom hloov cov khoom siv qub ntawm ib lub tuam txhab tshwj xeeb → xaiv cov series uas haum rau hom (Huawei / ZTE / Fiberhome / OPT / Fullaxs) kom lub thawv thiab lub cable poob tsis hloov.
  • Koj khiav North American multi-vendor FTTH network → ua qauv rau OptiTap Type B; ODVA MSA xyuas kom muaj kev hloov pauv thoob plaws cov neeg muab khoom.
  • Koj xav tau kev xaus sai hauv teb chaws tsis tas yuav txhuam cov cuab yeej → xaiv field-assembly series; ib pab neeg tau kawm tuaj yeem nruab connector hauv kwv yees li 3 Feeb.
  • Koj deploy FTTA ntawm BBU thiab RRU → siv IP68 uas haum OPT lossis IP68 uas haum Fullaxs nrog LC duplex geometry.
  • Koj yuav tsum muaj ib qho coupler nruab nrab hauv kab hauv ib lub thawv sab nraum zoov → siv Mini LC waterproof adapter, tsis yog lwm qhov txuas.

Cov khoom siv hauv tsev — PA, PEI lossis hlau

Cov khoom siv xaiv raws qauv, tsis yog raws li tus neeg siv khoom thov. Raws li ib qho kev cai dav dav:

  • PA (polyamide): tsev sab nraum zoov qauv; sib npaug nqi, tiv thaiv UV thiab muaj zog cuam tshuam.
  • PEI (polyetherimide): tiv taus kub thiab tshuaj lom ntau dua; siv rau qhov chaw raug tshav ntuj lossis ntsev tsuag hnyav.
  • Kev txhawb hlau: siv rau qee yam FTTA thiab base-station qauv uas muaj kev nias tshuab yog qhov yuav tsum tau ua.

Technical Specifications

parameter Raug tus nqi raug tus mob no Saib
Sealing grade IP65 / IP67 / IP68 Xaiv rau txhua series; IP68 qhov tob qhia rau txhua qauv yog xav tau
Fiber compatibility G.657.A1 / G.657.A2 / G.652.D G.657.A2 yog qauv rau FTTH hlua poob
Connector kawg SC/APC, LC/APC, LC/UPC APC nyiam rau FTTH kom txo kev cuam tshuam rov qab
insertion poob (khub txuas) ≤ 0.3 dB feem ntau Ntsuas piv rau ib qho piv txwv master jumper
Rov qab los ≥ 60 dB (APC) / ≥ 50 dB (UPC) Raws li Telcordia GR-326
Kev khiav hauj lwm kub −40°C txog +85°C Per model — some FTTA-grade models qualified to +85°C
Cable retention (axial) ≥ 50 N Txhua qauv; higher values available on FTTA series
Mating durability ≥ 500 cycles Raws li Telcordia GR-326
Vaj tse PA / PEI / metal-reinforced Selected per model requirement

Ntawv Ceeb Toom: values above are family-typical, tsis yog ib daim datasheet SKU xwb. Thov nug peb txog daim ntawv kuaj tshwj xeeb ntawm tus qauv uas koj tau hais txog; peb xa nrog tus qauv part number.

Kev Tsim Khoom thiab Kev Tswj Zoo

Production History

Fibconet txoj kev ua haujlwm hauv cov khoom siv optical passive pib txij thaum pib 1994. The waterproof connector line was industrialized after the FTTx wave in China, and today ships to ISPs, EPC contractors and distributors in more than 40 lub teb chaws.

Raw Material and Supply Chain

Ferrules, sleeves and pigtails are sourced from long-term qualified suppliers. Housings are injection-molded in-house from qualified PA and PEI resins so batch-to-batch dimensional consistency stays under control. G.657.A2 drop-cable pigtails are supplied through our deep bare-fiber inventory and brand distribution partnerships.

In-line and Outgoing Quality Control

  • End-face 3D interferometry per Telcordia GR-326 on 100% of factory-terminated pigtails.
  • Insertion loss and return loss test with reference master jumper, batch-recorded.
  • Sealing test on 100% of housings before packaging; extended immersion, ntsev, UV and thermal-cycle testing performed per model qualification and per project requirement.
  • Serialized test data available on request for tender projects.

Kev pov thawj thiab Kev Ua Raws Cai

Fibconet operates under an ISO 9001 quality management system. Product-level certification — RoHS, REACH, Telcordia GR-326 / GR-3120 test reports, and OEM-specific interface compatibility declarations — is issued per model and per project requirement. Send us your target market and the model list, and we return the applicable certificate set with the quotation.

ntim, OEM and Custom Labeling

  • Pob khoom qauv: individual anti-static bag → inner carton (50 Lossis 100 pcs) → export master carton with pallet marking.
  • OEM cim npe: koj lub logo thiab tus lej khoom ntawm lub cev txuas, ntawm lub hnab, thiab ntawm lub thawv.
  • Ntev pigtail ua raws li kev cai: ntev twg los ntawm 0.5 m mus rau 300 m, txiav thiab xaus rau koj daim ntawv khoom siv.
  • Kitting: txuas nrog + poob cable + gel + cuab yeej ntim ua ib pob khoom nruab rau ISPs thiab EPC pab pawg.

Tus naj npawb txiav txim tsawg kawg pib ntawm 1,000 pcs ib qauv. Cov kev txiav txim sib xyaw tau txais saum toj no 3,000 pcs tag nrho.

Cov Lus Nug Feem Ntau

Q1. Koj cov txuas dej puas tiag tiag hloov tau nrog Huawei qub / ZTE / Fiberhome / OPT / Fullaxs kho vajtse?

Muaj. Interface geometry, keying thiab sealing yog tsim rau OEM footprint qub. Cov neeg ua haujlwm hauv teb chaws tuaj yeem txuas peb connector rau hauv qhov chaw kaw uas twb muaj lawm tsis tas hloov lub cable poob lossis gel kaw. Peb xa ib daim ntawv qhia kev sib haum xeeb nrog thawj qhov xa khoom thaum thov.

Q2. Dab tsi yog qhov txawv ntawm IP67 thiab IP68 rau ib qho txuas fiber, xyaum ua tej yam?

IP67 tau tsim nyog rau 30-feeb immersion ntawm 1 m tob. IP68 tso cai rau kev tso dej ntev dua lossis tob dua raws li cov xwm txheej uas tus tsim khoom tau teeb tsa. Rau kev tso pa saum huab cua thiab phab ntsa, IP67 txaus; Rau cov txuas ncaj qha hauv av lossis base-station jumpers uas ntsib dej nres, thov IP68 nrog qhov tob teev tseg.

Q3. Koj puas tuaj yeem xaus pigtail nrog G.657.A2 fiber?

Muaj. G.657.A2 yog peb qhov default rau FTTH drop-cable pigtails vim nws tswj kev xa xov ntawm a 7.5 mm bend radius. G.652.D thiab G.657.A1 muaj yog tias koj cov lus qhia haujlwm xav tau.

Q4. Koj puas txhawb OEM luam ntawv ntawm lub cev txuas?

Muaj. Laser cim ntawm lub thawv, Xim kho rau lub thawv, Thiab cov cim tshwj xeeb ntawm hnab thiab thawv muaj los ntawm 1,000 pcs ib qauv.

Q5. Lub sijhawm ua haujlwm feem ntau?

Cov qauv stock xa tawm hauv 5–7 hnub ua haujlwm. Ntev pigtail tsim tshwj xeeb lossis kev txiav txim OEM cim xa hauv 15–25 hnub ua haujlwm tom qab lees paub kev txiav txim, Raws li qhov ntau. Xyuas hnub tiag tiag ntawm daim nqi pro-forma.

Q6. Do you provide test reports with each shipment?

Muaj. Insertion loss and return loss are batch-tested and reported per carton. End-face 3D interferometry data and extended qualification reports (ntsev, UV, thermal cycle) are provided on request or where the project tender requires them.

Q7. Can I mix models in a single order to reach MOQ?

MOQ is 1,000 pcs ib qauv. Mixed-model orders are accepted from 3,000 pcs tag nrho, split across two or three models. This lets distributors trial multiple compatibility options in one shipment.

Q8. Do you ship DDP to Europe, North America and Latin America?

We ship FCA, FOB, CIF and DDP. DDP is quoted per destination country because of customs, VAT and last-mile handling; send us the delivery address and we return a landed cost quotation.

Q9. What is the axial cable retention of your outdoor connectors?

Tus nqi tsev neeg yog ≥ 50 N. Qee hom FTTA thiab base-station tau tsim nyog rau kev thauj khoom siab dua. Thov nug peb txog daim ntawv qhia pull-test tshwj xeeb ntawm qauv ua ntej koj muab project.

Q10. Koj puas tuaj yeem txhawb NPI (kev qhia khoom tshiab) rau interface uas peb tsim tshwj xeeb?

Muaj. Xa daim duab interface, sealing gel spec thiab hom IP qib raws NDA. Peb pab neeg engineering xa rov qab kev ntsuam xyuas ua tau hauv 5 hnub ua haujlwm thiab qauv hauv ntawd 30 hnub ua haujlwm.

Tau ib ceev tsocai

Peb yuav teb tsis pub dhau 12 Teev, Thov xyuam xim rau tus email nrog lub suffix "@fibconet.com".

Kuj, koj yuav mus rau qhov Hu rau Page 10, uas muab ib daim ntawv ntxiv.