Fibconet tsim 12 ib pawg ntawm cov fiber optic txuas dej tsis nkag sab nraum zoov siv hauv FTTH drop-cable terminations, FTTA base-station jumpers, thiab ODN cross-connect sab nraum zoov. Cov tsev neeg khoom npog IP65, IP67 thiab IP68 sealing grades, nrog lub tsev hauv PA, PEI thiab hlau, xaiv raws qauv thiab ib puag ncig project.
Tag nrho cov series no sib haum nrog cov OEM interface tseem ceeb — Huawei, ZTE, Fiberhome, OPT, Fullaxs, ODVA OptiTap, PDLC, NSN thiab ODC — yog li cov neeg ua haujlwm hauv teb chaws tuaj yeem hloov cov khoom qub yam tsis tas hloov lub thawv lossis drop-cable spec. Qhov loj ntawm kev txiav txim pib ntawm 1,000 pcs; OEM cim npe, ntev pigtail thiab ntim khoom loj txhawb nqa rau cov neeg faib khoom, ISPs thiab EPC contractors.
Cov ntu hauv qab no teev peb cov khoom 12 series faib raws li daim ntawv thov, followed by the IP-rating selection logic, technical specifications, manufacturing capability, FAQ, and a quotation channel.

Used to replace or extend existing Huawei / ZTE / Fiberhome / OPT / Fullaxs deployments. Interface geometry, keying and sealing follow the original OEM footprint so no adapter is needed.
| Koob | OEM Interface | IP Ntsuas | Typical Use |
|---|---|---|---|
| Huawei Compatible Fast-Connect | Huawei | IP68 | Replace Huawei legacy FTTx drop assemblies |
| Huawei Compatible Mini / Normal | Huawei (Mini + Normal size) | IP68 | Mixed-generation Huawei ODN sites |
| ZTE Compatible PEI Housing | ZTE | IP68 | ZTE-standard FTTH drops in tropical climate |
| Fiberhome Compatible G657A2 Kit | Fiberhome | IP65 | Fiberhome drop-cable pre-terminated kits |
| Fiberhome Compatible Pre-connected Kit | Fiberhome | IP65 / IP68 | Pole-to-home rapid deployment |
| OPT Compatible FTTA Connector | OPT | IP68 | Base-station jumper between BBU and RRU |
| Fullaxs Compatible PA Housing | Fullaxs (LC duplex) | IP68 | Outdoor small-cell and RRU jumpers |
Follow ODVA / MSA industry standards rather than a single OEM. Preferred by North American ISPs and by carriers running multi-vendor networks.
| Koob | txheej txheem | IP Ntsuas | Typical Use |
|---|---|---|---|
| PDLC Optical Cable Assembly | PDLC (LC based) | IP67 | Outdoor patch-cord assemblies for FTTx |
| OptiTap Type B LC Connector | ODVA OptiTap | IP68 | North American FTTH multi-port terminals |
Terminated on site with no polishing, epoxy or oven. Cuts install time on a single drop from 20+ minutes to under 3 Feeb.
| Koob | Termination Method | IP Ntsuas | Typical Use |
|---|---|---|---|
| IP68 SC/APC Field-Assembly OPT | Mechanical splice, tool-based | IP68 | Emergency repair, single-drop terminations |
| Z-Type PEI Waterproof Connector | Pre-embedded pigtail + Z sleeve | IP68 | Short-length drop cables, fast splice |
Passive coupler used inside outdoor enclosures or between two waterproof pigtails.
| Koob | Body | IP Ntsuas | Typical Use |
|---|---|---|---|
| Mini LC Waterproof Adapter with Copper | Copper sleeve, PA shell | IP67 | In-line splice hauv qhov kaw sab nraum zoov |
IP code los ntawm IEC 60529 txhais kev tiv thaiv solids (tus lej thawj) thiab dej (tus lej thib ob). Rau fiber sab nraum zoov, tsuas yog tus lej dej xwb uas txawv hauv kev siv.
| Qhab nia | Kev kuaj dej | Kev siv sab nraum zoov feem ntau |
|---|---|---|
| IP65 | Cov dej qis siab los ntawm txhua qhov kev taw qhia | Cov chaw nres dej ntub phab ntsa hauv qab qab tsev; kev ntsib nag luv luv |
| IP67 | Kev tso dej rau hauv 1 m dej rau 30 Feeb | Cov dej poob saum huab cua thiab ncej; cov thawv sab nraum zoov uas muaj dej ntws ntau |
| IP68 | Kev tso dej txuas ntxiv sab nraud 1 m, kev teeb tsa los ntawm tus tsim khoom | Cov txuas ncaj qha hauv av; cov jumper RRU chaw nres nkoj uas raug dej nres thiab nag hnyav los nag |
Ntawv Ceeb Toom: IP68 yog qhov ntsuas nkaus xwb uas tso cai rau tus tsim khoom txhais qhov tob thiab sijhawm nkag mus rau hauv dej. Txhua lub sijhawm thov daim ntawv qhia kev kuaj yog tias ib qho kev piav qhia hauv qhov project hais txog nws “IP68” tsis tas yuav qhia qhov tob nqi.
Cov khoom siv xaiv raws qauv, tsis yog raws li tus neeg siv khoom thov. Raws li ib qho kev cai dav dav:
| parameter | Raug tus nqi raug tus mob no | Saib |
|---|---|---|
| Sealing grade | IP65 / IP67 / IP68 | Xaiv rau txhua series; IP68 qhov tob qhia rau txhua qauv yog xav tau |
| Fiber compatibility | G.657.A1 / G.657.A2 / G.652.D | G.657.A2 yog qauv rau FTTH hlua poob |
| Connector kawg | SC/APC, LC/APC, LC/UPC | APC nyiam rau FTTH kom txo kev cuam tshuam rov qab |
| insertion poob (khub txuas) | ≤ 0.3 dB feem ntau | Ntsuas piv rau ib qho piv txwv master jumper |
| Rov qab los | ≥ 60 dB (APC) / ≥ 50 dB (UPC) | Raws li Telcordia GR-326 |
| Kev khiav hauj lwm kub | −40°C txog +85°C | Per model — some FTTA-grade models qualified to +85°C |
| Cable retention (axial) | ≥ 50 N | Txhua qauv; higher values available on FTTA series |
| Mating durability | ≥ 500 cycles | Raws li Telcordia GR-326 |
| Vaj tse | PA / PEI / metal-reinforced | Selected per model requirement |
Ntawv Ceeb Toom: values above are family-typical, tsis yog ib daim datasheet SKU xwb. Thov nug peb txog daim ntawv kuaj tshwj xeeb ntawm tus qauv uas koj tau hais txog; peb xa nrog tus qauv part number.
Fibconet txoj kev ua haujlwm hauv cov khoom siv optical passive pib txij thaum pib 1994. The waterproof connector line was industrialized after the FTTx wave in China, and today ships to ISPs, EPC contractors and distributors in more than 40 lub teb chaws.
Ferrules, sleeves and pigtails are sourced from long-term qualified suppliers. Housings are injection-molded in-house from qualified PA and PEI resins so batch-to-batch dimensional consistency stays under control. G.657.A2 drop-cable pigtails are supplied through our deep bare-fiber inventory and brand distribution partnerships.
Fibconet operates under an ISO 9001 quality management system. Product-level certification — RoHS, REACH, Telcordia GR-326 / GR-3120 test reports, and OEM-specific interface compatibility declarations — is issued per model and per project requirement. Send us your target market and the model list, and we return the applicable certificate set with the quotation.
Tus naj npawb txiav txim tsawg kawg pib ntawm 1,000 pcs ib qauv. Cov kev txiav txim sib xyaw tau txais saum toj no 3,000 pcs tag nrho.
Muaj. Interface geometry, keying thiab sealing yog tsim rau OEM footprint qub. Cov neeg ua haujlwm hauv teb chaws tuaj yeem txuas peb connector rau hauv qhov chaw kaw uas twb muaj lawm tsis tas hloov lub cable poob lossis gel kaw. Peb xa ib daim ntawv qhia kev sib haum xeeb nrog thawj qhov xa khoom thaum thov.
IP67 tau tsim nyog rau 30-feeb immersion ntawm 1 m tob. IP68 tso cai rau kev tso dej ntev dua lossis tob dua raws li cov xwm txheej uas tus tsim khoom tau teeb tsa. Rau kev tso pa saum huab cua thiab phab ntsa, IP67 txaus; Rau cov txuas ncaj qha hauv av lossis base-station jumpers uas ntsib dej nres, thov IP68 nrog qhov tob teev tseg.
Muaj. G.657.A2 yog peb qhov default rau FTTH drop-cable pigtails vim nws tswj kev xa xov ntawm a 7.5 mm bend radius. G.652.D thiab G.657.A1 muaj yog tias koj cov lus qhia haujlwm xav tau.
Muaj. Laser cim ntawm lub thawv, Xim kho rau lub thawv, Thiab cov cim tshwj xeeb ntawm hnab thiab thawv muaj los ntawm 1,000 pcs ib qauv.
Cov qauv stock xa tawm hauv 5–7 hnub ua haujlwm. Ntev pigtail tsim tshwj xeeb lossis kev txiav txim OEM cim xa hauv 15–25 hnub ua haujlwm tom qab lees paub kev txiav txim, Raws li qhov ntau. Xyuas hnub tiag tiag ntawm daim nqi pro-forma.
Muaj. Insertion loss and return loss are batch-tested and reported per carton. End-face 3D interferometry data and extended qualification reports (ntsev, UV, thermal cycle) are provided on request or where the project tender requires them.
MOQ is 1,000 pcs ib qauv. Mixed-model orders are accepted from 3,000 pcs tag nrho, split across two or three models. This lets distributors trial multiple compatibility options in one shipment.
We ship FCA, FOB, CIF and DDP. DDP is quoted per destination country because of customs, VAT and last-mile handling; send us the delivery address and we return a landed cost quotation.
Tus nqi tsev neeg yog ≥ 50 N. Qee hom FTTA thiab base-station tau tsim nyog rau kev thauj khoom siab dua. Thov nug peb txog daim ntawv qhia pull-test tshwj xeeb ntawm qauv ua ntej koj muab project.
Muaj. Xa daim duab interface, sealing gel spec thiab hom IP qib raws NDA. Peb pab neeg engineering xa rov qab kev ntsuam xyuas ua tau hauv 5 hnub ua haujlwm thiab qauv hauv ntawd 30 hnub ua haujlwm.
Peb yuav teb tsis pub dhau 12 Teev, Thov xyuam xim rau tus email nrog lub suffix "@fibconet.com".
Kuj, koj yuav mus rau qhov Hu rau Page 10, uas muab ib daim ntawv ntxiv.