FIBCONET manufactures fiber optic ڳنڍيندڙ ۽ اڊاپٽر covering the full range of formats used in FTTH access, data-centre cabinets, telecom central offices and outdoor deployments — from standard SC / ايل سي / ايف سي / ايس ٽي / ايم پي او / ايم ٽي آر جي / E2000 to IP67 / IP68 پنروڪ outdoor-rated connectors and field-assembly (fast) connectors for on-site termination.

Every connector and adapter ships after 100% factory inspection — end-face 3D interferometer for MPO, insertion loss and return loss measurement on all fiber types, and mating durability verification against IEC 61754 ۽ Telcordia GR-326-CORE (ڪلاس آر) طريقو. Ferrules are Sanhuan (Sumitomo on request), and connector bodies come in standard telecom grade through outdoor waterproof PEI / PDLC housings.
An adapter (also called coupler or mating sleeve) is the passive component that joins two connectors face-to-face inside an ODF panel, patch panel, wall plate or termination box. It aligns the two ferrules within tight concentricity tolerance so the light passes across the junction with minimum loss and reflection.
| Connector Format | Sleeve Material | عام داخل ٿيڻ جو نقصان | واپسي جو نقصان |
|---|---|---|---|
| ايس سي | سيرامڪ (zirconia) | ≤ 0.2 ڊي بي | يو پي سي ≥ 50 ڊي بي; APC ≥ 55 ڊي بي |
| ايل سي | سيرامڪ (zirconia) | ≤ 0.2 ڊي بي | يو پي سي ≥ 50 ڊي بي; APC ≥ 55 ڊي بي |
| ايف سي | سيرامڪ (zirconia) | ≤ 0.2 ڊي بي | يو پي سي ≥ 50 ڊي بي; APC ≥ 55 ڊي بي |
| ايس ٽي | سيرامڪ (zirconia) | ≤ 0.2 ڊي بي | يو پي سي ≥ 50 ڊي بي |
| ايم پي او / ايم ٽي پي | Precision-molded polymer with pin alignment | ≤ 0.35 dB average (گھٽ نقصان) | ≥ 55 ڊي بي (اي پي سي) |
| E2000, ايم ٽي آر جي, ايم يو | سيرامڪ | ≤ 0.2 ڊي بي | يو پي سي ≥ 50 ڊي بي; APC ≥ 55 ڊي بي |
۾ موجود simplex, duplex and quad ترتيبون, with mounting flanges for standard ODF drawer, wall plate, patch panel and custom panel cutouts. Colour coding follows the industry convention — blue for UPC, green for APC, aqua for OM3/OM4, lime green for OM5, beige for OM1/OM2 — so any technician can identify the format at a glance.

Our connector line splits into three families depending on how the fiber is terminated:
| قسم | ختم ڪرڻ جو طريقو | لاء بهترين |
|---|---|---|
| Factory-Terminated Connector (polished on our patch cord line) |
Fusion-splice, epoxy + polish in factory | پيچ تارون, سور, ODF pre-terminated cabling — highest and most consistent optical performance |
| Field-Assembly (Fast) ڳنڍيندڙ | Mechanical splice on-site, no fusion splicer required | FTTH field deployment, drop-cable termination, emergency repair — see our dedicated Fast Connector category for the full line |
| پنروڪ / Outdoor Connector (PDLC, خوش, IP67 / IP68) |
Pre-terminated cable assembly with sealed housing | Base-station RRU, outdoor equipment, telecom compatibility (HW / ZTE / Ericsson), harsh-environment interconnect |
For pre-terminated cable assemblies, connectors are integrated onto FIBCONET patch cords in-house — giving you traceable ferrule origin, insertion loss test report per core, and consistent batch performance. For field-assembly connectors, our dedicated Fast Connector category covers threaded self-locking, alligator- وات, drawer-type, CCTC single-ceramic, three-ring double-ceramic and other field-installable formats used in FTTH last-mile projects.
All three describe how the ferrule end-face is polished, and each gives a different return loss value.
| پولش جو قسم | واپسي جو نقصان | Where to Use |
|---|---|---|
| پي سي (جسماني رابطو) | ≥ 40 ڊي بي | Legacy telecom, low-cost general use — largely superseded by UPC |
| يو پي سي (الٽرا جسماني رابطو) | ≥ 50 ڊي بي | Data centres, انٽرپرائز نيٽ ورڪ, most FTTH indoor cabling — the mainstream default |
| اي پي سي (زاويه جسماني رابطو, 8° polish) | ≥ 55 ڊي بي | مون / FTTH ٻاهران پلانٽ, CATV آر ايف-اوور گلاس, DWDM — anywhere high return loss is critical to prevent signal reflection |
انگن جو قاعدو: use APC (green connector) for anything carrying an RF-modulated signal or a PON drop; يو پي سي (blue connector) for standard data traffic. Never mate UPC to APC — the polish angle mismatch will introduce significant loss and can damage the ferrules.
| پيرا ميٽر | قدر |
|---|---|
| تعميل / test standards | IEC 61754, Telcordia GR-326-CORE Class R, IEC 61300 ڪلاس يو |
| داخل ٿيڻ جو نقصان (عام) | ≤ 0.2 dB standard connector; ≤ 0.35 dB low-loss MPO; down to 0.15 dB with imported ferrules |
| واپسي جو نقصان | PC ≥ 40 ڊي بي, يو پي سي ≥ 50 ڊي بي, APC ≥ 55 ڊي بي |
| ملائڻ جي استحڪام | ايس سي / ايل سي / FC ≥ 1,000 سائيڪلن; MPO ≥ 500 سائيڪلن |
| آپريٽنگ درجه حرارت | -40 کان +85 °C for outdoor / پنروڪ; −20 to +60 °C for indoor standard |
| Waterproof rating (outdoor connectors) | IP67 / IP68 |
| Ferrule materials | Zirconia ceramic (default Sanhuan; Sumitomo on request); precision-molded polymer with pin alignment (ايم پي او) |
| Housing materials | Standard plastic (اندر); PEI or PDLC engineering plastic (ٻاهران / پنروڪ) |


Standard SC / ايل سي / ايف سي / ST adapters and connectors ship from stock without a strict MOQ — sample and trial orders are welcome. MPO connectors typically start at 100 يونٽ. Waterproof and telecom-compatible connectors (اسان جو ٽي ان ون آئوٽ ڊور آپٽيڪل فائبر ڪنيڪشن ڪنورٽر وجود ۾ آيو / ZTE / Ericsson) are quoted per project depending on housing spec.
اي ڳنڍيندڙ is the plug at the end of a fiber cable — it holds the ferrule and terminates the fiber. هڪ اڊاپٽر (also called coupler or mating sleeve) is the passive junction that joins two connectors face-to-face, aligning their ferrules for low-loss signal transfer. Every ODF, patch panel or wall plate uses adapters to receive incoming connectors from patch cords or pigtails.
استعمال ڪريو اي پي سي (green connector, 8° angled polish) for any PON / FTTH outside plant link, CATV آر ايف-اوور گلاس, and DWDM — anywhere reflected light could interfere with the signal. استعمال ڪريو يو پي سي (blue connector) for standard data traffic in data centres, enterprise networks and most indoor cabling. Never mate UPC to APC — the angle mismatch causes major loss and can damage the ferrules.
ها. اسان ٺاهيندا آهيون IP67 and IP68 waterproof connectors in PDLC and PEI housings, Huawei سان گڏ مطابقت, ZTE, Ericsson and other major telecom equipment vendors. Please specify the target equipment model at RFQ stage so we can confirm the correct housing and interface spec.
ها. Every shipment includes 100% factory test results (end-face, داخل ٿيڻ جو نقصان, واپسي جو نقصان). Electronic test reports in FLUKE or EXFO format are available on request — useful for project acceptance and customer audit.
ها, we manufacture a full line of field-assembly connectors — threaded self-locking, alligator- وات, drawer-type, CCTC single-ceramic, three-ring double-ceramic and more. See our dedicated Fast Connector category for the full range and specifications.
اسان اندر جواب ڏينداسين 12 ڪلاڪ, مهرباني ڪري لاتعداد سان اي ميل ڏانهن ڌيان ڏيو "@fibconet.com".
پڻ, توهان ڏانهن وڃي سگهو ٿا رابطو صفحو, جيڪو وڌيڪ تفصيلي فارم مهيا ڪري ٿو.