Tarjimani tahrirlash
Qidirmoq

Optik tolali kabel

Fiber Optic Cable Manufacturer — GYTS, GYTA, ADSS, ASU, Qoldirish, Air-Blown Micro & Submarine Cable

FIBCONET has manufactured fiber optic cable in China for 12 yillar, running dedicated automated lines for stranded loose-tube, central-tube, o'z-o'zini qo'llab-quvvatlash, air-blown micro and submarine cable series.

Combined output on our mainstream armored lines (GYTS / GYTA) reaches tens of millions of fiber-kilometers per year, with stock inventory maintained across 4–288-core standard configurations.

optik tolali kabel tuzilishi

Every drum ships after 100% factory testing — attenuation, kuchlanish, water penetration and end-of-drum OTDR trace — against IEC 60794 series and other applicable standards. Our submarine cable also complies with GB/T 18480, ITU-T G.976 and GJB 4489 military-grade specifications.

Below are the twelve cable series currently shipping to telecom operators, engineering contractors, power utilities and FTTH integrators across Southeast Asia, Yaqin Sharq, Latin America and Europe. Each product page carries fiber count options, connector-ready pre-termination, and full mechanical / environmental specifications.

Fiber Optic Cable Series We Manufacture

Kabel turi Model Joylashtirish Max Fiber Count Key Highlight
Stranded Loose Tube, Steel-Tape Armored GYTS Kanal, havo 288 tolalar Long-term tensile 600 N; crush 300 N/100 mm; 20-year jacket life
Stranded Loose Tube, Aluminum-Tape Armored GYTA Kanal, havo (PE conduit for direct burial) 288 tolalar Anti-rodent, moisture-blocking, EMI-shielding; UV-additive option extends life +5 yillar
Central Loose Tube, Non-Metallic GYXTY / GYFXY (FRP-reinforced) Antenna, kanal, lightning-prone regions 24 tolalar Yengil, all-dielectric; jacket down to 1.1 mm; 10,000 km / month output
To'liq dielektrik o'zini o'zi qo'llab-quvvatlaydi (ADSS), Single-Jacket ADSS Single-Jacket Antenna, power-line corridors, gacha cho'ziladi 300 m 144 tolalar Aramid strength member; PE jacket 1.8 mm ± 0.1 mm; 25–40% lower cost than double-jacket
ADSS, Double-Jacket ADSS Double-Jacket Aerial in coastal salt-fog, muzlash, long-span installations 288 (qadar 576 custom) 10–15 years extended service life vs single-jacket; 720 h tuz-purkagich sinovdan o'tkazildi; UV per GB/T 18899-2023
Aerial Self-Supporting (ASU) ASU / GYFXY-lightweight Short-span aerial & duct dual use, qadar 120 m Span 24 tolalar 3,000 h UV without cracking; 15-year warranty with 1:1 defect replacement; lower cost than ADSS
Figure-8 Central-Tube GYXTC8S Aerial with integral messenger, qadar 100 m Span 96 tolalar 7×1.2 galvanized steel strand messenger, 5 kN tensile; 30-year UV per IEC 60794-1
Air-Blown Micro Cable Grija / GCYFXY Microduct systems 144 tolalar (stranded); 24 tolalar (central-tube) Outer diameter from 1.8 mm; grooved jacket for extended blowing distance; HDPE or LSZH
FTTH Drop Cable, Bow-Type Self-Supporting GJYXCH FTTH outdoor drop with steel or FRP messenger 1–4 fibers G.657.A2 default; steel-wire or non-metallic (FRP) messenger; LSZH / PE / PVC ko'ylagi
FTTH Drop Cable, Indoor Bow-Type GJXH FTTH indoor drop, ko'taruvchi 1–4 fibers LSZH jacket standard; G.657.A2 bend-insensitive fiber
Yopiq taqsimlash kabeli GJFJV / tight-buffer Building risers, indoor cabling, patch cord raw stock 2–24 fibers 5 production lines × 180 km/day; long-term tensile 200 N (2.0 mm); operating −20 to +70 °C
Submarine Cable GYTA33 & deep-water armored Sohil, island interconnect, offshore platforms, deep-water up to 8,000 m 288 tolalar 100 Gb/s unrepeated span up to 500 km; long-term tensile 4 kN, short-term 10 kN; 25-year design life; meets GB/T 18480, IEC 60794, ITU-T G.976 and GJB 4489

OPGW (Optik tuproqli sim) and photoelectric composite cable are also part of our line for power-utility deployments — see the OPGW product page for structural options and short-circuit current ratings.

fiber optic cable series

How to Choose the Right Fiber Optic Cable

Three questions determine the right cable for a project: where it’s installed, how many fibers it carries, va what mechanical / environmental loads it faces.

1. Match the Cable to the Deployment Environment

Deployment Environment Tavsiya etilgan seriya Nima uchun
Kanal / o'tkazgich (standard telecom trunk) GYTS or GYTA Zirhli, high tensile, 20-Yilning yashash muddati
Antenna, lightning-prone region GYFTY / GYXTY (non-metallic) or ADSS All-dielectric prevents lightning damage
Aerial along power lines (spans > 100 m) ADSS Single-Jacket (temperate) or Double-Jacket (qirg'oq / muzlash) Self-supporting up to 300 m; aramid-yarn strength
Direct burial GYTA53 (double-jacket + steel-tape armor) or GYTA + PE conduit Rodent, crush and moisture protection
Microduct (existing or new) Air-Blown Micro Cable (Grija / GCYFXY) 1.8 mm minimum diameter, groove jacket for blow distance
Short-span aerial + duct dual-use ASU Cheaper than ADSS, higher tensile than standard drop cable
Aerial with integral messenger, mid-span Figure-8 GYXTC8S Built-in steel messenger, 5 kN tensile, 100 m Span
FTTH outdoor drop GJYXCH bow-type self-supporting Steel or FRP messenger; G.657.A2 bend-insensitive fiber
FTTH indoor drop / ko'taruvchi GJXH indoor bow-type LSZH jacket for building fire code
Sohil, island interconnect, offshor Submarine cable (GYTA33 series) HDPE jacket, galvanized or Zn-Al armored steel wires
Power utility ground wire OPGW Composite power ground + optik kabel

2. Calculate the Fiber Count You Need

A working formula: total equipment ports × 2, plus a 10–20% spare buffer. For serial-multiplexed devices the count can be lower. Standard fiber counts we stock: 2, 4, 6, 8, 12, 24, 48, 96, 144, 288. Non-standard counts including 576-core (ADSS ikki qavatli ko'ylagi) so'rov bo'yicha mavjud.

3. Match Jacket and Armor to the Load Profile

  • Standard PE — general outdoor, 20-Yilning yashash muddati
  • UV-additive PE — extends outdoor life by ~5 years for high-solar regions
  • DA (kuzatuvga qarshi) PE — for ADSS installed near high-voltage lines to resist electrical corrosion
  • LSZH — low smoke zero halogen for tunnels, metrolar, data centres and indoor riser
  • HDPE — submarine, high-crush and pressure environments
  • Steel-tape armor (GYTS) — rodent protection, namlik, EMI shielding
  • Aluminum-tape armor (GYTA) — equivalent protection, lower weight, better in some corrosive environments
  • 316L stainless steel armor — coastal / marine upgrade for figure-8 messenger; Zn-Al plated for corrosion

GYTS vs GYTA vs ADSS — Quick Comparison for Telecom Trunk Cabling

GYTS GYTA ADSS
Qurol Corrugated steel tape Corrugated aluminum tape None (all-dielectric)
Strength member Chelik sim (FRP for lightning zones) Chelik sim Aramid ip
Aerial span limit ~80 m ~80 m Qadar 300 m
Direct burial PE conduit recommended PE conduit mandatory Qo'llanilmaydigan, qo'llab bo'lmaydigan
uchun eng yaxshisi Standard duct / havo, high-rodent risk Same as GYTS, lower weight Long-span aerial along power poles

Technical Specifications Across Trunk Cable Series

Parametr Qiymat
Fiber grade (sukut bo'yicha) G.652.D (haqida 90% of shipments); G.657.A1, G.657.A2, G.654.E and OM3 / OM4 / OM5 on request
Attenuation @ 1310 nm ≤ 0.35 dB/km
Attenuation @ 1550 nm ≤ 0.21 dB/km
Fiber count range 2 - 288 cores standard; qadar 576 cores custom (ADSS ikki qavatli ko'ylagi)
Minimal Bendlar radius ≥ 10× cable diameter (statik); ≥ 20× diameter (dinamik)
Long-term tensile strength GYTS/GYTA 600 N; Shakl-8 5 kN; Submarine 4 kN long-term / 10 kN installation
Qattiq qarshilik ≥ 300 N/100 mm (armored series)
Ishlash harorati -40 gacha +70 °C (ochiq havoda); -20 gacha +70 °C (indoor LSZH / PVX)
Dizayn xizmat muddati Outdoor armored 20 yillar; ADSS double-jacket 25–30 years; suv osti kemasi 25 yillar
Sinov 100% drum-by-drum attenuation test; OTDR trace archived per drum

Submarine Cable — Our Deep-Water Line ⭐

Our submarine cable line targets short-haul unrepeated systems — island interconnect, offshore platform tie-in, coastal loops — where a single-span 100 Gb/s link up to 500 km eliminates the cost of subsea repeaters, power feed and maintenance.

  • Depth rating: standard shallow-water build for up to 100 m (most common); deep-water build rated up to 8,000 m
  • Elyaflar soni: qadar 288 tolalar
  • Qurol: shallow-water uses hot-dip galvanized low-carbon round steel wire; deep-water uses high-carbon high-tensile round steel wire with zinc-aluminum alloy coating
  • Kurtka: HDPE for seawater corrosion, water blocking and pressure resistance
  • Tensile: uzoq muddatli 4 kN, short-term installation 10 kN
  • Standartlarga muvofiqligi: GB/T 18480, IEC 60794, ITU-T G.976, GJB 4489
  • Dizayn xizmat muddati: dan kam emas 25 yillar
  • O'rnatish usullari: trench burial (flat silt/sand seabed), surface laying (calm water), casing protection (rocky/reef zones), underwater suspension (bay spans)

Manufacturing Capability

Automated Production Lines with Inline Inspection

Our GYTS / GYTA lines run imported cabling machines, high-speed secondary coating equipment, and dual-layer co-extrusion jacket lines. Inline laser concentricity gauges and real-time OTDR scanners monitor every step. A three-stage water-blocking process controls excess fiber length, tape thermal bonding and jacket extrusion parameters through digital process control.

Annual Output & Stock Position

  • GYTS / GYTA: tens of millions of fiber-kilometers per year across all core counts, with 4–288-core standard configurations kept in stock
  • GYXTY: ~10,000 km per month
  • Indoor distribution cable: 5 production lines × 180 km per line per day
  • ADSS Single-Jacket: 12–48-core kept in stock; MOQ 1 km
  • ASU: 2–24-core standard in stock; same-day shipping for regular configurations
  • Shakl-8: 2–48-core in stock across 4 dedicated extrusion lines

100% Drum-by-Drum Testing

  • Attenuation test on every drum before shipment — not sampling
  • Length tolerance strictly controlled within +1 uchun +2 metres per drum
  • Per-drum OTDR trace archived and provided to buyer on request
  • Tensile, water-penetration and aging test reports available under IEC 60794 metodologiyasi

Container Loading & Qadoqlash

Standard drum length is 1–3 km per wooden reel for most trunk series; custom drum lengths supported on request. Approximate cable-length loading per container for figure-8 and similar profiles:

  • 20 GP container: 800 - 1,200 km of cable
  • 40 Bosh qarorgoh container: 1,900 - 2,800 km of cable

Actual loading depends on cable diameter, drum size and stacking configuration — our sales team will calculate exact quantities against your PO.

Sertifikatlash va muvofiqlik

  • ISO 9001 Sifat menejmenti tizimi, zavod miqyosida
  • IEC 60794 series — optical cable performance, environmental and mechanical test methods
  • BU — European conformity for applicable product lines
  • the / ETL — available for North American market entry
  • CPR — European Construction Products Regulation, for cables installed in permanent buildings
  • RoHS — hazardous substance compliance; certificates renewed annually
  • Submarine cable additionally complies with GB/T 18480, ITU-T G.976 and GJB 4489

Sertifikatlashning qo'llanilishi mahsulot qatori va mo'ljallangan bozorga qarab farq qiladi. Iltimos, maqsadli mamlakatni tasdiqlang, kotirovka so'rashda joylashtirish muhiti va talab qilinadigan standartlar.

Frequently Asked Questions About Fiber Optic Cable Sourcing

1-savol. Sizning minimal buyurtma miqdori qancha?

Standard trunk cable MOQ is 1 km. Indoor distribution cable also 1 km MOQ; custom-colour indoor cable requires 5 km. Submarine cable typically starts at 100 km due to the specialized production line setup. Bow-type drop cable ships from standard stock.

2-savol. Standart etkazib berish muddati nima?

Regular 2–48-core GYTS / GYTA / GYXTY / ASU configurations ship from stock within days. Custom fiber counts, lengths or non-standard jackets: typically 15–25 working days depending on drum count. Submarine cable and 288-core+ builds require project-specific scheduling.

Q3. Which fiber grade do you use as default?

Haqida 90% of our finished cable ships with G.652.D single-mode fiber. G.657.A1 and G.657.A2 bend-insensitive grades are our default for drop cable and tight-space installations. G.654.E for long-haul 400G+ backbone and OM3 / OM4 / OM5 multimode for data-centre indoor cable are available on request.

4-savol. Can you provide OTDR traces and test reports per drum?

Ha. Every drum ships after 100% attenuation testing, with the OTDR trace archived. Written test reports covering tensile, water penetration and thermal aging are available under IEC 60794 methodology on request — useful for project acceptance and customs clearance.

5-savol. Can you customize drum length, colour and marking?

Ha. Standard drums are 1–3 km; longer runs supported on request (masalan. ADSS in 500 m, 1200 m or segmented lengths). Jacket colour customization has a 5 km MOQ. Sequential metre marking, batch code and buyer logo can be printed to your specification.

faq

6-savol. What certifications can you supply for European and North American markets?

Our cable ships with ISO 9001, BU, RoHS and IEC 60794 compliance as standard. the / ETL certifications are supported for North American entry; CPR is available for cable installed in permanent European buildings. Third-party test reports and country-specific certification can be arranged per project.

7-savol. How do I choose between GYTS, GYTA, GYFTY, ADSS and ASU?

Short answer: foydalanish GYTS or GYTA for standard duct / aerial trunk cabling; GYFTY when a non-metallic (unarmored) cable is required; ADSS bitta ko'ylagi for aerial spans up to 300 m in temperate conditions, double-jacket for coastal salt-fog or ice-loaded spans; ASU for short-span aerial + duct dual-use where you want the strength of ADSS without the cost. Detailed matrix above.

8-savol. Do you supply cables suitable for direct burial?

For direct burial we recommend GYTA53 (double-jacket with steel-tape armor) or GYTA with an additional PE protective conduit. Standard single-jacket ASU and ADSS are not designed for direct burial — the buried environment will corrode the jacket over time.

9-savol. What is the warranty and service life?

Standart zavod kafolati 1 yil. Dizayn xizmat muddati: 20 years for standard outdoor armored cable; 25–30 years for ADSS double-jacket and submarine cable; 15 years for ASU with 1:1 defect replacement if the failure is traced to manufacturing.

10-savol. How much cable fits in a shipping container?

For figure-8 and similar profiles: a 20 GP container carries approximately 800–1,200 km of cable; a 40 HQ carries 1,900–2,800 km. Exact loading varies with cable OD, drum size and stacking. Provide us the drum spec and we’ll calculate loading before the PO is placed.

Tezkor taklif oling

Biz ichida javob beramiz 12 soat, qo'shimchasi bilan elektron pochtaga e'tibor bering “@fibconet.com”.

Shuningdek, ga borishingiz mumkin Aloqa sahifasi, batafsilroq shaklni taqdim etadi.