Gyara Fassara
Bincika

Fiber Optic Cable

Fiber Optic Cable Manufacturer — GYTS, GYTA, ADSS, ASU, Ɗiga, Air-Blown Micro & Submarine Cable

FIBCONET has manufactured fiber optic cable in China for 12 shekaru, running dedicated automated lines for stranded loose-tube, central-tube, self-supporting, air-blown micro and submarine cable series.

Combined output on our mainstream armored lines (GYTS / GYTA) reaches tens of millions of fiber-kilometers per year, with stock inventory maintained across 4–288-core standard configurations.

fiber na gani na USB tsarin

Every drum ships after 100% factory testing — attenuation, tensile, water penetration and end-of-drum OTDR trace — against IEC 60794 jerin and other applicable standards. Our submarine cable also complies with GB/T 18480, ITU-T G.976 and GJB 4489 military-grade specifications.

Below are the twelve cable series currently shipping to telecom operators, engineering contractors, power utilities and FTTH integrators across Southeast Asia, Gabas ta Tsakiya, Latin America and Europe. Each product page carries fiber count options, connector-ready pre-termination, and full mechanical / environmental specifications.

Fiber Optic Cable Series We Manufacture

Nau'in Kebul Samfura Aiwatar da aiki Max Fiber Count Key Highlight
Stranded Loose Tube, Steel-Tape Armored GYTS Tushen, m 288 zaruruwa Long-term tensile 600 N; murkushe 300 N/100 mm; 20-year jacket life
Stranded Loose Tube, Aluminum-Tape Armored GYTA Tushen, m (PE conduit for direct burial) 288 zaruruwa Anti-rodent, moisture-blocking, EMI-shielding; UV-additive option extends life +5 shekaru
Central Loose Tube, Non-Metallic GYXTY / GYFXY (FRP-reinforced) Jirgin sama, duct, lightning-prone regions 24 zaruruwa Mai nauyi, all-dielectric; jacket down to 1.1 mm; 10,000 km / month output
Duk-Dielectric Taimakon Kai (ADSS), Single-Jacket ADSS Single-Jacket Jirgin sama, power-line corridors, ya kai har zuwa 300 m 144 zaruruwa Aramid strength member; PE jacket 1.8 mm ± 0.1 mm; 25–40% lower cost than double-jacket
ADSS, Double-Jacket ADSS Double-Jacket Aerial in coastal salt-fog, ƙanƙara, long-span installations 288 (har zuwa 576 custom) 10–15 years extended service life vs single-jacket; 720 h gishiri-spray gwada; UV per GB/T 18899-2023
Aerial Self-Supporting (ASU) ASU / GYFXY-lightweight Short-span aerial & duct dual use, har zuwa 120 m tazara 24 zaruruwa 3,000 h UV without cracking; 15-year warranty with 1:1 defect replacement; lower cost than ADSS
Figure-8 Central-Tube GYXTC8S Aerial with integral messenger, har zuwa 100 m tazara 96 zaruruwa 7×1.2 galvanized steel strand messenger, 5 kN tensile; 30-year UV per IEC 60794-1
Air-Blown Micro Cable GCYFY / GCYFXY Microduct systems 144 zaruruwa (stranded); 24 zaruruwa (central-tube) Outer diameter from 1.8 mm; grooved jacket for extended blowing distance; HDPE or LSZH
FTTH Drop Cable, Bow-Type Self-Supporting ГХХЧ FTTH outdoor drop with steel or FRP messenger 1–4 fibers G.657.A2 default; steel-wire or non-metallic (FRP) messenger; LSZH / PE / PVC jaket
FTTH Drop Cable, Indoor Bow-Type GJXH FTTH indoor drop, tashi 1–4 fibers LSZH jacket standard; G.657.A2 bend-insensitive fiber
USB Rarraba GJFJV / tight-buffer Building risers, indoor cabling, patch cord raw stock 2–24 fibers 5 production lines × 180 km/day; long-term tensile 200 N (2.0 mm); operating −20 to +70 °C
Submarine Cable GYTA33 & deep-water armored bakin teku, island interconnect, offshore platforms, deep-water up to 8,000 m 288 zaruruwa 100 Gb/s unrepeated span up to 500 km; long-term tensile 4 kN, short-term 10 kN; 25-shekara tsara rayuwa; meets GB/T 18480, IEC 60794, ITU-T G.976 and GJB 4489

OPGW (Waya Ground Optical) and photoelectric composite cable are also part of our line for power-utility deployments — see the OPGW product page for structural options and short-circuit current ratings.

fiber optic cable series

How to Choose the Right Fiber Optic Cable

Three questions determine the right cable for a project: where it’s installed, how many fibers it carries, kuma what mechanical / environmental loads it faces.

1. Match the Cable to the Deployment Environment

Deployment Environment Jerin Nasiha Me yasa
Tushen / magudanar ruwa (standard telecom trunk) GYTS or GYTA Makamai, high tensile, 20-rayuwar sabis na shekara
Jirgin sama, lightning-prone region GYFTY / GYXTY (ba karfe ba) or ADSS All-dielectric prevents lightning damage
Aerial along power lines (spans > 100 m) ADSS Single-Jacket (temperate) or Double-Jacket (bakin teku / ƙanƙara) Self-supporting up to 300 m; aramid-yarn strength
Direct burial GYTA53 (double-jacket + steel-tape armor) or GYTA + PE conduit Rodent, crush and moisture protection
Microduct (existing or new) Air-Blown Micro Cable (GCYFY / GCYFXY) 1.8 mm minimum diameter, groove jacket for blow distance
Short-span aerial + duct dual-use ASU Cheaper than ADSS, higher tensile than standard drop cable
Aerial with integral messenger, mid-span Figure-8 GYXTC8S Built-in steel messenger, 5 kN tensile, 100 m tazara
FTTH outdoor drop GJYXCH bow-type self-supporting Steel or FRP messenger; G.657.A2 bend-insensitive fiber
FTTH indoor drop / tashi GJXH indoor bow-type LSZH jacket for building fire code
bakin teku, island interconnect, bakin teku Submarine cable (GYTA33 series) HDPE jacket, galvanized or Zn-Al armored steel wires
Power utility ground wire OPGW Composite power ground + na USB na gani

2. Calculate the Fiber Count You Need

A working formula: total equipment ports × 2, plus a 10–20% spare buffer. For serial-multiplexed devices the count can be lower. Standard fiber counts we stock: 2, 4, 6, 8, 12, 24, 48, 96, 144, 288. Non-standard counts including 576-core (ADSS biyu-jaket) are available on request.

3. Match Jacket and Armor to the Load Profile

  • Standard PE — general outdoor, 20-rayuwar sabis na shekara
  • UV-additive PE — extends outdoor life by ~5 years for high-solar regions
  • AT (hana bin sawu) PE — for ADSS installed near high-voltage lines to resist electrical corrosion
  • LSZH — low smoke zero halogen for tunnels, hanyoyin karkashin kasa, data centres and indoor riser
  • HDPE — submarine, high-crush and pressure environments
  • Steel-tape armor (GYTS) — rodent protection, danshi, EMI shielding
  • Aluminum-tape armor (GYTA) — equivalent protection, lower weight, better in some corrosive environments
  • 316L stainless steel armor — coastal / marine upgrade for figure-8 messenger; Zn-Al plated for corrosion

GYTS vs GYTA vs ADSS — Quick Comparison for Telecom Trunk Cabling

GYTS GYTA ADSS
Sulke Corrugated steel tape Corrugated aluminum tape None (all-dielectric)
Memba mai ƙarfi Wayar karfe (FRP for lightning zones) Wayar karfe Aramid yarn
Aerial span limit ~80 m ~80 m Har zuwa 300 m
Direct burial PE conduit recommended PE conduit mandatory Bai dace ba
Mafi kyau ga Standard duct / m, high-rodent risk Same as GYTS, lower weight Long-span aerial along power poles

Technical Specifications Across Trunk Cable Series

Siga Daraja
Fiber grade (tsoho) G.652.D (game da 90% of shipments); G.657.a1, G.657.A2, G.654.E and OM3 / OM4 / OM5 on request
Attenuation @ 1310 nm ≤ 0.35 dB/km
Attenuation @ 1550 nm ≤ 0.21 dB/km
Fiber count range 2 - 288 cores standard; har zuwa 576 cores custom (ADSS biyu-jaket)
Mafi ƙarancin lanƙwasa radius ≥ 10× cable diameter (a tsaye); ≥ 20× diameter (m)
Long-term tensile strength GYTS/GYTA 600 N; Hoto-8 5 kN; Submarine 4 kN long-term / 10 kN installation
Murkushe juriya ≥ 300 N/100 mm (armored series)
Operating zazzabi -40 ku +70 °C (waje); -20 ku +70 °C (indoor LSZH / PVC)
Zane sabis rayuwa Outdoor armored 20 shekaru; ADSS double-jacket 25–30 years; jirgin ruwa mai tafiya ƙarƙashin ruwa 25 shekaru
Gwaji 100% drum-by-drum attenuation test; OTDR trace archived per drum

Submarine Cable — Our Deep-Water Line ⭐

Our submarine cable line targets short-haul unrepeated systems — island interconnect, offshore platform tie-in, coastal loops — where a single-span 100 Gb/s link up to 500 km eliminates the cost of subsea repeaters, power feed and maintenance.

  • Depth rating: standard shallow-water build for up to 100 m (most common); deep-water build rated up to 8,000 m
  • Ƙididdigar fiber: har zuwa 288 zaruruwa
  • Sulke: shallow-water uses hot-dip galvanized low-carbon round steel wire; deep-water uses high-carbon high-tensile round steel wire with zinc-aluminum alloy coating
  • Jaket: HDPE for seawater corrosion, water blocking and pressure resistance
  • Tensile: na dogon lokaci 4 kN, short-term installation 10 kN
  • Ka'idojin yarda: GB/T 18480, IEC 60794, ITU-T G.976, GJB 4489
  • Zane sabis rayuwa: ba kasa da 25 shekaru
  • Hanyoyin shigarwa: trench burial (flat silt/sand seabed), surface laying (calm water), casing protection (rocky/reef zones), underwater suspension (bay spans)

Manufacturing Capability

Automated Production Lines with Inline Inspection

Our GYTS / GYTA lines run imported cabling machines, high-speed secondary coating equipment, and dual-layer co-extrusion jacket lines. Inline laser concentricity gauges and real-time OTDR scanners monitor every step. A three-stage water-blocking process controls excess fiber length, tape thermal bonding and jacket extrusion parameters through digital process control.

Annual Output & Stock Position

  • GYTS / GYTA: tens of millions of fiber-kilometers per year across all core counts, with 4–288-core standard configurations kept in stock
  • GYXTY: ~10,000 km per month
  • Indoor distribution cable: 5 production lines × 180 km per line per day
  • ADSS Single-Jacket: 12–48-core kept in stock; Moq 1 km
  • ASU: 2–24-core standard in stock; same-day shipping for regular configurations
  • Hoto-8: 2–48-core in stock across 4 dedicated extrusion lines

100% Drum-by-Drum Testing

  • Attenuation test on every drum before shipment — not sampling
  • Length tolerance strictly controlled within +1 ku +2 metres per drum
  • Per-drum OTDR trace archived and provided to buyer on request
  • Tensile, water-penetration and aging test reports available under IEC 60794 hanya

Container Loading & Marufi

Standard drum length is 1–3 km per wooden reel for most trunk series; custom drum lengths supported on request. Approximate cable-length loading per container for figure-8 and similar profiles:

  • 20 GP container: 800 - 1,200 km of cable
  • 40 HQ container: 1,900 - 2,800 km of cable

Actual loading depends on cable diameter, drum size and stacking configuration — our sales team will calculate exact quantities against your PO.

Takaddun shaida da Biyayya

  • ISO 9001 Tsarin Gudanar da inganci, masana'anta-fadi
  • IEC 60794 series — optical cable performance, environmental and mechanical test methods
  • WANNAN — European conformity for applicable product lines
  • da / Mahaifa — available for North American market entry
  • CPR — European Construction Products Regulation, for cables installed in permanent buildings
  • RoHS — hazardous substance compliance; certificates renewed annually
  • Submarine cable additionally complies with GB/T 18480, ITU-T G.976 and GJB 4489

Aiwatar da takaddun shaida ya bambanta ta layin samfur da kasuwar makoma. Da fatan za a tabbatar da ƙasar da ake nufi, yanayin turawa da ma'aunin da ake buƙata lokacin neman zance.

Frequently Asked Questions About Fiber Optic Cable Sourcing

Q1. Menene mafi ƙarancin odar ku?

Standard trunk cable MOQ is 1 km. Indoor distribution cable also 1 km MOQ; custom-colour indoor cable requires 5 km. Submarine cable typically starts at 100 km due to the specialized production line setup. Bow-type drop cable ships from standard stock.

Q2. Menene daidaitaccen lokacin jagora?

Regular 2–48-core GYTS / GYTA / GYXTY / ASU configurations ship from stock within days. Custom fiber counts, lengths or non-standard jackets: typically 15–25 working days depending on drum count. Submarine cable and 288-core+ builds require project-specific scheduling.

Q3. Which fiber grade do you use as default?

Game da 90% of our finished cable ships with G.652.D single-mode fiber. G.657.A1 and G.657.A2 bend-insensitive grades are our default for drop cable and tight-space installations. G.654.E for long-haul 400G+ backbone and OM3 / OM4 / OM5 multimode for data-centre indoor cable are available on request.

Q4. Can you provide OTDR traces and test reports per drum?

Ee. Every drum ships after 100% attenuation testing, with the OTDR trace archived. Written test reports covering tensile, water penetration and thermal aging are available under IEC 60794 methodology on request — useful for project acceptance and customs clearance.

Q5. Can you customize drum length, colour and marking?

Ee. Standard drums are 1–3 km; longer runs supported on request (misali. ADSS in 500 m, 1200 m or segmented lengths). Jacket colour customization has a 5 km MOQ. Sequential metre marking, batch code and buyer logo can be printed to your specification.

faq

Q6. What certifications can you supply for European and North American markets?

Our cable ships with ISO 9001, WANNAN, RoHS and IEC 60794 compliance as standard. da / ETL certifications are supported for North American entry; CPR is available for cable installed in permanent European buildings. Third-party test reports and country-specific certification can be arranged per project.

Q7. How do I choose between GYTS, GYTA, GYFTY, ADSS and ASU?

Short answer: amfani GYTS or GYTA for standard duct / aerial trunk cabling; GYFTY when a non-metallic (unarmored) cable is required; ADSS guda-jaket for aerial spans up to 300 m in temperate conditions, double-jacket for coastal salt-fog or ice-loaded spans; ASU for short-span aerial + duct dual-use where you want the strength of ADSS without the cost. Detailed matrix above.

Q8. Do you supply cables suitable for direct burial?

For direct burial we recommend GYTA53 (double-jacket with steel-tape armor) or GYTA with an additional PE protective conduit. Standard single-jacket ASU and ADSS are not designed for direct burial — the buried environment will corrode the jacket over time.

Q9. What is the warranty and service life?

Standard factory warranty is 1 shekara. Zane sabis rayuwa: 20 years for standard outdoor armored cable; 25–30 years for ADSS double-jacket and submarine cable; 15 years for ASU with 1:1 defect replacement if the failure is traced to manufacturing.

Q10. How much cable fits in a shipping container?

For figure-8 and similar profiles: a 20 GP container carries approximately 800–1,200 km of cable; a 40 HQ carries 1,900–2,800 km. Exact loading varies with cable OD, drum size and stacking. Provide us the drum spec and we’ll calculate loading before the PO is placed.

Samun Magana Mai Sauri

Za mu amsa a ciki 12 hours, da fatan za a kula da imel tare da suffix "@fibconet.com".