Dezie Ntụgharị asụsụ
Chọọ

Usoro MPO

MPO / MTP Data Center Cabling Manufacturer - Cassettes, Patch panel, Igwe eriri akpati na eriri patch
Fibconet na-emepụta 10 usoro nke MPO / MTP fiber optic ngwaahịa maka 40g, 100G, 400G na 800G data center cabling. Ahịrị ngwaahịa ahụ na-ekpuchi modul cassette, 1U rack patch panels, MPO ogwe na patch eriri, MPO-na-LC mmebi, loopbacks na MPO/MTP Cleaners - zuru ezu iji wuo njikọ dị elu zuru oke site na MDA gaa n'ọdụ ụgbọ mmiri mgba ọkụ na-agbakwunyeghị onye na-ebubata nke abụọ..

Mmepụta na-aga na polishing MPO raara onwe ya nye, rịbọn splicing na 3D interferometer ahịrị. Mbupụta kwa ọnwa ruru 150,000 iberibe n'ofe ezinụlọ MPO. Ọnụ ọgụgụ fiber na-erukwa 72 eriri kwa njedebe MPO maka ngwa azụ azụ 400G/800G. Enwere ike chịkwaa mfu ntinye nke otu fiber 0.15 dB na mgbakọ e ji ferrules ndị Japan bubata wuo, na 0.20-0.35 dB na-ahụkarị na ọkọlọtọ Sanhuan ferrules na-ewu ụlọ..

Every finished cable is 100% inspected for insertion loss, Laghachi, end-face geometry, polarity, eriri usoro, ogologo na ọdịdị. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 MPO / MTP Products We Manufacture
Otu 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.

Nlereanya
Ọnụọgụ eriri
Interface
Ojiji a na-ahụkarị

Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 ka 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion

12/24 Ihe Ngwọta Ngosi Dị Elu dị elu MPO Cassette Module
12 ma ọ bụ 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base

8/12/24 MPO MTP Base ka 24 LC Ultra High density 1U Modular
Ruo 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows

Otu 2 — Rack Patch Panels
Chassis 1U 19-inch nke tọgbọrọ chakoo ma ọ bụ kpọkọtaburu iji jide modul cassette na iji hazie eriri akpati n'elu akwa ahụ..

Nlereanya
Nha akwa akwa
Na-ebugo
Ojiji a na-ahụkarị

Ebe nchekwa data 19-inch Standard Rack MPO Patch Panel
1U
Chassis efu maka cassettes
Ọkọlọtọ MDA, modul ewu

1U 19-inch Rack LC MTP®/MPO Patch Panel achịkọtaburu.
1U
LC n'ihu akwụsịlarị, MPO azụ
Nkwụnye na-egwu egwu, enweghị mgbakọ ubi

Otu 3 - Ihe mgbochi eriri na eriri akpati

Njikọ anụ ahụ dị n'etiti kaseti MPO, patch paịlị, transceivers na MPO ọkpụkpụ azụ na-agba ọsọ.

Nlereanya
Nhazi
Fiber Nhọrọ
Ojiji a na-ahụkarị

Ụlọ ọrụ tupu akwụsị MPO-MPO 3.0mm LSZH Patch Cord / Igwe eriri
MPO ka MPO
OS2 / OM3 / OM4 / OM5
Ogwe azụ, MDA na EDA

Fiber Optic MPO MTP Njikọ Njikọ eriri
MPO ka MPO
OS2 / OM3 / OM4 / OM5
Ọkpụkpọ mkpirisi mkpụkọ-na-akwakọba

FTTA MPO/MTP eriri eriri eriri fiber optic patch
MPO ka MPO, jaket dị n'èzí
OS2 / OM3 / OM4
Ebe ọdụ ụgbọ ala FTTA na njikọ dị n'èzí

Otu 4 - Akwụghachi azụ
Eji anwale ọdụ ụgbọ mmiri transceiver, kaseti na-aga n'ihu na iguzosi ike n'ezi ihe na-enweghị ịdọrọ njikọ okporo osisi zuru ezu.

Nlereanya
Interface
Fiber
Ojiji a na-ahụkarị

OM3 MM MTP/APC Nwanyị MPO Loopback
MTP/APC nwanyi
OM3 multimode
Multimode transceiver na cassette ule

Otu 5 - Ngwa nhicha
Mmetọ ihu ngwụcha bụ otu ihe kacha akpata ọdịda ntinye MPO. Otu onye na-ehicha ihe nke ọma n'otu rack bụ omume ọrụ ọkọlọtọ.

Nlereanya
Dabara
Ojiji a na-ahụkarị

Alldị niile dabara MPO/MTP Cleaner
Ihu njedebe MPO/MTP niile
Nhicha ubi tupu ịlụ; ngwa ọrụ

Kedu ihe bụ MPO / MTP na otu esi ahọrọ ngwaahịa ziri ezi
MPO vs MTP - Otu ọkọlọtọ, Ụdị dị iche iche
MPO (Ọtụtụ fiber na-efe efe na) bụ ọkọlọtọ multi-fiber njikọ nke akọwapụtara na IEC 61754-7. MTP® bụ mmejuputa aha-aha US Conec nke otu ọkọlọtọ MPO, ya na ntachi obi na-arụ ọrụ siri ike na njide ntuziaka-ndụ, ibu mmiri na nchekwa rịbọn dị n'ime. Ha abụọ na-ejikọta ibe ha ma na-agbaso otu eriri ọnụ na iwu polarity. Fibconet na-arụpụta ọkọlọtọ MPO ma na-enye MTP-dakọtara na-ewuli na arịrịọ; spec optical n'okpuru bụ otu.
Polarity - Ụdị A, Ụdị B, Ụdị C

Polarity
Usoro eriri
Ojiji a na-ahụkarị

Ụdị A (Kwụ ọtọ)
1↔1, 2↔2 … 12↔12 ogologo-site
Ogwe osisi-na-atụ nwere A-ba-B duplex crossover n'ime eriri patch

Ụdị B (tụgharịa)
1↔12, 2↔11 … 12↔1 tụgharịa kpamkpam
Njikọ ozugbo na SFP+ / Ndị transceivers QSFP; Ọtụtụ mgbe maka 40G/100G breakout

Ụdị C (Ụzọ-swap)
Ụzọ abụọ dị n'akụkụ gbanwere: (1↔2, 2↔1), (3↔4, 4↔3) …
Cable nwere ụzọ abụọ tụgharịa

Njehie polarity bụ otu ihe na-ebute ọdịda njikọ na sistemụ MPO. Kwenye polarity na ọkwa RFQ; anyị na-ebuga Ụdị A / B / C kwa ụgwọ ihe onwunwe gị.
Gender - Nwoke (na atụdo) vs Nwanyi (enweghị atụdo)

Nwoke: ntụzịaka abụọ na-esi na njedebe-ihu pụta. Eji na ofu / patch-panel agwụ.
Nwanyị: enweghị atụdo, oghere ndu-ndụ abụọ naanị. Ejiri ya na akụrụngwa / mbugharị- jumper ọgwụgwụ.

Mmekọ nwoke na nwanyị na-ezighi ezi na RFQ = a ga-akwụsịghachi ogbe niile. Na-akọwapụta nwoke-Nwanyị mgbe niile, Nwanyị-Nwanyị ma ọ bụ Nwoke-Nwoke na ọkwa ngụ.
Ụdị eriri - dakọtara na ọnụego data na anya

Fiber
Ogologo ogologo
10G iru
40G / 100G iru
Ojiji a na-ahụkarị

OM3 multimode
850 nm
550 m
100 m / 100 m (SR4)
Obere akwa-na-akwakọba, ọnụ ahịa na-ewuli elu

OM4 multimode
850 nm
550 m
150 m / 150 m (SR4)
Ọkpụkpụ azụ etiti data ọkọlọtọ

OM5 multimode
850 & 953 nm SWDM
550 m
≥ 150 m; na-akwado 400G SR4.2
ụyọkọ AI na ọkpụkpụ azụ supercompute na-esote

OS2 singlemode
1310 / 1550 nm
10 km +
10 km + (LR4 / DR4)
Inter-ụlọ, kampos, Ọnụ ego nke DCI

Ntinye Ọkwa Mgbaghara - Ọkọlọtọ vs Ọdịghị Mbelata

Ọkwa
Kachasị IL kwa ụzọ abụọ
Nlaghachi azụ
Ojiji a na-ahụkarị

Ọkọlọtọ (SM APC)
≤ 0.70 dB
≥ 55 dB
Ụlọ ọrụ LAN, ọkọlọtọ data-center na-agba ọsọ

Mfu dị ala / Iruelite (SM APC)
≤ 0.35 dB (ụdị 0.25 dB)
≥ 55 dB
Cabinet-to-cabinet 100G ọkpụkpụ azụ dị elu

Ultra Low-Loss (Japanese ferrule)
0.15 dB kwa otu eriri
≥ 55 dB
400G / 800G AI ọkpụkpụ azụ; ogologo njikọ mmefu ego

Ọkọlọtọ (MM PC)
≤ 0.50 dB
≥ 20 dB
OM3/OM4 obere data etiti na-agba

Mfu dị ala (MM PC)
≤ 0.35 dB (ụdị 0.20 dB)
≥ 20 dB
OM4/OM5 ọkpụkpụ azụ njupụta dị elu

Nkọwapụta teknụzụ

Rịba ama: ụkpụrụ ndị dị n'okpuru bụ ezinụlọ-ahụkarị n'ofe 10 usoro, ọ bụghị otu-SKU mpempe akwụkwọ. Rịọ anyị maka akụkọ nyocha akọwapụtara nke ọma na ọkwa RFQ; anyị na-eziga ya n'okpuru nọmba akụkụ nlereanya.

Oke
Uru a na-ahụkarị
Ikwu

Ọnụọgụ fiber kwa ngwụcha MPO
4 / 8 / 12 / 16 / 24 / 48 / 72
Ọkọlọtọ 12F na 24F; 72F maka 400G/800G AI ọkpụkpụ azụ

Ụdị eriri
OS2 (G.652.D, G.657.A1/A2), OM3, OM4, OM5
G.657.A2 maka ntugharị radius siri ike

Polarity
Ụdị A / Ụdị B / Ụdị C
Ụdị B bụ ndabara maka 40G/100G breakout

okike
Nwoke (na atụdo) / Nwanyị (enweghị atụdo)
Akwụsị abụọ a nwere ike ịhọrọ kwa ọdụ ụgbọ mmiri

Nchacha ihu ngwụcha
APC (singlemode) / PC (multimode)
APC green, PC beige/aqua

Mfu ntinye (otu eriri)
0.15 - 0.35 dB kwa ọkwa
0.15 dB nwere ike iji ferrules ebubata na Japan

Weghachite mfu
≥ 55 dB (SM APC), ≥ 45 dB (SM PC), ≥ 20 dB (MM PC)

Mating anwụ ngwa ngwa
≥ 500 okirikiri, IL ọrụ ≤ 0.2 dB
Ndokwa ntụzịaka nwere njiri tupu ibu ihe na-agbanwe

Rịọs gbagọọ kacha nta
MPO njedebe ≥ 30 mm; LC breakout njedebe ≥ 20 mm
Static 15 mm, ike 30 mm na G.657.A2 eriri

Ọnọdụ okpomọkụ na-arụ ọrụ
-20°C ruo +60°C
Arụmọrụ anya kwụsiri ike n'ofe oke

Ntinye / iru mmiri
IP50; 45Celsius C / 95% RH; 24-awa nnu ịgba
Ọ bụghị maka ogologo oge eji eme ihe n'èzí enweghị nchebe ọ gwụla ma FTTA nwere jaketị

Ogologo ogologo
0.2 ka 300 m omenala; · Dakọtara na ma 3mm drop cable na 3x2mm flat cable · Ngwa ngwa na mfe echichi 0.5 ka 30 m
Kwa ụdị

Igwe eriri OD
3.0 mm ahụkarị (8/12/16/24F); 5.0 mm (48F)
Ọnụ ọgụgụ eriri dị elu = OD buru ibu

Jaketị
ọkọlọtọ LSZH; OFNR / OFNP na arịrịọ
Kwesịrị ekwesị maka ụlọ ọrụ data, elu na plenum

Nwale ogologo ife efe
1310 / 1550 nm (SM), 850 / 1300 nm (MM)

Akwụkwọ ikike
1 afọ; chepụta ndụ ruo 10 afọ
Mgbanwe mpaghara kpuchiri n'ime oge ikike

Ike nrụpụta na njikwa ogo
Line Production na ike kwa ọnwa
Ọrụ nne na nna Fibconet n'ime ngwa ngwa ngwa anya malitere laa azụ 1994. MPO / Ahịrị MTP na-arụ na akụrụngwa raara onwe ya nye: jigs na-ekewa eriri eriri akpaaka, Sub-micron 3D polishing machines na ebe a na-akpụzi injection agbakwunyere maka nkwado otu akụkụ na mgbọrọgwụ mgbawa kama ikpo ọkụ dị mfe.. Mbupụta kwa ọnwa ruru 150,000 iberibe. Ọkọlọtọ iwu nke ọtụtụ puku iberibe ụgbọ mmiri na 7- 12 ụbọchị; nnukwu iwu n'elu 20,000 iberibe ụgbọ mmiri n'ime 15- ụbọchị 20.
Njikwa ihe onwunwe dị n'elu
Eriri mpe mpe mpe mpe akwa MPO dị mma naanị ka ferrule ya, eriri ya na rịbọn ya splice. Anyị na-ejikwa nchịkọta elu karịa naanị nzọụkwụ mgbakọ:

Ferrules: ụlọ Sanhuan ferrules na ọkọlọtọ ewuli; ferrules ndị Japan bubata (Klas Sumitomo) na ultra-obere ọnwụ na-ewuli elu. Ha abụọ nwere ike ịhọrọ otu ịtụ.
Fiber: YOFC / Fiberhome / HTGD otu-mode na OM3/OM4/OM5 multimode, ya na G.657.A2 na-ehulata eriri na-adịghị emetụ n'ahụ maka ịkwọ ụgbọ okporo ígwè siri ike.
Aramid yarn: ọkọlọtọ Taihe; DuPont Kevlar dị na arịrịọ.
Ngwakọta jaket: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.

100% Nyocha ogo

Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
Polarity na eriri usoro: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.

Asambodo na nnabata
Fibconet na-arụ ọrụ n'okpuru agbakwunyere ISO 9001 / ISO 14001 / ISO 45001 usoro nlekọta na-ekpuchi àgwà, gburugburu ebe obibi na ahụike ọrụ & nchekwa. Raw-material RoHS reports ship by default. Product-level compliance — CE, rute, nke, ETL — is issued per model and per target market. Asambodo itinye n'ọrụ na-adịgasị iche site na ihe achọrọ na ngwaahịa. Zitere anyị ahịa ebumnuche gị yana ndepụta ihe nlereanya; we return the applicable certificate set with the quotation.
Nkwakọ ngwaahịa, OEM na Nhọrọ Omenala
Standard Packaging

Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, nke ukwu, polarity and gender code.

OEM na Nhọrọ Omenala

Ogologo: ogologo ọ bụla si 0.2 m na 300 m, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 cm) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3×8 / 4×6; 16F to 2×8; 48F to 6×8; ruo 6 MPO connectors per single end on MPO-to-MPO breakouts.
Polarity: Ụdị A / B / C per port; internal crossover on Type B for direct SFP mating.
Ferrule grade: domestic Sanhuan or Japanese-imported per fiber-count / IL grade selection.
Jacket color: mmiri (OM3), erika violet (OM4), lime green (OM5), edo edo (OS2), custom RAL.
Breakout root protection: onweghi (short runs), nylon boot (standard rack), braided sleeve (high-wear).
OEM label and printing: on connector body, PE bag and master carton.
Custom packaging: PE bag and carton design per your artwork, MOQ 30,000 pcs for full custom packaging run.
Ihe atụ: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.

Ajụjụ a na-ajụkarị
Q1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Q2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100G, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Q3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100G / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / SC / FC on the other?
Ee. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
Q5. Are both ends symmetric on MPO-to-MPO breakout cables?
Ee. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. Ruo 6 MPO connectors per single end are supported.
Q6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100GSR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; anyị na-ebuga Ụdị A / B / C kwa ụgwọ ihe onwunwe gị.
Q7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 dB. Ultra low-loss builds with Japanese ferrules reach 0.15 dB kwa otu eriri. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
Q8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
Ee. Every cable and every fiber core is tested for insertion loss, Laghachi, end-face geometry, polarity, eriri usoro, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
Q9. Can I get samples before placing a bulk order?
Ee. Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
Q10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 iberibe. Standard orders of several thousand pieces ship in 7–12 days from stock. Bulk orders above 20,000 pieces ship in 15–20 days. Custom packaging with full artwork runs from an MOQ of 30,000 pcs.
Q11. Can these MPO products be used outdoors?
The standard MPO line is optimised for data hall, MDA and rack environments (IP50, -20°C ruo +60°C, LSZH). For outdoor and FTTA applications, use the FTTA MPO/MTP Fiber Optic Patch Cord with an outdoor jacket, or ask for a custom outdoor build. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. What is the warranty?
Standard warranty is 1 afọ; design service life is up to 10 afọ. Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.

Nweta Quote ngwa ngwa

Anyị ga-aza n'ime 12 awa, biko ṅaa ntị na email nke nwere suffix "@fibconet.com".

Ọzọkwa, ị nwere ike ịga na Ibe kọntaktị, nke na-enye ụdị nkọwa zuru oke.