Fibconet e hlahisa 12 series of outdoor fiber optic splice closures (also called joint closures, cable closures, or in field slang dome cans) for OSP splicing between feeder, distribution and drop cables. Capacity ranges from 12 cores for FTTH drop junctions up to 840 cores for backbone and long-haul splice points. Sealed to IP68, housings are PP+GF, PPR or metal-braced polymer with a 15 to 25-year design field life. Our passive optical component roots trace back to 1994, and the same in-house tooling and test discipline built for PLC splitters now runs the splice closure line.

Two body types cover the two OSP install methods: dome (vertical) closures for pole, wall and direct-buried joints, le tse otlolohileng (inline) closures for manhole, handhole and figure-8 aerial splice points. Selected dome models ship pre-loaded with 1×8 or 1×16 PLC splitters and act as PON hub points inside a Quick ODN / pre-terminated FTTH deployment. Enclosures accept mechanical, heat-shrink or silicone sealing per model.
The sections below list the 12 models grouped by body type, then cover Dome-vs-Horizontal selection logic, technical specifications, manufacturing capability, phutheloana, LBH, and a quotation channel.
Cylindrical body with a single base plate carrying all cable ports. Best suited to pole-mount, wall-mount and direct-buried joints where cables enter from one end. The two splitter-loaded models below double as PON hub points inside a Quick ODN deployment.
| Mohlala | Core Capacity | Ho tiisa / Rating | PON hub role | Tšebeliso e Tloaelehileng |
|---|---|---|---|---|
| IK10 IP68 96 Core Huawei-Compatible Access Terminal Closure | 96 li-cores | IP68 / IK10 impact | - | Huawei-standard access node, palo kapa lebota |
| 96/144 Ho koaloa ha Core Dome (Pole / Lerako / Ka tlas'a lefatše) | 96- likotoana tse 144 | IP68 | - | Multi-scenario OSP splice, thaba efe kapa efe |
| 96/144 Ea mantlha 100 kPa 25-Year Splice Close | 96- likotoana tse 144 | IP68 / 100 kPa ho ts'oara khatello ea moea | - | Litholoana tsa mokokotlo oa nako e telele tse hlokang teko ea khatello |
| 144 Core Metal-Bracket IP68 Dome Ho koaloa | 144 li-cores | IP68 | - | Terei e nang le tšepe e nang le tšepe bakeng sa ho sisinyeha ho phahameng kapa mojaro o boima oa cable |
| IP68 288 Koalo ea Dome e nang le bokhoni bo phahameng haholo | 288 li-cores | IP68 | - | Sebaka sa mokokotlo oa mokokotlo o phahameng |
| 1:8 / 1:16 PLC Splitter IP68 Dome (22000 N / 10 ho boloka cable ea cm) | Dome e kentsoeng ka sekhahla | IP68 / 22000 N thapo e hula | Ee - Hub ea ODN e potlakileng | PON hub e kopanyang splice le 1 × 8 kapa 1 × 16 petsoha |
| IP68 1:8 PLC Splitter e felisitsoeng esale pele ho koaloa ha FAT | Splitter + likou tsa FAT | IP68 | Ee - setsi sa PON se felisitsoeng pele | Hokela le ho bapala hub ea PON e nang le likou tsa lithapo |
'Mele o molelele o nang le likou tsa cable ka mahlakoreng ka bobeli. E ratoa bakeng sa mokoti, lesoba, Aerial figure-8 span le ntlha efe kapa efe moo likhoele li kenang le ho tsoa ka axis e le 'ngoe.
| Mohlala | Core Capacity | Ho tiisa / Rating | Tšebeliso e Tloaelehileng |
|---|---|---|---|
| PP+GF / PPR IN-LINE 2-in-2-out 12 Ho Koalloa ha Core Splice | 12 li-cores | IP68 / mechanical seal | FTTH drop junction, aerial or handhole |
| 48 Core 1-in-2-out Inline Cable Closure | 48 li-cores | IP68 | Small branch inline splice |
| 15+ Service Years PP+GF IP68 2-in-2-out Inline Closure | Ho fihlela ho 96 li-cores | IP68 / 15+ years field life | Mid-density distribution splice with long life claim |
| 96 Core Silicone-Protection Horizontal Splice Closure (Customized) | 96 li-cores | IP68 / silicone sealing | Manhole splice with elevated moisture and chemical exposure |
| 576 / 840 Core Heat-Shrink Seal IP68 Cable Closure | 576–840 cores | IP68 / ho honyetsa mocheso | Long-haul backbone splice, high-count ribbon or loose-tube |
A splice closure protects, seals and organises spliced fibers at any point along an OSP cable route. The body shape follows the physical install location, not the fiber count.
| Dome (Vertical) | Horizontal (E mocheng) | |
|---|---|---|
| Keno ea thapo | All ports on one base plate | Ports at two opposite ends |
| Molemo ka ho fetisisa kenya | Pole, lebota, patoa ka kotloloho, lesoba la letsoho ho tloha hodimo | Mokotla, setšoantšo sa moeeng-8 span, tray-mount inline |
| Palo e tloaelehileng ea mantlha | 96, 144, 288 - e atolosoa ka literei tse ekelitsoeng | 12, 48, 96, 576, 840 - sekala se nang le bolelele ba 'mele |
| Phihlello | Phahamisa sebaka, literei tsohle tsa splice li pepesitsoe | Arola khetla, literei tsa phihlello ho latela axis |
| PLC splitter loading | Tloaelehileng (PON hub role) | E sa tloaelehang, e sebedisoang haholo bakeng sa splice e hloekileng |

| Matla a mantlha | Karolo ea marang-rang | Lethathamo la mofuta oa 'mele |
|---|---|---|
| 12- likotoana tse 48 | FTTH e theoha / mateano a kabo | E mocheng, mechanical seal |
| 96 li-cores | Sebaka sa phihlello sa PON node, setsi sa setsi sa motheo | Dome (Huawei-e lumellana kapa borakete ea tšepe) |
| 144 li-cores | Phatlalatso-lera aggregation | Dome, terei-katoloso |
| 288 li-cores | Metro backbone splice point | Dome, boemo bo phahameng |
| 576–840 cores | Mokokotlo o molelele, lente le phahameng | E mocheng, tiiso e fokotsang mocheso |
Hlokomela: the values below are family-typical ranges across the 12 letoto, ha se database e le 'ngoe ea SKU. Re kope bakeng sa tlaleho ea tlhahlobo e khethehileng sethaleng sa RFQ; re e romella tlas'a nomoro ea karolo ea mohlala.
| Paramethara | Boleng bo Tlwaelehileng | Maikutlo |
|---|---|---|
| Matla a mantlha | 12 ho 840 li-cores | Ka mohlala; expandable via added splice trays |
| Thepa ea matlo | PP+GF, PPR, ABS+PC or metal-braced polymer | Selected per model and environment |
| Sealing grade | IP68 | All outdoor OSP models |
| Impact resistance | Up to IK10 on selected models | Metal-bracket and IK10-rated series |
| Mokhoa oa ho tiisa | Mechini / ho honyetsa mocheso / silicone | Ka mohlala |
| Air-pressure hold | 100 kPa on selected models | For pressurised OSP networks |
| Cable retention (axial pull) | Ho fihlela ho 22,000 N / 10 cm on selected models | Splitter-loaded dome rated for heavy pull |
| Cable entry ports | 1-ho-2 ho tsoa, 2-ho-2 ho tsoa, 4-in-4-out per model | Additional ports available on custom builds |
| Main cable diameter | Typically Φ7–Φ16 mm | Model-dependent; branch cable Φ5–Φ11.5 mm |
| Splice Tray | Stackable, 12 kapa 24 splices per tray | Both fusion and mechanical splice trays supported |
| Mocheso oa ho sebetsa | −40°C ho ea ho +65°C | Sebaka sa polokelo −35°C ho ea ho +55°C ka mokhoa o mong oa ho tsamaisa thepa |
| Bophelo ba tšimo ea moralo | 15 ho 25 lilemo tse kantle | Ka mohlala; PP+GF e nang le lisebelisoa tsa tlatsetso ea UV 25 lilemo |
| Litekanyetso tsa tlhahlobo ea litšupiso | IEC 61753-1, YD/T 814, GR-771 | E sebelisoa ho latela tlhoko ea projeke |
Semelo sa puisano sa Fibconet se qala morao koana lilemong tsa bo-1990. Metso ea rona ea ho etsa karolo ea passive optical e qala ka 1994 e nang le feme ea ho arola ea PLC; khamphani e ile ea thehoa ka molao 2000 mme kajeno e sebetsa ka 300+ basebetsi ba mantlha le marangrang a atolositsoeng a ho etsa libaka tse ngata ho fihlela ho 800 basebetsi le baenjiniere ho pholletsa le China. Mokhoa o ts'oanang oa lisebelisoa le taeo ea liteko e etselitsoeng tlhahiso ea PLC e nang le palo e phahameng haholo e se e tsamaisa mohala oa ho koala splice., ho kenyelletsa ho bōptjoa ha ente ea PP + GF le matlo a PPR, ho etsa terei ea splice, le kopano e tletseng mojaro.
Ho koaloa ha li-splice ho tšepahala feela joaloka lisebelisoa tse ka hare ho tsona. Re laola stack ea holimo ho e-na le mohato oa kopano feela:

Fibconet operates under an integrated ISO 9001 / ISO 14001 / ISO 45001 tsamaiso ea tsamaiso e koahelang boleng, tikoloho le bophelo bo botle mosebetsing & polokeho. Raw material RoHS reports are supplied by default with every shipment.
Product-level compliance is issued per model and per target market. Depending on the model list and destination country, we can support SETS'OA, RoHS, FINYELLANG, the, ETL, CPR, ANATEL, CCA, TLC and other market-entry documents. Applicable test reports against IEC 61753-1, YD/T 814 le Telcordia GR-771 reference standards are provided at project scale.
Tšebeliso ea Setifikeiti e fapana ho ea ka litlhoko tsa sehlahisoa le morero. Re romelle 'maraka oo u o lebelletseng le lenane la mehlala, 'me re khutlisa setefikeiti se sebetsang le khotheishene.
All four are the same product family — an outdoor enclosure that houses and seals spliced fibers along an OSP cable route. “Splice closure” le “joint closure” are the standard English terms. “Dome can” le “炮筒” are field slang for the dome (vertical) body style. The Chinese term “熔接包” refers to the same category and is common in Chinese-language RFQs from Southeast Asia and Africa.
A splice closure protects and organises spliced fibers along an OSP cable route; there is no active drop-cable termination for subscribers. A distribution box (MAFUTA) terminates drop cables into adapter ports and often houses the last-mile splitter. Splice closures sit deeper in the network; distribution boxes sit at the drop point closest to homes.
Choose dome when cables enter from a single direction — pole-mount, lebota-thaba, patoa ka kotloloho, or hand-hole accessed from above. Choose inline when cables enter and exit along the same axis — manhole splice, setšoantšo sa moeeng-8 span, or tray-mount along a linear run.
Match the closure to the largest cable at the splice point plus a spare tray for future expansion. FTTH drop junctions typically use 12–48 core inline closures. PON access nodes use 96–144 core dome closures. Metro backbone splices use 288 li-cores; long-haul trunk splices use 576 kapa 840 cores in heat-shrink inline bodies.
For direct-buried and pressurised networks, use a mechanical-seal dome with 100 kPa ho ts'oara khatello ea moea; the seal is verifiable in the field and re-enterable for future splice work. Heat-shrink is more permanent but not re-enterable without cutting.
Ee. Dome closures can be shipped with a 1×8 or 1×16 PLC splitter pre-terminated at factory. The 1:8 / 1:16 PLC Splitter Dome model is rated for 22,000 N / 10 cm cable retention so the housing tolerates heavy drop-cable pull. Splitter chips are Shijia or Korean-source, and pigtails use G.657.A2 fiber from major Chinese fiber brands.
PP+GF and PC+ABS housings with a UV stabiliser additive package hold 15 ho 25 years of outdoor service, depending on model. Ask us for the specific model’s material spec if your project tender requires a stated design life.
Ee. IEC 61753-1, YD/T 814 and GR-771 test reports are available per model. Raw material RoHS reports ship by default. Market-entry certificates such as CE, FINYELLANG, the, ETL, CPR, ANATEL, CCA and TLC are issued per model and per target market. If a certificate you need is not already on file, we can arrange third-party testing at project scale.
MOQ starts at 100 pcs on standard configuration; custom builds are typically 500–1,000 pcs. Standard orders ship in 15–25 days; custom builds in 25–40 days. [TBC: confirm exact values per model at RFQ stage.]
Ee. Pole-mount and wall-mount hardware is included on the dome closures. Aerial figure-8 mounting kits for inline closures are supplied on request. Manhole tray mounts and cable-management brackets are quoted with the closure.
Ee. Our splitter-loaded dome closures — the 1:8 / 1:16 PLC Splitter Dome and the pre-terminated FAT closure — act as PON hub points inside a Quick ODN system. They pair with our pre-terminated drop cables, Libaka tsa MPO, sub boxes and asymmetric splitters to reduce on-site splicing, cut installation labor, and make FTTH rollout more predictable. If your project is a new FTTH build in a labor-cost-sensitive market, ask for a matched Quick ODN configuration when you send the RFQ.
Re tla arabela ka hare 12 lihora, ka kopo ela hloko lengolo-tsoibila le nang le suffix "@fibconet.com".
Hape, u ka ea ho Leqephe la ho Kopana, e fanang ka foromo e qaqileng haholoanyane.