FIBCONET manufactures fiber optic కనెక్టర్లు మరియు అడాప్టర్లు covering the full range of formats used in FTTH access, data-centre cabinets, telecom central offices and outdoor deployments — from standard SC / LC / FC / ST / MPO / MTR / E2000 to IP67 / IP68 జలనిరోధిత outdoor-rated connectors and field-assembly (fast) connectors for on-site termination.

Every connector and adapter ships after 100% factory inspection — end-face 3D interferometer for MPO, insertion loss and return loss measurement on all fiber types, and mating durability verification against IEC 61754 మరియు Telcordia GR-326-CORE (తరగతి R) methodology. Ferrules are Sanhuan (Sumitomo on request), and connector bodies come in standard telecom grade through outdoor waterproof PEI / PDLC housings.
An adapter (also called coupler or mating sleeve) is the passive component that joins two connectors face-to-face inside an ODF panel, patch panel, wall plate or termination box. It aligns the two ferrules within tight concentricity tolerance so the light passes across the junction with minimum loss and reflection.
| Connector Format | Sleeve Material | సాధారణ చొప్పించడం నష్టం | రిటర్న్ లాస్ |
|---|---|---|---|
| ఎస్సీ | Ceramic (జిర్కోనియా) | ≤ 0.2 dB | UPC ≥ 50 dB; APC ≥ 55 dB |
| LC | Ceramic (జిర్కోనియా) | ≤ 0.2 dB | UPC ≥ 50 dB; APC ≥ 55 dB |
| FC | Ceramic (జిర్కోనియా) | ≤ 0.2 dB | UPC ≥ 50 dB; APC ≥ 55 dB |
| ST | Ceramic (జిర్కోనియా) | ≤ 0.2 dB | UPC ≥ 50 dB |
| MPO / MTP | Precision-molded polymer with pin alignment | ≤ 0.35 dB average (తక్కువ-నష్టం) | ≥ 55 dB (APC) |
| E2000, MTR, MU | Ceramic | ≤ 0.2 dB | UPC ≥ 50 dB; APC ≥ 55 dB |
లో అందుబాటులో ఉంది simplex, duplex and quad ఆకృతీకరణలు, with mounting flanges for standard ODF drawer, wall plate, patch panel and custom panel cutouts. Colour coding follows the industry convention — blue for UPC, green for APC, aqua for OM3/OM4, lime green for OM5, beige for OM1/OM2 — so any technician can identify the format at a glance.

Our connector line splits into three families depending on how the fiber is terminated:
| టైప్ చేయండి | ముగింపు పద్ధతి | ఉత్తమమైనది |
|---|---|---|
| Factory-Terminated Connector (polished on our patch cord line) |
Fusion-splice, epoxy + polish in factory | ప్యాచ్ త్రాడులు, పిగ్టెయిల్స్, ODF pre-terminated cabling — highest and most consistent optical performance |
| Field-Assembly (Fast) కనెక్టర్ | Mechanical splice on-site, no fusion splicer required | FTTH field deployment, drop-cable termination, emergency repair — see our dedicated Fast Connector category for the full line |
| జలనిరోధిత / Outdoor Connector (PDLC, PEI, IP67 / IP68) |
Pre-terminated cable assembly with sealed housing | Base-station RRU, outdoor equipment, telecom compatibility (HW / ZTE / Ericsson), harsh-environment interconnect |
For pre-terminated cable assemblies, connectors are integrated onto FIBCONET patch cords in-house — giving you traceable ferrule origin, insertion loss test report per core, and consistent batch performance. For field-assembly connectors, our dedicated Fast Connector category covers threaded self-locking, alligator-mouth, drawer-type, CCTC single-ceramic, three-ring double-ceramic and other field-installable formats used in FTTH last-mile projects.
All three describe how the ferrule end-face is polished, and each gives a different return loss value.
| పోలిష్ రకం | రిటర్న్ లాస్ | Where to Use |
|---|---|---|
| PC (శారీరక సంపర్కం) | ≥ 40 dB | Legacy telecom, low-cost general use — largely superseded by UPC |
| UPC (అల్ట్రా ఫిజికల్ కాంటాక్ట్) | ≥ 50 dB | Data centres, ఎంటర్ప్రైజ్ నెట్వర్క్లు, most FTTH indoor cabling — the mainstream default |
| APC (కోణ భౌతిక సంపర్కం, 8° polish) | ≥ 55 dB | సోమ / FTTH outside plant, CATV RF-over-glass, DWDM — anywhere high return loss is critical to prevent signal reflection |
Rule of thumb: use APC (green connector) for anything carrying an RF-modulated signal or a PON drop; UPC (blue connector) for standard data traffic. Never mate UPC to APC — the polish angle mismatch will introduce significant loss and can damage the ferrules.
| పరామితి | విలువ |
|---|---|
| వర్తింపు / test standards | IEC 61754, Telcordia GR-326-CORE Class R, IEC 61300 తరగతి U |
| చొప్పించడం నష్టం (విలక్షణమైనది) | ≤ 0.2 dB standard connector; ≤ 0.35 dB low-loss MPO; down to 0.15 dB with imported ferrules |
| రిటర్న్ నష్టం | PC ≥ 40 dB, UPC ≥ 50 dB, APC ≥ 55 dB |
| Mating durability | ఎస్సీ / LC / FC ≥ 1,000 చక్రాలు; MPO ≥ 500 చక్రాలు |
| ఆపరేటింగ్ ఉష్ణోగ్రత | −40 to +85 °C for outdoor / జలనిరోధిత; −20 to +60 °C for indoor standard |
| Waterproof rating (outdoor connectors) | IP67 / IP68 |
| Ferrule materials | Zirconia ceramic (default Sanhuan; Sumitomo on request); precision-molded polymer with pin alignment (MPO) |
| Housing materials | Standard plastic (ఇండోర్); PEI or PDLC engineering plastic (బాహ్య / జలనిరోధిత) |


Standard SC / LC / FC / ST adapters and connectors ship from stock without a strict MOQ — sample and trial orders are welcome. MPO కనెక్టర్లు సాధారణంగా ప్రారంభమవుతాయి 100 యూనిట్లు. జలనిరోధిత మరియు టెలికాం-అనుకూల కనెక్టర్లు (Huawei / ZTE / Ericsson) హౌసింగ్ స్పెక్ని బట్టి ఒక్కో ప్రాజెక్ట్కి కోట్ చేయబడతాయి.
ఎ కనెక్టర్ ఫైబర్ కేబుల్ చివర ఉన్న ప్లగ్ - ఇది ఫెర్రుల్ను కలిగి ఉంటుంది మరియు ఫైబర్ను అంతం చేస్తుంది. ఒక అడాప్టర్ (also called coupler or mating sleeve) రెండు కనెక్టర్లను ముఖాముఖిగా కలిపే నిష్క్రియ జంక్షన్, తక్కువ-నష్టం సిగ్నల్ బదిలీ కోసం వారి ఫెర్రూల్లను సమలేఖనం చేయడం. ప్రతి ODF, ప్యాచ్ ప్యానెల్ లేదా వాల్ ప్లేట్ ప్యాచ్ కార్డ్లు లేదా పిగ్టెయిల్స్ నుండి ఇన్కమింగ్ కనెక్టర్లను స్వీకరించడానికి అడాప్టర్లను ఉపయోగిస్తుంది.
ఉపయోగించండి APC (green connector, 8° కోణ పోలిష్) ఏదైనా PON కోసం / FTTH వెలుపల మొక్కల లింక్, CATV RF-over-glass, మరియు DWDM — ఎక్కడైనా ప్రతిబింబించే కాంతి సిగ్నల్తో జోక్యం చేసుకోవచ్చు. ఉపయోగించండి UPC (blue connector) డేటా సెంటర్లలో ప్రామాణిక డేటా ట్రాఫిక్ కోసం, ఎంటర్ప్రైజ్ నెట్వర్క్లు మరియు చాలా ఇండోర్ కేబులింగ్. Never mate UPC to APC — the angle mismatch causes major loss and can damage the ferrules.
అవును. మేము తయారు చేస్తాము IP67 and IP68 waterproof connectors in PDLC and PEI housings, compatible with Huawei, ZTE, Ericsson and other major telecom equipment vendors. Please specify the target equipment model at RFQ stage so we can confirm the correct housing and interface spec.
అవును. Every shipment includes 100% factory test results (end-face, చొప్పించడం నష్టం, తిరిగి నష్టం). Electronic test reports in FLUKE or EXFO format are available on request — useful for project acceptance and customer audit.
అవును, we manufacture a full line of field-assembly connectors — threaded self-locking, alligator-mouth, drawer-type, CCTC single-ceramic, three-ring double-ceramic and more. See our dedicated Fast Connector category for the full range and specifications.
మేము లోపల స్పందిస్తాము 12 గంటలు, దయచేసి ప్రత్యయం ఉన్న ఇమెయిల్పై శ్రద్ధ వహించండి “@fibconet.com”.
అలాగే, మీరు వెళ్ళవచ్చు సంప్రదింపు పేజీ, ఇది మరింత వివరణాత్మక ఫారమ్ను అందిస్తుంది.