Fibconet manufactures 12 series of outdoor fiber distribution boxes for FTTH last-mile deployment. In the industry these are also called కొవ్వు (ఫైబర్ యాక్సెస్ టెర్మినల్), FDB, లేదా ఫైబర్ ముగింపు పెట్టె. Two families cover the two roles in a PON tree — Subscriber Boxes ముగించు 4 కు 24 drop-cable ports at pole, wall or building entry, మరియు Hub Boxes concentrate 1×8 or 1×16 splitting upstream of the subscriber layer.
Housings are ultrasonic-welded PC alloy or PC+ABS with V0 flame rating, qualified to IK09 impact and IP66 or IP68 sealing. Our factory keeps a rolling stock of 1,000 pcs on regular models, ships bulk orders under 5,000 pcs in about 15 రోజులు, and supports OEM color, లోగో, port layout and CAD drawings from an MOQ of 1,000 pcs. Products currently ship into ISP and EPC contractor projects in Brazil, Chile, Indonesia and Malaysia.

The sections below list the 12 models grouped by role, then cover the Sub-vs-Hub selection logic, technical parameters, manufacturing capability, packaging and OEM options, ఎఫ్ ఎ క్యూ, and a quotation channel.
Installed at the last drop point of an FTTH network. Each port terminates one drop cable running to a subscriber ONT. Typical wall-mount or pole-mount deployment.
| మోడల్ | ఓడరేవులు | హౌసింగ్ | సీలింగ్ | Typical Use |
|---|---|---|---|---|
| 4 Core PLC/SC Adapter Distribution Box | 4 | అబ్స్ | IP65 | Small building or MDU riser |
| Customized IP65 ABS Mini Distribution Box | 4–8 (అనుకూలీకరించదగిన) | అబ్స్ | IP65 | Rural low-density drops |
| 8-Port FTTH Distribution Enclosure | 8 | ABS/PC | IP65 | Standard FTTH terminal box for pole or wall |
| Plug-and-Play FTTH Terminal Box (Outdoor 5G) | 8–16 | PC మిశ్రమం | IP68 | Small-cell backhaul, pre-connectorized drops |
| Waterproof IP68 1-in / 8-out Terminal Junction Box | 1 లో / 8 బయటకు | PC మిశ్రమం | IP68 | స్ప్లైస్ ట్రే + cable management for pole-mount |
| FTTA Waterproof IP68 ABS/PC Termination Box | 8–16 | ABS+PC | IP68 | Base-station FTTA jumper aggregation |
| FTTH ABS/PC Distribution Box for Fiber Splicing | 12–16 | ABS+PC | IP65 | Mid-span splice + drop-cable termination |
| Anti-UV 16-Port PC+ABS Distribution Box | 16 | PC+ABS (UV stabilised) | IP66 | Long-term direct-sun exposure in tropical climate |
| FAT 18-Port Pre-connectorized Distribution Box | 18 | PC+ABS | IP66 | Fast deployment, pre-terminated drop pigtails |
| IP65 Strengthened ABS 24-Core Distribution Box | 24 | Reinforced ABS | IP65 | High-density MDU or curb-side aggregation |

Installed one layer above the Subscriber Box in the PON tree. Houses one or two 1×8 or 1×16 PLC splitters and distributes downstream over drop cables to the subscriber layer.
| మోడల్ | స్ప్లిటర్ కెపాసిటీ | హౌసింగ్ | సీలింగ్ | Typical Use |
|---|---|---|---|---|
| IP67 అవుట్డోర్ ఎన్క్లోజర్ వాటర్ప్రూఫ్ జంక్షన్ బాక్స్ | 1 స్ప్లిటర్ | PC మిశ్రమం | IP67 | Aerial or wall-mount trunk junction |
| FTTx Fiber Splitter Distribution Box for Network | 1–2 splitters | PC+ABS | IP66 | PON hub for street or block-level FTTH |
A PON access network has two enclosures between the OLT and the subscriber. Confusing them is the single most common cause of over- or under-buying.
| Hub Box (upper layer) | Subscriber Box (lower layer) | |
|---|---|---|
| స్థానం | Between feeder cable and drop cables | At the drop point closest to homes |
| Contains | PLC స్ప్లిటర్(లు), స్ప్లైస్ ట్రే, అడాప్టర్లు | అడాప్టర్లు, sometimes a small splitter, స్ప్లైస్ ట్రే |
| కెపాసిటీ | 1×8 or 1×16 splitting, వరకు 32 drops downstream | 4, 8, 16, 18 లేదా 24 subscriber ports |
| Typical sealing | IP66 (splash + tropical rain) | IP65 to IP68 (per exposure level) |
| Cable in | Feeder 5–6 mm round outdoor cable | 2×3 or 2×5 drop wire, 5 mm రౌండ్ కేబుల్ |
| Deployment ratio | 1 hub per 8–16 subscriber boxes | 1 sub box per building or per pole |
| Port count | Subscriber density | Common deployment |
|---|---|---|
| 4 ఓడరేవులు | Small building, single-family clusters | Wall-mount inside home entrance, rural drop |
| 8 ఓడరేవులు | Standard FTTH street node | Pole-mount, wall-mount at building entry |
| 16 ఓడరేవులు | Mid-density MDU or curb-side | Wall-mount inside building risers |
| 18 ఓడరేవులు | Pre-connectorized rapid deploy | Plug-and-play kits with pre-terminated pigtails |
| 24 ఓడరేవులు | High-density MDU or aggregation node | Basement or riser cabinet |
| పరామితి | Subscriber Box family | Hub Box family |
|---|---|---|
| హౌసింగ్ మెటీరియల్ | అబ్స్, ABS+PC or PC alloy | PC+ABS alloy (UV-stabilised) |
| Housing thickness | 2.3 mm typical | 2.3 mm typical |
| Flame rating | UL94 V0 | UL94 V0 |
| Sealing grade | IP65 / IP67 / IP68 (per model) | IP66 / IP67 (per model) |
| Impact resistance | IK09 | IK09 |
| సీలింగ్ పద్ధతి | Ultrasonic welding on IP68 models | Stepped waterproof pressure block + independent rubber plugs |
| Latch hardware | 304 stainless steel on outdoor models | 304 స్టెయిన్లెస్ స్టీల్ |
| కేబుల్ ప్రవేశం | 2×3 mm or 2×5 mm drop wire, 5 mm రౌండ్ | Zoned drop-cable port + feeder-cable port |
| Splitter capacity | None or 1×8 / 1×9 optional | 1 కు 2 PLC స్ప్లిటర్లు (1×8 or 1×16) |
| Adapter interface | ఎస్సీ, LC, compatible with Huawei / కార్నింగ్ / Fiberhome housings | Same |
| ఆపరేటింగ్ ఉష్ణోగ్రత | −40°C to +65°C | −40°C to +65°C |
| Field service life | 15 years outdoor with UV additive package | 15 years outdoor with UV additive package |
| Mounting | Wall-mount + pole-mount hardware included | Wall-mount + pole-mount hardware included |
గమనిక: values above are family-typical, not a single-SKU datasheet. Ask us for the specific test report of the model you are quoting; we send it under the model part number.
Fibconet’s parent operation in optical passive components dates back to 1994. FAT box production runs on dedicated injection molding and ultrasonic welding lines; housings are molded in-house from qualified PC and PC+ABS resins so batch-to-batch dimensional consistency stays under control. UV stabiliser and weathering-modifier additive packages are dosed to the resin at the pre-mix stage — that is what supports the 15-year outdoor field life claim.
Raw material RoHS reports are supplied by default with every shipment. Fibconet operates under an ISO 9001 quality management system. Additional certifications — REACH, ఈ, UL94 V0 for the resin, third-party IP grade test reports — are issued per model and per project requirement. Send us your target market and the model list; we return the applicable certificate set with the quotation.
| Port count | Inner box | Master carton | కార్టన్ పరిమాణం (సెం.మీ) | స్థూల బరువు |
|---|---|---|---|---|
| 4 కోర్ | 1 unit per inner box | 50 యూనిట్లు | 40 × 29 × 58 | 16 కిలొగ్రామ్ |
| 8 కోర్ | 1 unit per inner box | 20 యూనిట్లు | 52 × 32 × 42 | 14 కిలొగ్రామ్ |
| 16 కోర్ | 1 unit per inner box | 10 యూనిట్లు | 60.5 × 33.5 × 50 | 15.3 కిలొగ్రామ్ |
The Hub Box sits upstream, holds the 1×8 or 1×16 PLC splitter and feeds several downstream Subscriber Boxes. The Subscriber Box sits at the drop point closest to homes and terminates 4 కు 24 డ్రాప్ కేబుల్స్. A typical PON tree runs one Hub Box per 8–16 Subscriber Boxes.
Ask for IP68 with ultrasonic welding for splash-heavy or immersion-prone junctions, and PC+ABS alloy with UV additive package plus 304 stainless-steel latch hardware for salt-spray tolerance. Screw-sealed IP65 boxes are fine indoors but not on coastal poles.
Panels are drilled and tooled to the mainstream footprints — Huawei, Corning and Fiberhome. Send us your target adapter model at RFQ stage; if it is a proprietary housing we confirm feasibility before quoting.
MOQ for custom configuration is 1,000 pcs. For a trial or sample run, we can pull from the rolling 1,000-piece stock of regular models and ship smaller quantities. Ask us about sample delivery when you send the RFQ.
Standard-configuration orders under 5,000 pcs ship in about 15 రోజులు; there is no difference between peak and off-peak seasons. అనుకూల రంగు, logo or port layout adds about 10–14 days. Confirm the actual date on the pro-forma invoice.
అవును. After order confirmation, we send CAD drawings and an installation manual per model. A short installation video is also available for wall-mount and pole-mount configurations.
Modified PC+ABS alloy with a UV stabiliser and weathering-modifier additive package supports about 15 years of outdoor service without cracking, weathering or powdering, within the −40°C to +65°C operating range.
Existing models are not field-expandable. If your project needs an expandable design, we can develop a custom housing from your specification; the development plus tooling cycle is quoted separately.
Raw material RoHS reports are supplied by default. REACH, ఈ, UL94 V0 resin certification and third-party IP grade test reports are provided on request; if you need a certificate we do not yet hold, we can arrange third-party testing at project scale.
Overall factory defect rate is below 0.5%. Post-delivery rework rate is below 0.2%, and that number includes damage from on-site handling — so the true product-only rework rate is lower. Batch inspection records are available on request for tender projects.
Three ways to get a quote and technical support:
మేము లోపల స్పందిస్తాము 12 గంటలు, దయచేసి ప్రత్యయం ఉన్న ఇమెయిల్పై శ్రద్ధ వహించండి “@fibconet.com”.
అలాగే, మీరు వెళ్ళవచ్చు సంప్రదింపు పేజీ, ఇది మరింత వివరణాత్మక ఫారమ్ను అందిస్తుంది.