ویرایش ترجمه
جستجو کردن

کابل فیبر نوری

Fiber Optic Cable Manufacturer — GYTS, GYTA, ADSS, ASU, رها کردن, Air-Blown Micro & Submarine Cable

FIBCONET has manufactured fiber optic cable in China for 12 سال ها, running dedicated automated lines for stranded loose-tube, central-tube, self-supporting, air-blown micro and submarine cable series.

Combined output on our mainstream armored lines (GYTS / GYTA) reaches tens of millions of fiber-kilometers per year, with stock inventory maintained across 4–288-core standard configurations.

fiber optic cable structure

Every drum ships after 100% factory testing — attenuation, کششی, water penetration and end-of-drum OTDR trace — against IEC 60794 سری and other applicable standards. Our submarine cable also complies with GB/T 18480, ITU-T G.976 and GJB 4489 military-grade specifications.

Below are the twelve cable series currently shipping to telecom operators, engineering contractors, power utilities and FTTH integrators across Southeast Asia, خاورمیانه, Latin America and Europe. Each product page carries fiber count options, connector-ready pre-termination, and full mechanical / environmental specifications.

Fiber Optic Cable Series We Manufacture

نوع کابل مدل استقرار Max Fiber Count Key Highlight
Stranded Loose Tube, Steel-Tape Armored GYTS مجرا, هوایی 288 الیاف Long-term tensile 600 ن; crush 300 N/100 mm; 20-year jacket life
Stranded Loose Tube, Aluminum-Tape Armored GYTA مجرا, هوایی (PE conduit for direct burial) 288 الیاف Anti-rodent, moisture-blocking, EMI-shielding; UV-additive option extends life +5 سال ها
Central Loose Tube, Non-Metallic GYXTY / GYFXY (FRP-reinforced) هوایی, مجرای, lightning-prone regions 24 الیاف سبک وزن, all-dielectric; jacket down to 1.1 میلی متر; 10,000 کیلومتر / month output
خود پشتیبانی تمام دی الکتریک (ADSS), Single-Jacket ADSS Single-Jacket هوایی, power-line corridors, تا 300 متر 144 الیاف Aramid strength member; PE jacket 1.8 mm ± 0.1 میلی متر; 25–40% lower cost than double-jacket
ADSS, Double-Jacket ADSS Double-Jacket Aerial in coastal salt-fog, icing, long-span installations 288 (تا 576 custom) 10–15 years extended service life vs single-jacket; 720 h salt-spray tested; UV per GB/T 18899-2023
Aerial Self-Supporting (ASU) ASU / GYFXY-lightweight Short-span aerial & duct dual use, تا 120 متر دهانه 24 الیاف 3,000 h UV without cracking; 15-year warranty with 1:1 defect replacement; lower cost than ADSS
Figure-8 Central-Tube GYXTC8S Aerial with integral messenger, تا 100 متر دهانه 96 الیاف 7×1.2 galvanized steel strand messenger, 5 kN tensile; 30-year UV per IEC 60794-1
Air-Blown Micro Cable GCYFY / GCYFXY Microduct systems 144 الیاف (stranded); 24 الیاف (central-tube) Outer diameter from 1.8 میلی متر; grooved jacket for extended blowing distance; HDPE or LSZH
FTTH Drop Cable, Bow-Type Self-Supporting ГХХЧЧ FTTH outdoor drop with steel or FRP messenger 1–4 fibers G.657.A2 default; steel-wire or non-metallic (FRP) messenger; LSZH / بر / ژاکت پی وی سی
FTTH Drop Cable, Indoor Bow-Type GJXH FTTH indoor drop, بلند شدن 1–4 fibers LSZH jacket standard; G.657.A2 bend-insensitive fiber
کابل توزیع داخلی GJFJV / tight-buffer Building risers, indoor cabling, patch cord raw stock 2–24 fibers 5 production lines × 180 km/day; long-term tensile 200 ن (2.0 میلی متر); operating −20 to +70 درجه سانتی گراد
Submarine Cable GYTA33 & deep-water armored Coastal, island interconnect, سکوهای فراساحلی, اعماق آب تا 8,000 متر 288 الیاف 100 Gb/s بازه تکرار نشده تا 500 کیلومتر; long-term tensile 4 kN, کوتاه مدت 10 kN; 25-سال عمر طراحی; GB/T را ملاقات می کند 18480, IEC 60794, ITU-T G.976 and GJB 4489

OPGW (سیم زمین نوری) و کابل کامپوزیت فوتوالکتریک نیز بخشی از خط تولید ما برای استقرار برق است - صفحه محصول OPGW را برای گزینه‌های ساختاری و رتبه‌بندی جریان اتصال کوتاه ببینید..

سری کابل فیبر نوری

نحوه انتخاب کابل فیبر نوری مناسب

سه سوال تعیین کننده کابل مناسب برای یک پروژه است: جایی که نصب شده است, چه تعداد الیاف حمل می کند, و چه مکانیکی / بارهای محیطی که با آن مواجه است.

1. کابل را با محیط استقرار مطابقت دهید

محیط استقرار سری پیشنهادی چرا
مجرا / مجرا (صندوق عقب استاندارد مخابرات) GYTS یا GYTA زره پوش, کشش بالا, 20-سال عمر مفید
هوایی, منطقه مستعد رعد و برق محدود / GYXTY (غیر فلزی) یا ADSS تمام دی الکتریک از آسیب صاعقه جلوگیری می کند
آنتن در امتداد خطوط برق (دهانه می کند > 100 متر) ADSS Single-Jacket (معتدل) یا ژاکت دو نفره (ساحلی / icing) خود حمایتی تا 300 متر; استحکام نخ آرامید
دفن مستقیم GYTA53 (کت دو نفره + زره نواری فولادی) یا GYTA + PE conduit Rodent, crush and moisture protection
Microduct (existing or new) Air-Blown Micro Cable (GCYFY / GCYFXY) 1.8 mm minimum diameter, groove jacket for blow distance
Short-span aerial + duct dual-use ASU Cheaper than ADSS, higher tensile than standard drop cable
Aerial with integral messenger, mid-span Figure-8 GYXTC8S Built-in steel messenger, 5 kN tensile, 100 متر دهانه
FTTH outdoor drop GJYXCH bow-type self-supporting Steel or FRP messenger; G.657.A2 bend-insensitive fiber
FTTH indoor drop / بلند شدن GJXH indoor bow-type LSZH jacket for building fire code
Coastal, island interconnect, فراساحلی Submarine cable (GYTA33 series) HDPE jacket, galvanized or Zn-Al armored steel wires
Power utility ground wire OPGW Composite power ground + کابل نوری

2. Calculate the Fiber Count You Need

A working formula: total equipment ports × 2, plus a 10–20% spare buffer. For serial-multiplexed devices the count can be lower. Standard fiber counts we stock: 2, 4, 6, 8, 12, 24, 48, 96, 144, 288. Non-standard counts including 576-core (ژاکت دو نفره ADSS) در صورت درخواست در دسترس هستند.

3. Match Jacket and Armor to the Load Profile

  • Standard PE — general outdoor, 20-سال عمر مفید
  • UV-additive PE - عمر در فضای باز را تا 5 سال برای مناطق پرخورشید افزایش می دهد
  • AT (ضد ردیابی) بر - برای ADSS نصب شده در نزدیکی خطوط ولتاژ بالا برای مقاومت در برابر خوردگی الکتریکی
  • LSZH - هالوژن کم دود صفر برای تونل ها, متروها, مراکز داده و رایزر داخلی
  • HDPE - زیردریایی, محیط های پر فشار و خرد شدن
  • زره نواری فولادی (GYTS) - حفاظت از جوندگان, مرطوب, محافظ EMI
  • زره نوار آلومینیومی (GYTA) - حفاظت معادل, وزن کمتر, در برخی از محیط های خورنده بهتر است
  • 316زره L از فولاد ضد زنگ - ساحلی / ارتقاء دریایی برای پیام رسان figure-8; Zn-Al روکش شده برای خوردگی

GYTS در مقابل GYTA در مقابل ADSS - مقایسه سریع برای کابل کشی Trunk Telecom

GYTS GYTA ADSS
زره نوار فولادی راه راه نوار آلومینیومی راه راه هیچ کدام (all-dielectric)
عضو قدرت سیم فولادی (FRP برای مناطق رعد و برق) سیم فولادی نخ آرامید
محدودیت فاصله هوایی 80 متر 80 متر تا 300 متر
دفن مستقیم لوله پلی اتیلن توصیه می شود لوله پلی اتیلن اجباری قابل اجرا نیست
بهترین برای مجرای استاندارد / هوایی, خطر جوندگان بالا GYTS هم همینطور, وزن کمتر آنتن بلند در امتداد تیرهای برق

Technical Specifications Across Trunk Cable Series

پارامتر مقدار
Fiber grade (پیش فرض) G.652.D (در باره 90% of shipments); G.657.A1, G.657.A2, G.654.E and OM3 / OM4 / OM5 on request
تضعیف @ 1310 نانومتر ≤ 0.35 دسی بل در کیلومتر
تضعیف @ 1550 نانومتر ≤ 0.21 دسی بل در کیلومتر
Fiber count range 2 – 288 cores standard; تا 576 cores custom (ژاکت دو نفره ADSS)
حداقل شعاع خمش ≥ 10× cable diameter (استاتیک); ≥ 20× diameter (پویا)
Long-term tensile strength GYTS/GYTA 600 ن; شکل-8 5 kN; Submarine 4 kN long-term / 10 kN installation
مقاومت در برابر خرد شدن ≥ 300 N/100 mm (armored series)
دمای عملیاتی -40 تا +70 درجه سانتی گراد (در فضای باز); -20 تا +70 درجه سانتی گراد (indoor LSZH / پی وی سی)
Design service life Outdoor armored 20 سال ها; ADSS double-jacket 25–30 years; زیردریایی 25 سال ها
آزمایش کردن 100% drum-by-drum attenuation test; OTDR trace archived per drum

Submarine Cable — Our Deep-Water Line ⭐

Our submarine cable line targets short-haul unrepeated systems — island interconnect, offshore platform tie-in, coastal loops — where a single-span 100 Gb/s link up to 500 کیلومتر eliminates the cost of subsea repeaters, power feed and maintenance.

  • Depth rating: standard shallow-water build for up to 100 متر (most common); deep-water build rated up to 8,000 متر
  • تعداد فیبر: تا 288 الیاف
  • زره: shallow-water uses hot-dip galvanized low-carbon round steel wire; deep-water uses high-carbon high-tensile round steel wire with zinc-aluminum alloy coating
  • ژاکت: HDPE for seawater corrosion, water blocking and pressure resistance
  • Tensile: بلند مدت 4 kN, short-term installation 10 kN
  • رعایت استانداردها: GB/T 18480, IEC 60794, ITU-T G.976, GJB 4489
  • Design service life: نه کمتر از 25 سال ها
  • Installation methods: trench burial (flat silt/sand seabed), surface laying (calm water), casing protection (rocky/reef zones), underwater suspension (bay spans)

Manufacturing Capability

Automated Production Lines with Inline Inspection

Our GYTS / GYTA lines run imported cabling machines, high-speed secondary coating equipment, and dual-layer co-extrusion jacket lines. Inline laser concentricity gauges and real-time OTDR scanners monitor every step. A three-stage water-blocking process controls excess fiber length, tape thermal bonding and jacket extrusion parameters through digital process control.

Annual Output & Stock Position

  • GYTS / GYTA: tens of millions of fiber-kilometers per year across all core counts, with 4–288-core standard configurations kept in stock
  • GYXTY: ~10,000 km per month
  • Indoor distribution cable: 5 production lines × 180 km per line per day
  • ADSS Single-Jacket: 12–48-core kept in stock; MOQ 1 کیلومتر
  • ASU: 2–24-core standard in stock; same-day shipping for regular configurations
  • شکل-8: 2–48-core in stock across 4 dedicated extrusion lines

100% Drum-by-Drum Testing

  • Attenuation test on every drum before shipment — not sampling
  • Length tolerance strictly controlled within +1 به +2 metres per drum
  • Per-drum OTDR trace archived and provided to buyer on request
  • Tensile, water-penetration and aging test reports available under IEC 60794 methodology

Container Loading & بسته بندی

Standard drum length is 1–3 km per wooden reel for most trunk series; custom drum lengths supported on request. Approximate cable-length loading per container for figure-8 and similar profiles:

  • 20 GP container: 800 – 1,200 km of cable
  • 40 مقر container: 1,900 – 2,800 km of cable

Actual loading depends on cable diameter, drum size and stacking configuration — our sales team will calculate exact quantities against your PO.

گواهینامه ها و انطباق

  • ISO 9001 سیستم مدیریت کیفیت, در سطح کارخانه
  • IEC 60794 series — optical cable performance, environmental and mechanical test methods
  • این — European conformity for applicable product lines
  • را / ETL — available for North American market entry
  • CPR — European Construction Products Regulation, for cables installed in permanent buildings
  • RoHS — hazardous substance compliance; certificates renewed annually
  • Submarine cable additionally complies with GB/T 18480, ITU-T G.976 and GJB 4489

کاربرد گواهینامه بسته به خط محصول و بازار مقصد متفاوت است. لطفاً کشور مورد نظر را تأیید کنید, محیط استقرار و استانداردهای مورد نیاز هنگام درخواست قیمت.

Frequently Asked Questions About Fiber Optic Cable Sourcing

Q1. حداقل مقدار سفارش شما چقدر است?

Standard trunk cable MOQ is 1 کیلومتر. Indoor distribution cable also 1 km MOQ; custom-colour indoor cable requires 5 کیلومتر. Submarine cable typically starts at 100 km due to the specialized production line setup. Bow-type drop cable ships from standard stock.

Q2. زمان تحویل استاندارد چقدر است?

Regular 2–48-core GYTS / GYTA / GYXTY / ASU configurations ship from stock within days. Custom fiber counts, lengths or non-standard jackets: typically 15–25 working days depending on drum count. Submarine cable and 288-core+ builds require project-specific scheduling.

Q3. Which fiber grade do you use as default?

در باره 90% of our finished cable ships with G.652.D single-mode fiber. G.657.A1 and G.657.A2 bend-insensitive grades are our default for drop cable and tight-space installations. G.654.E for long-haul 400G+ backbone and OM3 / OM4 / OM5 multimode for data-centre indoor cable are available on request.

Q4. Can you provide OTDR traces and test reports per drum?

آره. Every drum ships after 100% attenuation testing, with the OTDR trace archived. Written test reports covering tensile, water penetration and thermal aging are available under IEC 60794 methodology on request — useful for project acceptance and customs clearance.

Q5. Can you customize drum length, colour and marking?

آره. Standard drums are 1–3 km; longer runs supported on request (به عنوان مثال. ADSS in 500 متر, 1200 m or segmented lengths). Jacket colour customization has a 5 km MOQ. Sequential metre marking, batch code and buyer logo can be printed to your specification.

پرسش

Q6. What certifications can you supply for European and North American markets?

Our cable ships with ISO 9001, این, RoHS and IEC 60794 compliance as standard. را / ETL certifications are supported for North American entry; CPR is available for cable installed in permanent European buildings. Third-party test reports and country-specific certification can be arranged per project.

Q7. How do I choose between GYTS, GYTA, محدود, ADSS and ASU?

Short answer: استفاده کنید GYTS یا GYTA for standard duct / aerial trunk cabling; محدود when a non-metallic (unarmored) cable is required; کاپشن تک ADSS for aerial spans up to 300 m in temperate conditions, کت دو نفره for coastal salt-fog or ice-loaded spans; ASU for short-span aerial + duct dual-use where you want the strength of ADSS without the cost. Detailed matrix above.

Q8. Do you supply cables suitable for direct burial?

For direct burial we recommend GYTA53 (double-jacket with steel-tape armor) or GYTA with an additional PE protective conduit. Standard single-jacket ASU and ADSS are not designed for direct burial — the buried environment will corrode the jacket over time.

Q9. What is the warranty and service life?

گارانتی استاندارد کارخانه است 1 سال. Design service life: 20 years for standard outdoor armored cable; 25–30 years for ADSS double-jacket and submarine cable; 15 years for ASU with 1:1 defect replacement if the failure is traced to manufacturing.

Q10. How much cable fits in a shipping container?

For figure-8 and similar profiles: آ 20 GP container carries approximately 800–1,200 km of cable; آ 40 HQ carries 1,900–2,800 km. Exact loading varies with cable OD, drum size and stacking. Provide us the drum spec and we’ll calculate loading before the PO is placed.

یک نقل قول سریع دریافت کنید

ما در داخل پاسخ خواهیم داد 12 ساعت ها, لطفا به ایمیل با پسوند توجه کنید "@fibconet.com".

همچنین, می توانید به صفحه تماس, که فرم دقیق تری ارائه می دهد.