MPO / MTP Data Center Cabling Manufacturer — Cassettes, Patch Panels, Trunk Cables and Patch Cords
Hana ʻo Fibconet 10 series of MPO / MTP fiber optic products for 40G, 100ʻO G, 400G and 800G data center cabling. The product line covers cassette modules, 1U rack patch panels, MPO trunk and patch cords, MPO-to-LC breakouts, loopbacks and MPO/MTP cleaners — enough to build a full high-density link from the MDA to the switch port without adding a second supplier.
Production runs on dedicated MPO polishing, ribbon splicing and 3D interferometer inspection lines. Monthly output reaches 150,000 ʻāpana across the MPO family. Fiber count scales up to 72 fibers per MPO end for 400G/800G backbone applications. Single-fiber insertion loss can be controlled to 0.15 dB on assemblies built with Japanese-imported ferrules, and to typical 0.20–0.35 dB on standard builds with domestic Sanhuan ferrules.
Every finished cable is 100% inspected for insertion loss, Hoʻi i ka pohala, end-face geometry, polarity, kaʻina fiber, ka lōʻihi a me ka helehelena. FLUKE / EXFO electronic test reports are available after order confirmation. Products currently ship into hyperscale, telecom and enterprise data-center projects in the US, Canada, Germany, UK and Netherlands.
10 MPO / MTP Products We Manufacture
Pūʻulu 1 — Cassette Modules
Pre-terminated MPO-to-LC or MPO-to-MPO conversion cassettes for 1U rack panels. The building block of any high-density data-center row.
Hoʻohālike
Helu Uila
Interface
Hoʻohana maʻamau
Fiber Optic MPO 1U 12–144 Cores Cassette Module
12 i 144
MPO trunk in / LC duplex out
Standard MDA-to-EDA conversion
12/24 Core kiʻekiʻe-density solution mpo cassette module
12 a i ʻole 24
MPO in / LC out
Compact rack builds with 12F or 24F MPO base
8/12/24 Mpo mtp base i 24 LC Ultra Highs density 1u Modular
A hiki i 24 LC per 1U
MPO/MTP in / 24 LC out
Highest 1U density; AI cluster and hyperscale rows
Pūʻulu 2 — Rack Patch Panels
Empty or pre-assembled 1U 19-inch chassis to hold cassette modules and to organise trunk cables at the top of the rack.
Hoʻohālike
Rack Size
Loading
Hoʻohana maʻamau
Data Center 19-inch Standard Rack MPO Patch Panel
1U
Empty chassis for cassettes
Standard MDA rack, modular build
Pre-assembled 1U 19-inch Rack LC MTP®/MPO Patch Panel
1U
Pre-terminated LC front, MPO back
Plug-and-play rack, no field assembly
Pūʻulu 3 — Patch Cords and Trunk Cables
The physical link between MPO cassettes, nā papa hoʻopili, transceivers and MPO backbone runs.
Hoʻohālike
Kapili
Fiber Options
Hoʻohana maʻamau
Factory Pre-termination MPO-MPO 3.0mm LSZH Patch Cord / Trunk Cable
MPO to MPO
OS2 / OM3 / OM4 / OM5
Backbone trunk, MDA to EDA
Fiber Optic MPO MTP Hoʻohui Patch Cord
MPO to MPO
OS2 / OM3 / OM4 / OM5
Rack-to-rack short jumper
FTTA MPO/MTP Fiber Optic Patch Cord Cable
MPO to MPO, outdoor jacket
OS2 / OM3 / OM4
Base station FTTA and outdoor short link
Pūʻulu 4 — Loopback
Used to test transceiver ports, cassette continuity and rack integrity without pulling a full trunk link.
Hoʻohālike
Interface
ʻO ka fiber
Hoʻohana maʻamau
OM3 MM MTP/APC Female MPO Loopback
MTP/APC female
Om3 multimode
Multimode transceiver and cassette test
Pūʻulu 5 — Cleaning Tools
End-face contamination is the single largest cause of MPO insertion-loss failures. One qualified cleaner per rack is standard project practice.
Hoʻohālike
Kupono
Hoʻohana maʻamau
ʻO nāʻano āpau āpau e hoʻopili ai i ka mpo / mtp maʻemaʻe
All MPO/MTP end-faces
Field cleaning before mating; commissioning kit
What Is MPO / MTP and How to Choose the Right Product
MPO vs MTP — Same Standard, Different Brand
MPO (Pākuʻi nui-fiber) is the generic multi-fiber connector standard defined in IEC 61754-7. MTP® is US Conec’s brand-name implementation of the same MPO standard, with tighter mechanical tolerances on the guide-pin holder, spring load and internal ribbon protection. Both mate with each other and both follow the same fiber count and polarity rules. Fibconet manufactures to the MPO standard and supplies MTP-compatible builds on request; the underlying optical spec is identical.
Polarity — Type A, ʻAno B, Type c
Polarity
Fiber Sequence
Hoʻohana maʻamau
ʻAno A (Straight)
1↔1, 2↔2 … 12↔12 straight-through
Point-to-point trunks with A-to-B duplex crossover in the patch cord
ʻAno B (Reverse)
1↔12, 2↔11 … 12↔1 fully reversed
Direct connection to SFP+ / QSFP transceivers; most common for 40G/100G breakout
Type c (Pair-swap)
Adjacent pairs swapped: (1↔2, 2↔1), (3↔4, 4↔3) …
Legacy pair-flip cabling
Polarity errors are the single most common cause of link-up failure on MPO systems. Confirm polarity at RFQ stage; we ship Type A / B / C per your bill of materials.
Gender — Male (with pins) vs Female (no pins)
Male: two guide pins protrude from the end-face. Used at fixed / patch-panel ends.
Female: no pins, two guide-pin holes only. Used at the equipment / movable-jumper end.
Wrong gender at RFQ = the entire batch has to be re-terminated. Always specify Male-Female, Female-Female or Male-Male at the quotation stage.
Fiber Type — Match to Data Rate and Distance
ʻO ka fiber
Loʻihi nalu
10G reach
40ʻO G / 100G reach
Hoʻohana maʻamau
Om3 multimode
850 nm
550 m
100 m / 100 m (SR4)
Short rack-to-rack, cost-sensitive builds
OM4 multimode
850 nm
550 m
150 m / 150 m (SR4)
Standard data-center backbone
OM5 multimode
850 & 953 nm SWDM
550 m
≥ 150 m; supports 400G SR4.2
AI cluster and next-gen supercompute backbone
OS2 singlemode
1310 / 1550 nm
10 km +
10 km + (LR4 / DR4)
Inter-building, pā kula, DCI long-haul
Insertion Loss Grade — Standard vs Low-Loss
Kumu
Max IL per mated pair
Hoʻihoʻi Nalo
Hoʻohana maʻamau
Kūlana (SM APC)
≤ 0.70 dB
≥ 55 dB
Enterprise LAN, standard data-center runs
Low-Loss / Elite (SM APC)
≤ 0.35 dB (maʻamau 0.25 dB)
≥ 55 dB
Cabinet-to-cabinet 100G high-density backbone
Ultra Low-Loss (Japanese ferrule)
0.15 dB per single fiber
≥ 55 dB
400ʻO G / 800G AI backbone; long link budgets
Kūlana (MM PC)
≤ 0.50 dB
≥ 20 dB
OM3/OM4 short data-center runs
Low-Loss (MM PC)
≤ 0.35 dB (maʻamau 0.20 dB)
≥ 20 dB
OM4/OM5 high-density backbone
Nā kiko pili Tech
Nānā: the values below are family-typical across the 10 moʻo, ʻaʻole kahi ʻikepili SKU hoʻokahi. E noi mai iā mākou no ka hōʻike hōʻike hoʻohālike kikoʻī ma ke kahua RFQ; hoʻouna mākou ma lalo o ka helu māhele kumu hoʻohālike.
ʻĀpana
Waiwai maʻamau
Manaʻo
Fiber count per MPO end
4 / 8 / 12 / 16 / 24 / 48 / 72
Standard 12F and 24F; 72F for 400G/800G AI backbone
ʻAno fiber
OS2 (G.652.D, G.657.A1/A2), OM3, OM4, OM5
G.657.A2 for tight-radius rack routing
Polarity
ʻAno A / ʻAno B / Type c
Type B is default for 40G/100G breakout
kāne kāne
Male (with pins) / Female (no pins)
Both ends selectable per port
End-face polish
APC (kū kūlele) / PC (multimode)
APC green, PC beige/aqua
poho hookomo (hoʻokahi fiber)
0.15 – 0.35 dB per grade
0.15 dB achievable with Japanese-imported ferrules
Hoʻihoʻi poho
≥ 55 dB (SM APC), ≥ 45 dB (SM PC), ≥ 20 dB (MM PC)
Ka lōʻihi o ka male ʻana
≥ 500 Nā Pāʻani Pūnaewele, IL drift ≤ 0.2 dB
Guide-pin positioning with elastic pre-load
ʻO ka'āpana liʻiliʻi loa
MPO end ≥ 30 mm; LC breakout end ≥ 20 mm
Kūʻokoʻa 15 mm, hoʻoikaika kino 30 mm on G.657.A2 fiber
Hana wela
−20°C to +60°C
Optical performance stable across the range
Ingress / kaulike
IP50; 45°C / 95% RH; 24-hour salt spray
Not for long-term unprotected outdoor use unless FTTA-jacketed
Length range
0.2 i 300 m custom; · Papa Hoʻolaha
· FTTH
· ʻO nā lako pūnaewele fiber-optic
· Uena TV uwea 0.5 i 30 m
Ma ke kumu hoʻohālike
Trunk cable OD
3.0 mm typical (8/12/16/24F); ~5.0 mm (48F)
Higher fiber count = larger OD
Kāleka
LSZH standard; OFNR / OFNP on request
Suitable for data hall, riser and plenum
Ka lōʻihi nalu
1310 / 1550 nm (SM), 850 / 1300 nm (MM)
Palapala hōʻoia
1 makahiki; design life up to 10 makahiki
Field replacement covered within warranty period
Ka Hana Hana a me ka Mana Mana
Production Line and Monthly Capacity
ʻO ka hana makua o Fibconet i nā ʻāpana passive optical e hoʻi mai ana 1994. Ko ke mpo / MTP line runs on dedicated equipment: automated fiber-separating jigs, sub-micron 3D polishing machines and integrated injection-molding stations for one-piece reinforcement at the breakout root instead of simple heat-shrink. Monthly output reaches 150,000 ʻāpana. Standard orders of several thousand pieces ship in 7–12 days; bulk orders above 20,000 pieces ship in 15–20 days.
Ka Mana Mea Upstream
An MPO patch cord is only as good as its ferrule, its fiber and its ribbon splice. Hoʻomalu mākou i ka hoʻopaʻa ʻana i luna ma mua o ka pae hui wale nō:
Fucrules: domestic Sanhuan ferrules on standard builds; Japanese-imported ferrules (Sumitomo class) on ultra-low-loss builds. Both selectable per order.
ʻO ka fiber: YOFC / Fiberhome / HTGD single-mode and OM3/OM4/OM5 multimode, with G.657.A2 bend-insensitive fiber for tight-radius rack routing.
ʻO ke kaula Aramid: Taihe standard; DuPont Kevlar available on request.
Jacket compound: LSZH low-smoke zero-halogen resin; OFNR and OFNP grades available.
Ribbon splicing: high-precision ribbon fiber fusion splicers, core-by-core alignment.
100% Nānā maikaʻi
Insertion loss and return loss: tested on every fiber of every finished cable with a dedicated IL/RL tester.
End-face geometry: 3D interferometer inspection; every finished ferrule end-face.
ʻO ka polarity a me ke kaʻina fiber: core-by-core verification against the bill of materials on every unit.
Length and appearance: mechanical measurement and visual inspection.
Batch environmental testing: high-low temperature cycling per batch.
Test reports: FLUKE / EXFO electronic reports available on request after order confirmation.
Nā palapala hōʻoia a me ka hoʻokō
Hoʻohana ʻo Fibconet ma lalo o kahi hoʻohui ISO 9001 / ISO 14001 / ISO 45001 ʻōnaehana hoʻokele e uhi ana i ka maikaʻi, kaiapuni a me ke olakino hana & palekana. Raw-material RoHS reports ship by default. Product-level compliance — CE, REACH, ka, ETL — is issued per model and per target market. ʻOkoʻa ka hoʻohana ʻana i ka palapala hōʻoia e ka huahana a me nā koi o ka papahana. E hoʻouna mai iā mākou i kāu mākeke pahuhopu a me ka papa inoa hoʻohālike; we return the applicable certificate set with the quotation.
Kōkele, ʻO OEM a me nā koho maʻamau
Standard Packaging
Each patch cord / trunk cable sealed in an individual PE bag.
Cassettes and patch panels foam-cushioned in an inner box.
Master export carton labeled with model, Ka nui, polarity and gender code.
ʻO OEM a me nā koho maʻamau
Ka lōʻihi: kekahi lōʻihi mai 0.2 m i ka 300 m, cut to your bill of materials.
Breakout leg length: individual breakout legs cut to differentiated lengths (length difference ≤ 30 knm) for staggered rack ports.
Breakout configuration: 24F to 2×12 / 3×8 / 4×6; 16F to 2×8; 48F to 6×8; a i 6 MPO connectors per single end on MPO-to-MPO breakouts.
Polarity: ʻAno A / B / C per port; internal crossover on Type B for direct SFP mating.
Ferrule grade: domestic Sanhuan or Japanese-imported per fiber-count / IL grade selection.
Jacket color: ka wai (OM3), erika violet (OM4), ʻōmaʻomaʻo lime (OM5), melemele (OS2), custom RAL.
Breakout root protection: ʻaʻohe (short runs), nylon boot (standard rack), braided sleeve (high-wear).
OEM label and printing: on connector body, PE bag and master carton.
Hoʻopili maʻamau: PE bag and carton design per your artwork, Moo 30,000 pcs for full custom packaging run.
Nā laʻana: free small-quantity samples for quality verification; only shipping cost payable, deductible from the first bulk order.
Nīnau pinepine
Q1. What is the difference between MPO and MTP®?
MPO is the generic IEC 61754-7 multi-fiber connector standard. MTP is US Conec’s brand-name implementation of the same standard with tighter mechanical tolerances on the guide-pin holder and internal ribbon protection. Both mate with each other. Fibconet manufactures to the MPO standard; MTP-compatible builds are available on request.
Q2. What is the highest data rate your MPO products support?
Up to 800G. The product line supports 40G, 100ʻO G, 400G and 800G stably. For 400G / 800G AI-backbone applications we recommend 24-fiber or 72-fiber MPO with the ultra-low-loss ferrule grade to preserve link budget.
Q3. What is the maximum fiber count per MPO end?
72 fibers per single MPO end. Standard 12F and 24F cover most 40G / 100ʻO G / 400G rack builds; 72F is used for 400G / 800G high-density AI backbone and supercompute cabling.
Q4. Can I mix ends — MPO on one side and LC / SC / FC on the other?
ʻAe. MPO-to-LC breakout is the most common configuration; MPO-to-SC and MPO-to-FC are also supported. Confirm the breakout connector type and quantity at RFQ.
Q5. Are both ends symmetric on MPO-to-MPO breakout cables?
ʻAe. For MPO-to-MPO breakouts (for example 24F into 2×12 or 3×8), the fiber count and configuration must be symmetric on both ends because every fiber core needs a one-to-one map. A hiki i 6 MPO connectors per single end are supported.
Q6. What polarity should I order for a 40G / 100G SR4 link?
Type B is the default for direct SFP+ / QSFP transceiver mating on 40G / 100G SR4. The internal crossover is done inside the cable so no external cross-connect is needed. Confirm your transceiver polarity requirement at RFQ; we ship Type A / B / C per your bill of materials.
Q7. What is the difference between standard and low-loss grade?
Standard grade holds insertion loss below 0.70 dB per mated pair; low-loss grade holds it below 0.35 dB with typical 0.25 dB. Ultra low-loss builds with Japanese ferrules reach 0.15 dB per single fiber. Low-loss and ultra low-loss are recommended for 100G high-density backbone and 400G / 800G links where every mated connector consumes link budget.
Q8. Do you 100%-test every fiber, and do you supply FLUKE / EXFO reports?
ʻAe. Every cable and every fiber core is tested for insertion loss, Hoʻi i ka pohala, end-face geometry, polarity, kaʻina fiber, length and appearance before shipment. FLUKE / EXFO electronic test reports are available on request after order confirmation.
Q9. Can I get samples before placing a bulk order?
ʻAe. Free small-quantity samples are supplied for quality verification; you only cover the shipping cost, and that shipping cost is deducted from your first formal bulk order as a cooperation incentive.
Q10. What is your monthly capacity and typical lead time?
Monthly output across the MPO family is 150,000 ʻāpana. Standard orders of several thousand pieces ship in 7–12 days from stock. Bulk orders above 20,000 pieces ship in 15–20 days. Custom packaging with full artwork runs from an MOQ of 30,000 pcs.
Q11. Can these MPO products be used outdoors?
The standard MPO line is optimised for data hall, MDA and rack environments (IP50, −20°C to +60°C, LSZH). For outdoor and FTTA applications, use the FTTA MPO/MTP Fiber Optic Patch Cord with an outdoor jacket, or ask for a custom outdoor build. Do not deploy the standard indoor jacket in unprotected outdoor conditions.
Q12. What is the warranty?
Standard warranty is 1 makahiki; design service life is up to 10 makahiki. Because 100% inspection is applied on every unit, field failures are rare; when they occur within the warranty period, we ship a replacement immediately.
E pane mākou i loko 12 hola, e ʻoluʻolu e hoʻolohe i ka leka uila me ka suffix “@fibconet.com”.
Eia kekahi, hiki iā ʻoe ke hele i ka ʻAoʻao pili, e hāʻawi ana i kahi ʻano kikoʻī.