Tafatir turjumaada
Raadi

Xidhiidhiyaha Fiber Optic&Adapter

Xidhiidhiyaha Fiber Optic & Soo saaraha Adabtarka - SC / LC / FC / MPO / ST, Simplex, Duplex & Biyo-celiska

FIBCONET waxay soo saartaa fiber optic xirayaasha iyo adapters oo daboolaya noocyada kala duwan ee qaababka loo isticmaalo gelitaanka FTTH, armaajooyinka xarunta xogta, xafiisyada dhexe ee isgaadhsiinta iyo geynta dibadda - laga bilaabo heerka SC / LC / FC / ST / MPO / MTRJ / E2000 ku IP67 / IP68 aan biyuhu ahayn Xidhiidhiyayaasha dibadda lagu qiimeeyay iyo goob-ururinta (degdeg ah) Xidhiidhiyayaasha loogu talagalay joojinta goobta.

muunad qaab dhismeedka

Xidhiidhiyaha kasta iyo adabtarada ayaa soo raacda ka dib 100% kormeerka warshad - interferometer 3D-dhamaadka wejiga MPO, gelinta luminta iyo qiyaasta khasaaraha soo noqoshada ee dhammaan noocyada fiber-ka, iyo xaqiijinta adkaysiga lammaane ee ka dhanka ah IEC 61754 iyo Telcordia GR-326-CORE (Fasalka R) habka. Gawaarida waa Sanhuan (Sumitomo codsi), Jidadka isku xira waxay ku yimaadaan darajada isgaadhsiinta caadiga ah iyada oo loo marayo PEI-ga aan biyuhu lahayn / Guryaha PDLC.

Laba Qoys oo Badeeco ah oo aanu Bixino

Qoyska 1 - Adabtarka Fiber Optic (Lamaanihii / Mating Sleeve)

Adapter (sidoo kale loo yaqaan lammaane ama gacan-qabsiga) waa qayb dadban in isku xidha laba xidhiidhiye oo fool ka fool ah gudaha guddi ODF ah, guddi balastar, saxan gidaarka ama sanduuqa joojinta. Waxay isku toosisaa labada ferrules ee ku jira dulqaadka feejignaanta adag si iftiinku u dhaafo isgoyska oo leh khasaaraha ugu yar iyo milicsiga.

Qaabka Xidhiidhiyaha Qalabka Sleeve Khasaare Gelida Caadiga ah Soo Celinta Khasaaraha
SC dhoobada (zirkoniya) ≤ 0.2 dB UPC ≥ 50 dB; APC ≥ 55 dB
LC dhoobada (zirkoniya) ≤ 0.2 dB UPC ≥ 50 dB; APC ≥ 55 dB
FC dhoobada (zirkoniya) ≤ 0.2 dB UPC ≥ 50 dB; APC ≥ 55 dB
ST dhoobada (zirkoniya) ≤ 0.2 dB UPC ≥ 50 dB
MPO / MTP polymer sax ah oo qaabaysan oo leh biin toosan ≤ 0.35 celceliska dB (khasaare yar) ≥ 55 dB (APC)
E2000, MTRJ, MU dhoobada ≤ 0.2 dB UPC ≥ 50 dB; APC ≥ 55 dB

Laga heli karo gudaha fudud, laba-labo iyo afar habaynta, oo leh flanges kor u kaca ee khaanadaha ODF ee caadiga ah, saxan darbiga, patch panel iyo goynta guddi gaar ah. Codaynta midabku waxay raacdaa heshiiska warshadaha - buluug UPC, cagaarka APC, aqua ee OM3/OM4, lime cagaaran ee OM5, beige ee OM1/OM2 - marka farsamayaqaan kastaa wuu aqoonsan karaa qaabka marka la eego.

isku xirayaasha c lc fc

Qoyska 2 - Xidhiidhiyaha Fiber Optic

Khadkayaga xidhiidhiyahayagu wuxuu u kala baxaa saddex qoys iyadoo ku xidhan hadba sida uu fiberku u go'o:

Nooca Habka Joojinta Ugu Wanaagsan
Xidhiidhiyaha Warshada-Joogtay
(oo lagu sifeeyey xariiqda xadhigga balastar-ka)
Fusion-ka-bax, epoxy + polishing in warshadda Xadhkaha dhejiska, doofaarrada, ODF horay loo joojiyay fiilooyinka - waxqabadka indhaha ee ugu sarreeya uguna joogtada ah
Goobta-Golaha (Degdeg ah) Xiriiriyaha Mechanical goob goob, looma baahna kabid fiyuus ah Gegida FTTH, joojinta xadhig-ka-dhigista, dayactirka degdega ah - eeg qaybtayada Xidhiidhiyaha degdega ah ee u heellan khadka buuxa
Biyo-celiska / Xidhiidhiyaha Dibadda
(PDLC, Pei, IP67 / IP68)
Isku-xidhka fiilada ee horay loo joojiyay oo leh guryo xiran Saldhigga saldhigga ee RRU, qalabka dibadda, waafaqsanaanta isgaarsiinta (HW / Zte / Ericsson), isku xidhka adag ee deegaanka

Loogu talagalay shirarka fiilooyinka ee horay loo joojiyay, Xidhiidhiyayaasha waxay ku dhex milmeen fiilooyinka balastar ee FIBCONET gudaha guriga - waxay ku siinayaan asalka ferrule ee la raadin karo, galinta galinta warbixinta tijaabada khasaaraha xuduntiiba, iyo waxqabadka dufcadda joogtada ah. Xidhiidhiyayaasha goobta-ururka, naga go'an Qaybta Xiriiriyaha degdega ah daboolaya dunta is-qufulka, alligator-afka, nooca khaanadaha, CCTC hal dhoobo ah, saddex-ring oo laba-ceramik ah iyo qaabab kale oo beer-raki ah oo lagu isticmaalo mashaariicda FTTH-mayl-dambe.

Sida loo Doorto Xidhiidhka Wajiga Dhammaadka Saxda ah - PC / UPC / APC

Saddexduba waxay sifeeyaan sida wejiga dhammaadka u dhalaalayo, mid walbana wuxuu bixiyaa qiimo dhimis kala duwan.

Nooca Polish Soo Celinta Khasaaraha Halkee laga Isticmaalayaa
PC (Xiriirka Jirka) ≥ 40 dB Isgaadhsiinta Legacy, Isticmaalka guud ee qiimaha jaban - oo ay inta badan ka badashay UPC
UPC (Xiriirka Jirka ee Ultra) ≥ 50 dB Xarumaha xogta, Shabakadaha Ganacsiga, inta badan fiilooyinka gudaha ee FTTH - default caadiga ah
APC (Xiriirka Jirka ee Xaglaha ah, 8° dhalaalid) ≥ 55 dB MON / FTTH dibadda warshad, CATV RF-galaas ka badan, DWDM - meel kasta oo khasaare soo noqnoqda sare leh ayaa muhiim ah si looga hortago muujinta calaamadaha

Xeerka suulka: isticmaal APC (xiriiriyaha cagaaran) wax kasta oo sita calaamad RF-modulated ama dhibic PON ah; UPC (xiriiriyaha buluugga ah) ee gaadiidka xogta caadiga ah. Waligaa ha ku biirin UPC iyo APC - xagasha poliish-ka ee is barbar dhiggu waxay keeni doontaa khasaare weyn waxayna dhaawici kartaa feeraha.

Faahfaahinta Farsamada

Halbeegga Qiimaha
U hoggaansanaanta / heerarka imtixaanka IEC 61754, Telcordia GR-326-CORE Fasalka R, IEC 61300 Fasalka U
Luminta galitaanka (caadiga ah) ≤ 0.2 dB xiriiriyaha caadiga ah; ≤ 0.35 dB MPO khasaare hoose; hoos ilaa 0.15 dB oo leh ferrules dibadda laga keeno
Soo celi khasaaraha PC ≥ 40 dB, UPC ≥ 50 dB, APC ≥ 55 dB
Adkeysiga lammaane SC / LC / FC ≥ 1,000 wareegyada; MPO ≥ 500 wareegyada
Heerkulka shaqada -40 ilaa +85 °C dibadda / biyuhu aan lahayn; -20 ilaa +60 °C heerka gudaha
Qiimaynta biyuhu celinayso (xirayaasha dibadda) IP67 / IP68
Qalabka Ferrule dhoobada Zirconia (Sanhuan caadiga ah; Sumitomo codsi); polymer sax ah oo qaabaysan oo leh biin toosan (MPO)
Qalabka guryaha Caadiga caadiga ah (gudaha); PEI ama PDLC caag injineernimada (bannaanka / biyuhu aan lahayn)

Wax-soo-saarka iyo Xakamaynta Tayada

  • 100% kormeerka wejiga dhamaadka Xidhiidhiye kasta - interferometer ee MPO, mikroskoob ee SC / LC / FC / ST
  • 100% khasaare gelinta iyo khasaaraha soo noqoshada cabbirka xudunta fiber kasta ka hor inta aan la rarin
  • Dufcaddii-ilaa-dufcaddii IL kala duwanaanshiyaha lagu xakameeyo gudaha ± 0.08 dB
  • Warbixinta imtixaanada elegtarooniga ah FLUKE ama qaabka EXFO la heli karo dalab kasta
  • Ferrules laga keenay gudaha u qalma (Sanhuan) oo laga keeno (Sumitomo) alaab-qeybiyeyaasha - ku qeex heerka dalabka shuruudaha u-fiirsashada ugu adag
  • Gacan-qabsiga qalabka wax lagu dhejiyo oo laga sameeyay dhoobada (zirkoniya) ee qaababka caadiga ah iyo polymer-ka saxda ah ee qaabaysan ee leh biinanka toosan ee MPO

kormeer tayo leh

OEM, Baakadaha & Ikhtiyaarada gaarka ah

  • Xidhiidhiyaha midabka jirka: koodka midabka isgaadhsiinta caadiga ah (UPC buluug, cagaaran APC, aqua OM3/OM4, iwm.); midabada caadadii codsi
  • Baakadaha: bacda PE shaqsi; tirooyinka kartoonnada waxaa lagu xaqiijiyay nooca xiriiriyaha iyo tirada
  • Summada gaarka ah: calaamada kartoonka dibadda ee caadada ah, dhejisyada summada iibsadaha, gelinno xaashi gaar ah
  • Isku-habaynta isku xidhaha biyuhu-ilaaliya: la jaan qaada Huawei, Zte, Ericsson iyo is-dhexgalka qalabyada telecom-ku-sheeg qalabka la beegsanayo marxaladda RFQ

baakad

Su'aalaha Inta Badan La Isweydiiyo

Q1. Waa maxay MOQ kaaga ee isku xidhayaasha iyo adabiyeyaasha?

Heerka SC / LC / FC / Adabiyeyaasha ST iyo xidhidhiyeyaashu waxay ka soo raraan kaydka iyagoon haysan MOQ adag - muunada iyo dalabaadka tijaabada waa la soo dhawaynayaa. Xidhiidhiyayaasha MPO waxay caadi ahaan ka bilaabmaan at 100 unugyo. Xidhiidhiyayaasha ku habboon biyaha iyo isgaadhsiinta (Saddexdayada mid ka mid ah beddelaha isku xirka fiber indhaha ayaa la sameeyay / Zte / Ericsson) waxaa lagu soo xigtay mashruuc kasta iyadoo ku xiran nooca guryaha.

Q2. Waa maxay farqiga u dhexeeya iskuxiraha iyo adabtarada?

A xiriiriye waa furaha dhamaadka fiilada fiber-ka - waxay xajisaa ferrule waxayna joojisaa fiber-ka. An adabtarada (sidoo kale loo yaqaan lammaane ama gacan-qabsiga) waa isgoyska dadban ee isku xira laba xiriiriye oo fool ka fool ah, isku toosinta ferruleskooda wareejinta calaamada khasaaraha hoose. ODF kasta, patch panel ama saxan darbi waxay isticmaashaa adabtarada si ay uga helaan xidhiyaasha soo galaya xadhkaha balastarka ama pigtails.

Q3. Goorma ayaan isticmaali karaa APC beddelkii UPC?

Isticmaal APC (xiriiriyaha cagaaran, 8° Polish xagal leh) PON kasta / FTTH ka baxsan isku xirka dhirta, CATV RF-galaas ka badan, iyo DWDM - meel kasta oo iftiinka iftiimaya wuxuu faragelin karaa calaamadda. Isticmaal UPC (xiriiriyaha buluugga ah) loogu talagalay taraafikada xogta caadiga ah ee xarumaha xogta, shabakadaha ganacsiga iyo inta badan fiilooyinka gudaha. Never mate UPC to APC — the angle mismatch causes major loss and can damage the ferrules.

Q4. Do you supply waterproof / outdoor connectors compatible with Huawei, ZTE or Ericsson equipment?

Haa. Waxaan soo saareynaa IP67 and IP68 waterproof connectors in PDLC and PEI housings, la jaan qaada Huawei, Zte, Ericsson and other major telecom equipment vendors. Please specify the target equipment model at RFQ stage so we can confirm the correct housing and interface spec.

Q5. Do you supply test reports?

Haa. Every shipment includes 100% factory test results (wejiga dhamaadka, khasaare galinta, khasaare soo noqda). Warbixinta imtixaanada elegtarooniga ah FLUKE ama qaabka EXFO are available on request — useful for project acceptance and customer audit.

Q6. Do you supply field-assembly (degdeg ah) xirayaasha?

Haa, we manufacture a full line of field-assembly connectors — threaded self-locking, alligator-afka, nooca khaanadaha, CCTC hal dhoobo ah, three-ring double-ceramic and more. See our dedicated Qaybta Xiriiriyaha degdega ah for the full range and specifications.

Warshadda fiidka warshadaha

Hel Xigasho Degdeg ah

Waxaan kaga jawaabi doonaa gudaha 12 saacadood, fadlan u fiirso iimaylka dabadhilifka ah "@fibconet.com".

Sidoo kale, waxaad tagi kartaa Bogga Xiriirka, kaas oo bixiya foom faahfaahsan.