Fibconet تیار کرتا ہے۔ 12 series of outdoor fiber optic splice closures (also called joint closures, cable closures, or in field slang dome cans) for OSP splicing between feeder, distribution and drop cables. Capacity ranges from 12 cores for FTTH drop junctions up to 840 cores for backbone and long-haul splice points. Sealed to IP68, housings are PP+GF, PPR or metal-braced polymer with a 15 to 25-year design field life. Our passive optical component roots trace back to 1994, and the same in-house tooling and test discipline built for PLC splitters now runs the splice closure line.

Two body types cover the two OSP install methods: dome (vertical) closures for pole, wall and direct-buried joints, اور افقی (inline) closures for manhole, handhole and figure-8 aerial splice points. منتخب گنبد ماڈل 1×8 یا 1×16 PLC سپلٹرز کے ساتھ پہلے سے بھرے ہوئے جہاز ہیں اور کوئیک ODN کے اندر PON حب پوائنٹس کے طور پر کام کرتے ہیں۔ / پہلے سے ختم شدہ FTTH تعیناتی۔. انکلوژرز مکینیکل قبول کرتے ہیں۔, ہیٹ سکڑ یا سلیکون سیلنگ فی ماڈل.
ذیل کے حصے درج ذیل ہیں۔ 12 جسمانی قسم کے لحاظ سے گروپ کردہ ماڈل, پھر ڈوم بمقابلہ افقی انتخاب کی منطق کا احاطہ کریں۔, تکنیکی وضاحتیں, مینوفیکچرنگ کی صلاحیت, پیکیجنگ, عمومی سوالات, اور ایک کوٹیشن چینل.
بیلناکار جسم جس میں ایک ہی بیس پلیٹ تمام کیبل پورٹس کو لے جاتی ہے۔. پول ماؤنٹ کے لیے بہترین موزوں ہے۔, وال ماؤنٹ اور براہ راست دفن شدہ جوڑ جہاں کیبلز ایک سرے سے داخل ہوتی ہیں۔. اسپلٹر سے بھرے ہوئے دو ماڈلز دوگنا نیچے ہیں۔ PON حب پوائنٹس فوری ODN تعیناتی کے اندر.
| ماڈل | بنیادی صلاحیت | سگ ماہی / درجہ بندی | PON مرکز کا کردار | عام استعمال |
|---|---|---|---|---|
| IK10 IP68 96 کور Huawei-مطابق رسائی ٹرمینل کی بندش | 96 کور | آئی پی 68 / IK10 اثر | - | Huawei معیاری رسائی نوڈ, قطب یا دیوار |
| 96/144 کور گنبد بندش (قطب / دیوار / زیر زمین) | 96-144 کور | آئی پی 68 | - | کثیر منظر نامہ OSP سپلائس, کسی بھی پہاڑ |
| 96/144 لازمی 100 kPa 25-Year Splice Closure | 96-144 کور | آئی پی 68 / 100 kPa air-pressure hold | - | Long-life backbone joints requiring pressure test |
| 144 Core Metal-Bracket IP68 Dome Closure | 144 کور | آئی پی 68 | - | Metal-braced tray for high-vibration or heavy cable load |
| آئی پی 68 288 Core High-capacity Dome Closure | 288 کور | آئی پی 68 | - | High-density backbone splice point |
| 1:8 / 1:16 PLC Splitter IP68 Dome (22000 ن / 10 cm cable retention) | Splitter-loaded dome | آئی پی 68 / 22000 N cable pull | Yes — Quick ODN hub | PON hub combining splice and 1×8 or 1×16 splitting |
| آئی پی 68 1:8 PLC Splitter Pre-terminated FAT Closure | splitter + FAT ports | آئی پی 68 | Yes — pre-terminated PON hub | Plug-and-play PON hub with drop-cable ports |
Elongated body with cable ports at both ends. Preferred for manhole, handhole, aerial figure-8 span and any splice point where cables enter and exit in the same axis.
| ماڈل | بنیادی صلاحیت | سگ ماہی / درجہ بندی | عام استعمال |
|---|---|---|---|
| پی پی+جی ایف / PPR IN-LINE 2-in-2-out 12 بنیادی اسپلس بندش | 12 کور | آئی پی 68 / mechanical seal | FTTH drop junction, aerial or handhole |
| 48 Core 1-in-2-out Inline Cable Closure | 48 کور | آئی پی 68 | Small branch inline splice |
| 15+ Service Years PP+GF IP68 2-in-2-out Inline Closure | تک 96 کور | آئی پی 68 / 15+ years field life | Mid-density distribution splice with long life claim |
| 96 Core Silicone-Protection Horizontal Splice Closure (اپنی مرضی کے مطابق) | 96 کور | آئی پی 68 / silicone sealing | Manhole splice with elevated moisture and chemical exposure |
| 576 / 840 Core Heat-Shrink Seal IP68 Cable Closure | 576–840 cores | آئی پی 68 / گرمی سکڑنا | Long-haul backbone splice, high-count ribbon or loose-tube |
A splice closure protects, seals and organises spliced fibers at any point along an OSP cable route. The body shape follows the physical install location, not the fiber count.
| Dome (عمودی) | Horizontal (Inline) | |
|---|---|---|
| کیبل اندراج | All ports on one base plate | Ports at two opposite ends |
| Best install | قطب, دیوار, براہ راست غمزدہ, hand-hole from top | مینہول, aerial figure-8 span, tray-mount inline |
| Typical core count | 96, 144, 288 — expandable via added trays | 12, 48, 96, 576, 840 — scales with body length |
| Access | Lift the dome, all splice trays exposed | Split the shell, access trays along the axis |
| PLC splitter loading | Common (PON مرکز کا کردار) | Less common, used mainly for pure splice |

| Core capacity | Network role | Body type shortlist |
|---|---|---|
| 12–48 cores | FTTH ڈراپ / distribution junction | Inline, mechanical seal |
| 96 کور | Access-layer PON node, base-station splice | Dome (Huawei-compatible or metal-bracket) |
| 144 کور | Distribution-layer aggregation | Dome, tray-expandable |
| 288 کور | Metro backbone splice point | Dome, اعلی صلاحیت |
| 576–840 cores | لمبی دوری کی ریڑھ کی ہڈی, high-count ribbon | Inline, heat-shrink seal |
نوٹ: the values below are family-typical ranges across the 12 series, ایک واحد SKU ڈیٹا شیٹ نہیں ہے۔. Ask us for the model-specific test report at RFQ stage; ہم اسے ماڈل پارٹ نمبر کے تحت بھیجتے ہیں۔.
| پیرامیٹر | عام قدر | تبصرہ |
|---|---|---|
| Core capacity | 12 کو 840 کور | فی ماڈل; expandable via added splice trays |
| ہاؤسنگ میٹریل | پی پی+جی ایف, پی پی آر, ABS+PC or metal-braced polymer | Selected per model and environment |
| سگ ماہی کا درجہ | آئی پی 68 | All outdoor OSP models |
| Impact resistance | Up to IK10 on selected models | Metal-bracket and IK10-rated series |
| سگ ماہی کا طریقہ | Mechanical / گرمی سکڑنا / silicone | فی ماڈل |
| Air-pressure hold | 100 kPa on selected models | For pressurised OSP networks |
| کیبل برقرار رکھنا (axial pull) | تک 22,000 ن / 10 cm on selected models | Splitter-loaded dome rated for heavy pull |
| Cable entry ports | 1-in-2-out, 2-in-2-out, 4-in-4-out per model | Additional ports available on custom builds |
| Main cable diameter | Typically Φ7–Φ16 mm | Model-dependent; branch cable Φ5–Φ11.5 mm |
| splice ٹرے | Stackable, 12 یا 24 splices per tray | Both fusion and mechanical splice trays supported |
| آپریٹنگ درجہ حرارت | −40°C to +65°C | Storage −35°C to +55°C per shipping spec |
| Design field life | 15 کو 25 years outdoor | فی ماڈل; PP+GF with UV additive supports 25 سال |
| Reference test standards | آئی ای سی 61753-1, YD/T 814, GR-771 | Applied per project requirement |
Fibconet’s optical communication background traces back to the early 1990s. Our passive optical component manufacturing roots start in 1994 with a PLC splitter factory; the company was formally structured in 2000 and today operates with 300+ core staff and an extended multi-site manufacturing network of up to 800 عملہ اور انجینئرز across China. The same tooling and test discipline built for high-count PLC splitter production now runs the splice closure line, including injection molding of PP+GF and PPR housings, splice tray forming, and full-load assembly.
Splice closures are only as reliable as the materials inside them. ہم صرف اسمبلی قدم کے بجائے اپ اسٹریم اسٹیک کو کنٹرول کرتے ہیں۔:

Fibconet operates under an integrated آئی ایس او 9001 / آئی ایس او 14001 / آئی ایس او 45001 management system covering quality, environment and occupational health & حفاظت. Raw material RoHS reports are supplied by default with every shipment.
Product-level compliance is issued per model and per target market. Depending on the model list and destination country, we can support یہ, RoHS, REACH, دی, Etl, سی پی آر, ANATEL, CCA, tlc and other market-entry documents. Applicable test reports against آئی ای سی 61753-1, YD/T 814 اور Telcordia GR-771 reference standards are provided at project scale.
Certification applicability varies by product and project requirements. Send us your target market and the model list, اور ہم قابل اطلاق سرٹیفکیٹ کوٹیشن کے ساتھ واپس کرتے ہیں۔.
All four are the same product family — an outdoor enclosure that houses and seals spliced fibers along an OSP cable route. “Splice closure” اور “joint closure” are the standard English terms. “Dome can” اور “炮筒” are field slang for the dome (vertical) body style. The Chinese term “熔接包” refers to the same category and is common in Chinese-language RFQs from Southeast Asia and Africa.
A splice closure protects and organises spliced fibers along an OSP cable route; there is no active drop-cable termination for subscribers. A distribution box (FAT) terminates drop cables into adapter ports and often houses the last-mile splitter. Splice closures sit deeper in the network; distribution boxes sit at the drop point closest to homes.
Choose dome when cables enter from a single direction — pole-mount, وال ماؤنٹ, براہ راست غمزدہ, or hand-hole accessed from above. Choose inline when cables enter and exit along the same axis — manhole splice, aerial figure-8 span, or tray-mount along a linear run.
Match the closure to the largest cable at the splice point plus a spare tray for future expansion. FTTH ڈراپ جنکشن عام طور پر 12–48 کور ان لائن بندش کا استعمال کرتے ہیں۔. PON رسائی نوڈس 96–144 کور گنبد بندش کا استعمال کرتے ہیں۔. میٹرو ریڑھ کی ہڈی کے splices استعمال کرتے ہیں 288 کور; لمبی دوری کے تنے کے ٹکڑے استعمال کرتے ہیں۔ 576 یا 840 ہیٹ سکڑ ان لائن باڈیز میں کور.
براہ راست دفن اور دباؤ والے نیٹ ورکس کے لیے, کے ساتھ ایک مکینیکل مہر گنبد کا استعمال کریں۔ 100 kPa air-pressure hold; سیل فیلڈ میں قابل تصدیق ہے اور مستقبل کے الگ الگ کام کے لئے دوبارہ داخل ہونے کے قابل ہے۔. حرارت سکڑنا زیادہ مستقل ہے لیکن بغیر کاٹے دوبارہ داخل نہیں ہو سکتا.
ہاں. گنبد بند ہونے کو فیکٹری میں پہلے سے ختم شدہ 1×8 یا 1×16 PLC سپلٹر کے ساتھ بھیجا جا سکتا ہے۔. دی 1:8 / 1:16 PLC Splitter Dome ماڈل کے لیے درجہ بندی کی گئی ہے۔ 22,000 ن / 10 سینٹی میٹر کیبل برقرار رکھنا تاکہ ہاؤسنگ بھاری ڈراپ کیبل پل کو برداشت کرے۔. سپلٹر چپس شیجیا یا کورین ماخذ ہیں۔, and pigtails use G.657.A2 fiber from major Chinese fiber brands.
PP+GF and PC+ABS housings with a UV stabiliser additive package hold 15 کو 25 years of outdoor service, depending on model. Ask us for the specific model’s material spec if your project tender requires a stated design life.
ہاں. آئی ای سی 61753-1, YD/T 814 and GR-771 test reports are available per model. Raw material RoHS reports ship by default. Market-entry certificates such as CE, REACH, دی, Etl, سی پی آر, ANATEL, CCA and TLC are issued per model and per target market. If a certificate you need is not already on file, we can arrange third-party testing at project scale.
MOQ starts at 100 pcs on standard configuration; custom builds are typically 500–1,000 pcs. Standard orders ship in 15–25 days; custom builds in 25–40 days. [ٹی بی سی: confirm exact values per model at RFQ stage.]
ہاں. Pole-mount and wall-mount hardware is included on the dome closures. Aerial figure-8 mounting kits for inline closures are supplied on request. Manhole tray mounts and cable-management brackets are quoted with the closure.
ہاں. Our splitter-loaded dome closures — the 1:8 / 1:16 PLC Splitter Dome and the pre-terminated FAT closure — act as PON hub points inside a Quick ODN system. They pair with our pre-terminated drop cables, ایم پی او حبس, sub boxes and asymmetric splitters to reduce on-site splicing, cut installation labor, and make FTTH rollout more predictable. If your project is a new FTTH build in a labor-cost-sensitive market, ask for a matched Quick ODN configuration when you send the RFQ.
ہم اندر ہی اندر جواب دیں گے۔ 12 گھنٹے, براہ کرم لاحقہ کے ساتھ ای میل پر توجہ دیں۔ "@fibconet.com".
بھی, آپ جا سکتے ہیں رابطہ صفحہ, جو مزید تفصیلی شکل فراہم کرتا ہے۔.