FIBCONET has manufactured fiber optic cable in China for 12 iminyaka, running dedicated automated lines for stranded loose-tube, central-tube, self-supporting, air-blown micro and submarine cable series.
Combined output on our mainstream armored lines (GYTS / GYTA) reaches tens of millions of fiber-kilometers per year, with stock inventory maintained across 4–288-core standard configurations.

Every drum ships after 100% factory testing — attenuation, ukuqina, water penetration and end-of-drum OTDR trace — against I-IEC 60794 uchungechunge and other applicable standards. Our submarine cable also complies with I-GB/T 18480, ITU-T G.976 and GJB 4489 military-grade specifications.
Below are the twelve cable series currently shipping to telecom operators, engineering contractors, izinsiza zamandla kanye nezihlanganisi ze-FTTH kulo lonke elaseNingizimu-mpumalanga ye-Asia, eMpumalanga Ephakathi, I-Latin America naseYurophu. Ikhasi ngalinye lomkhiqizo linezinketho zokubala zefayibha, isixhumi esilungele ukunqanyulwa kwangaphambili, kanye nemishini egcwele / imininingwane yezemvelo.
| Uhlobo Lwekhebula | Imodeli | Ukuthunyelwa | I-Max Fiber Count | Ukugqamisa Okubalulekile |
|---|---|---|---|---|
| I-Stranded Loose Tube, Insimbi-Tape Armored | GYTS | Umbhobho, -semoyeni | 288 imicu | Ukuqina kwesikhathi eside 600 N; choboza 300 N/100 mm; 20-impilo yejakhethi yonyaka |
| I-Stranded Loose Tube, I-Aluminium-Tape Armored | GYTA | Umbhobho, -semoyeni (Ipayipi le-PE lokungcwatshwa ngqo) | 288 imicu | I-anti-rodent, ukuvimba umswakama, I-EMI-ukuvikela; Inketho ye-UV-additive inweba impilo +5 iminyaka |
| I-Central Loose Tube, I-Non-Metal | I-GYXTY / I-GYFXY (I-FRP-iqiniswe) | I-Aerial, umgudu, izifunda ezithandwa umbani | 24 imicu | Engasindi, zonke-dielectric; ibhantshi phansi 1.1 mm; 10,000 km / okukhiphayo ngenyanga |
| I-All-Dielectric Self-Supporting (I-ADSS), Ijakhethi Elilodwa | Ijakhethi Elilodwa le-ADSS | I-Aerial, amaphaseji ezintambo zikagesi, ifinyelela ku 300 m | 144 imicu | Ilungu lamandla e-Aramid; Ijakhethi ye-PE 1.8 mm ± 0.1 mm; 25-40% izindleko eziphansi kune-double-jacket |
| I-ADSS, Ijakhethi eliphindwe kabili | I-ADSS Double-Jacket | I-air inkungu kasawoti ogwini, uqweqwe lweqhwa, ukufakwa kwesikhathi eside | 288 (kuya ku 576 ngokwezifiso) | 10–15 years extended service life vs single-jacket; 720 h usawoti-spray uhlolwe; UV per GB/T 18899-2023 |
| Aerial Self-Supporting (ASU) | ASU / GYFXY-lightweight | Short-span aerial & duct dual use, kuya ku 120 m ubude | 24 imicu | 3,000 h UV without cracking; 15-year warranty with 1:1 defect replacement; lower cost than ADSS |
| Figure-8 Central-Tube | I-GYXTC8S | Aerial with integral messenger, kuya ku 100 m ubude | 96 imicu | 7×1.2 galvanized steel strand messenger, 5 kN tensile; 30-year UV per IEC 60794-1 |
| Air-Blown Micro Cable | I-GCYFY / GCYFXY | Microduct systems | 144 imicu (stranded); 24 imicu (central-tube) | Outer diameter from 1.8 mm; grooved jacket for extended blowing distance; HDPE or LSZH |
| FTTH Drop Cable, Bow-Type Self-Supporting | ГХХЧЧ | FTTH outdoor drop with steel or FRP messenger | 1–4 fibers | G.657.A2 default; steel-wire or non-metallic (I-FRP) messenger; I-LSZH / VULIWE / Ijakhethi ye-PVC |
| FTTH Drop Cable, Indoor Bow-Type | GJXH | FTTH indoor drop, isikhuphukeli | 1–4 fibers | LSZH jacket standard; G.657.A2 bend-insensitive fiber |
| Intambo yokusabalalisa yangaphakathi | GJFJV / tight-buffer | Building risers, indoor cabling, patch cord raw stock | 2–24 fibers | 5 production lines × 180 km/day; long-term tensile 200 N (2.0 mm); operating −20 to +70 °C |
| Submarine Cable ⭐ | I-GYTA33 & deep-water armored | Ogwini, island interconnect, offshore platforms, deep-water up to 8,000 m | 288 imicu | 100 Gb/s unrepeated span up to 500 km; long-term tensile 4 kN, short-term 10 kN; 25-impilo yokuklama unyaka; meets GB/T 18480, I-IEC 60794, ITU-T G.976 and GJB 4489 |
OPGW (I-Optical Ground Wire) and photoelectric composite cable are also part of our line for power-utility deployments — see the OPGW product page for structural options and short-circuit current ratings.

Three questions determine the right cable for a project: where it’s installed, how many fibers it carries, futhi what mechanical / environmental loads it faces.
| Deployment Environment | Uchungechunge Olunconyiwe | Kungani |
|---|---|---|
| Umbhobho / umsele (standard telecom trunk) | GYTS or GYTA | Izikhali, high tensile, 20-Impilo Yenkonzo Yonyaka |
| I-Aerial, lightning-prone region | GYFTY / I-GYXTY (okungezona ezensimbi) or ADSS | All-dielectric prevents lightning damage |
| Aerial along power lines (spans > 100 m) | Ijakhethi Elilodwa le-ADSS (temperate) noma I-Double-Jacket (ngasogwini / uqweqwe lweqhwa) | Ukuzisekela kuze kufike 300 m; amandla e-aramid-yarn |
| Ukungcwatshwa okuqondile | I-GYTA53 (ijakhethi kabili + izikhali zensimbi-tape) noma i-GYTA + Ipayipi le-PE | Igundane, ukuchoboza nokuvikela umswakama |
| I-Microduct (ekhona noma entsha) | Air-Blown Micro Cable (I-GCYFY / GCYFXY) | 1.8 mm ubukhulu obuncane, Ijakhethi ye-groove yebanga lokushaya |
| Short-span aerial + ukusebenzisa kabili | ASU | Kushibhe kune-ADSS, ukuphakama okuphezulu kunekhebuli evamile yokudonsa |
| Aerial with integral messenger, phakathi nendawo | Umfanekiso-8 GYXTC8S | Isithunywa sensimbi esakhelwe ngaphakathi, 5 kN tensile, 100 m ubude |
| Ukwehla kwangaphandle kwe-FTTH | I-GJYXCH i-bow-type yokuzisekela | Steel noma FRP isithunywa; G.657.A2 bend-insensitive fiber |
| FTTH indoor drop / isikhuphukeli | Uhlobo lomnsalo lwangaphakathi lwe-GJXH | Ijakhethi ye-LSZH yokwakha ikhodi yomlilo |
| Ogwini, island interconnect, phesheya kwezilwandle | Ikhebula langaphansi kwamanzi (Uchungechunge lwe-GYTA33) | Ijakhethi ye-HDPE, izintambo zensimbi ezikhandiwe noma ze-Zn-Al |
| Intambo yaphansi yensiza yamandla | OPGW | Indawo yamandla ehlanganisiwe + intambo yokubona |
Ifomula yokusebenza: isamba semishini yamachweba × 2, kanye ne-spare buffer engu-10–20%.. Kumadivayisi e-serial-multiplexed isibalo singaba ngaphansi. I-fiber ejwayelekile ibala esitokweni: 2, 4, 6, 8, 12, 24, 48, 96, 144, 288. Izibalo ezingajwayelekile kufaka phakathi u-576-core (ADSS-double-jacket) ayatholakala ngesicelo.
| GYTS | GYTA | I-ADSS | |
|---|---|---|---|
| Armor | Corrugated steel tape | Corrugated aluminum tape | None (zonke-dielectric) |
| Ilungu lamandla | Intambo yensimbi (FRP for lightning zones) | Intambo yensimbi | Intambo ye-Aramid |
| Aerial span limit | ~80 m | ~80 m | Kuya ku 300 m |
| Ukungcwatshwa okuqondile | PE conduit recommended | PE conduit mandatory | Akufaneleki |
| Kuhle kakhulu | Standard duct / -semoyeni, high-rodent risk | Same as GYTS, lower weight | Long-span aerial along power poles |
| Ipharamitha | Inani |
|---|---|
| I-Fiber grade (okuzenzakalelayo) | G.652.D (mayelana 90% of shipments); G.657.A1, G.657.A2, G.654.E and OM3 / OM4 / OM5 on request |
| Ukunciphisa @ 1310 nm | ≤ 0.35 dB/km |
| Ukunciphisa @ 1550 nm | ≤ 0.21 dB/km |
| Fiber count range | 2 - 288 cores standard; kuya ku 576 cores custom (ADSS-double-jacket) |
| Irediyasi encane yokugoba | ≥ 10× cable diameter (i-static); ≥ 20× diameter (ashukumisayo) |
| Long-term tensile strength | GYTS/GYTA 600 N; Umfanekiso-8 5 kN; Submarine 4 kN long-term / 10 kN installation |
| Ukumelana nokuchoboza | ≥ 300 N/100 mm (armored series) |
| Izinga lokushisa lokusebenza | −40 kube +70 °C (ngaphandle); −20 kube +70 °C (indoor LSZH / I-PVC) |
| Impilo yesevisi yokuklama | Outdoor armored 20 iminyaka; ADSS double-jacket 25–30 years; umkhumbi-ngwenya 25 iminyaka |
| Ukuhlola | 100% drum-by-drum attenuation test; OTDR trace archived per drum |
Our submarine cable line targets short-haul unrepeated systems — island interconnect, offshore platform tie-in, izihibe zasogwini - lapho i-single-span 100 Gb/s isixhumanisi sifika ku 500 km iqeda izindleko zabaphindayo be-subsea, amandla okuphakelayo kanye nokugcinwa.
I-GYTS yethu / Imigqa ye-GYTA isebenzisa imishini yokufaka amakhebula evela kwamanye amazwe, high-speed secondary enamathela imishini, kanye nemigqa yejakhethi enezingqimba ezimbili. Amageji e-laser concentricity gauge kanye nezikena zesikhathi sangempela ze-OTDR ziqapha zonke izinyathelo. Inqubo yezinyathelo ezintathu yokuvimbela amanzi ilawula ubude befiber eyeqile, tape i-thermal bonding kanye nemingcele ye-extrusion yejacket ngokusebenzisa ukulawulwa kwenqubo yedijithali.
Standard drum length is 1–3 km per wooden reel for most trunk series; custom drum lengths supported on request. Approximate cable-length loading per container for figure-8 and similar profiles:
Actual loading depends on cable diameter, drum size and stacking configuration — our sales team will calculate exact quantities against your PO.
Ukusetshenziswa kwesitifiketi kuyehluka ngomugqa womkhiqizo kanye nemakethe yendawo. Sicela uqinisekise izwe okuqondiswe kulo, indawo yokuthunyelwa kanye namazinga adingekayo lapho ucela ikhotheshini.
Standard trunk cable MOQ is 1 km. Indoor distribution cable also 1 km MOQ; custom-colour indoor cable requires 5 km. Submarine cable typically starts at 100 km due to the specialized production line setup. Bow-type drop cable ships from standard stock.
Regular 2–48-core GYTS / GYTA / I-GYXTY / ASU configurations ship from stock within days. Custom fiber counts, lengths or non-standard jackets: typically 15–25 working days depending on drum count. Submarine cable and 288-core+ builds require project-specific scheduling.
Mayelana 90% of our finished cable ships with G.652.D i-fiber yemodi eyodwa. G.657.A1 and G.657.A2 bend-insensitive grades are our default for drop cable and tight-space installations. G.654.E for long-haul 400G+ backbone and OM3 / OM4 / OM5 multimode for data-centre indoor cable are available on request.
Yebo. Every drum ships after 100% attenuation testing, with the OTDR trace archived. Written test reports covering tensile, water penetration and thermal aging are available under IEC 60794 methodology on request — useful for project acceptance and customs clearance.
Yebo. Standard drums are 1–3 km; longer runs supported on request (isib. ADSS in 500 m, 1200 m or segmented lengths). Jacket colour customization has a 5 km MOQ. Sequential metre marking, batch code and buyer logo can be printed to your specification.

Our cable ships with ISO 9001, LOKHU, RoHS and IEC 60794 compliance as standard. i / ETL certifications are supported for North American entry; CPR is available for cable installed in permanent European buildings. Third-party test reports and country-specific certification can be arranged per project.
Impendulo emfushane: sebenzisa GYTS or GYTA for standard duct / aerial trunk cabling; GYFTY when a non-metallic (unarmored) cable is required; Ijakhethi elilodwa le-ADSS for aerial spans up to 300 m in temperate conditions, ijakhethi kabili for coastal salt-fog or ice-loaded spans; ASU for short-span aerial + duct dual-use where you want the strength of ADSS without the cost. Detailed matrix above.
For direct burial we recommend I-GYTA53 (double-jacket with steel-tape armor) or GYTA with an additional PE protective conduit. Standard single-jacket ASU and ADSS are not designed for direct burial — the buried environment will corrode the jacket over time.
Iwaranti yasembonini ejwayelekile 1 unyaka. Impilo yesevisi yokuklama: 20 years for standard outdoor armored cable; 25–30 years for ADSS double-jacket and submarine cable; 15 years for ASU with 1:1 defect replacement if the failure is traced to manufacturing.