Hlela Ukuhumusha
Sesha

Ukuvalwa kwe-Fiber optic Splice

Umkhiqizi Wokuvalwa Kwe-Fiber Optic Splice - Dome kanye ne-Inline, 12 ku 840 Ama-cores

I-Fibconet ikhiqiza 12 uchungechunge lwangaphandle ukuvalwa kwe-fiber optic splice (ebizwa futhi ukuvalwa okuhlangene, ukuvalwa kwekhebula, noma ku-slang yasendle amathini edome) ngokuxhumanisa i-OSP phakathi kokuphakelayo, ukusatshalaliswa nokulahla izintambo. Amandla ahluka ukusuka 12 ama-cores we-FTTH drop junctions phezulu 840 ama-cores we-backbone kanye namaphoyinti ama-splice amade. Ivalwe ku-IP68, Izindlu ziyi-PP+GF, I-PPR noma i-polymer eboshwe ngensimbi ene-a 15 kuya eminyakeni engama-25 yokuphila komkhakha wokuklama. Izimpande zethu ze-passive optical component zilandela emuva 1994, kanye nesiyalo esifanayo sangaphakathi samathuluzi sokuhlola esakhelwe izihlukanisi ze-PLC manje sesisebenzisa umugqa wokuvala we-splice.

kuyini ukuvalwa kwe-splice

Izinhlobo ezimbili zomzimba zihlanganisa izindlela ezimbili zokufaka i-OSP: idome (mpo) ukuvalwa okwesigxobo, udonga kanye namalunga angcwatshwe ngqo, futhi evundlile (emugqeni) ukuvalwa ngomgodi, i-handhole kanye ne-figure-8 yezindawo zokuhlanganisa zasemoyeni. Amamodeli we-dome akhethiwe athunyelwa kusengaphambili ngezihlukanisi ze-1 × 8 noma 1 × 16 PLC futhi asebenze njengamaphoyinti ehabhu le-PON ngaphakathi kwe-ODN esheshayo / ukuthunyelwa kwe-FTTH okunqanyulwe ngaphambilini. Izivalo zamukela okomshini, i-heat-shrink noma i-silicone sealing ngemodeli ngayinye.

Izigaba ezingezansi zibala i 12 amamodeli aqoqwe ngohlobo lomzimba, bese uvala indlela yokukhetha ye-Dome-vs-Horizontal, imininingwane yezobuchwepheshe, ikhono lokukhiqiza, ukupakisha, FAQ, kanye neshaneli yokucaphuna.

12 Amamodeli Okuvalwa Kwe-Splice Siyawakha

Iqembu 1 — Dome (Iqondile) Ukuvalwa Kwezinsimbi

Umzimba oyi-cylindrical one-base plate ephethe zonke izimbobo zekhebula. Ifaneleka kakhulu i-pole-mount, ukukhwezwa odongeni kanye nokungcwatshwa okuqondile lapho izintambo zingena zisuka ekugcineni. Amamodeli amabili alayishwe isihlukanisi ngezansi aphindwe kabili njenge Amaphoyinti ehabhu le-PON ngaphakathi kokuthunyelwa kwe-ODN esheshayo.

Imodeli Amandla Abalulekile Ukubeka uphawu / Isilinganiso Indima ye-PON hub Ukusetshenziswa Okuvamile
IK10 IP68 96 Ukuvalwa Kwetheminali Yokufinyelela Okuhambisanayo ne-Core Huawei 96 ama-cores IP68 / Umthelela we-IK10 - I-Huawei-standard access node, isigxobo noma udonga
96/144 Ukuvalwa kwe-Core Dome (Isigxobo / Udonga / Ngaphansi komhlaba) 96- ama-cores angu-144 IP68 - I-Multi-scenario OSP splice, noma iyiphi intaba
96/144 Ingqikithi 100 I-kPa 25-Year Splice Closure 96- ama-cores angu-144 IP68 / 100 i-kPa air-pressure - Amalunga omgogodla wempilo ende adinga ukuhlolwa kwengcindezi
144 I-Core Metal-Bracket IP68 Dome Ukuvalwa 144 ama-cores IP68 - Ithreyi eboshwe ngensimbi yokudlidliza okuphezulu noma ikhebula elisindayo
IP68 288 I-Core High-Capacity Dome Ukuvalwa 288 ama-cores IP68 - Iphoyinti le-splice backbone ephezulu
1:8 / 1:16 I-PLC Splitter IP68 Dome (22000 N / 10 cm ukugcinwa kwekhebula) Idome elayishwe nge-splitter IP68 / 22000 Ukudonsa kwekhebula le-N Yebo - Ihabhu le-ODN esheshayo Ihabhu le-PON elihlanganisa uhlaka kanye nokuhlukaniswa okungu-1×8 noma okungu-1×16
IP68 1:8 I-PLC Splitter Enqanyulwe Ngaphambi Kokuvalwa kwe-FAT I-Splitter + Amachweba we-FAT IP68 Yebo - ihabhu ye-PON enqanyulwe ngaphambilini Xhuma futhi udlale ihabhu ye-PON enezimbobo zekhebula lokudonsa

Iqembu 2 - Evundlile (Emugqeni) Ukuvalwa Kwezinsimbi

Umzimba omude onezimbobo zekhebula emikhawulweni yomibili. Kuncanyelwa umgodi wokucasha, imbobo, i-air figure-8 span kanye nanoma iyiphi indawo yokuhlukanisa lapho izintambo zingena futhi ziphuma ku-eksisi efanayo.

Imodeli Amandla Abalulekile Ukubeka uphawu / Isilinganiso Ukusetshenziswa Okuvamile
PP+GF / I-PPR IN-LINE 2-in-2-out 12 Ukuvalwa kwe-Splice Core 12 ama-cores IP68 / uphawu lomshini I-FTTH drop junction, i-air noma i-handhole
48 Core 1-in-2-out Inline Cable Closure 48 ama-cores IP68 Small branch inline splice
15+ Service Years PP+GF IP68 2-in-2-out Inline Closure Kuya ku 96 ama-cores IP68 / 15+ years field life Mid-density distribution splice with long life claim
96 Core Silicone-Protection Horizontal Splice Closure (Ngokwezifiso) 96 ama-cores IP68 / silicone sealing Manhole splice with elevated moisture and chemical exposure
576 / 840 Core Heat-Shrink Seal IP68 Cable Closure 576–840 cores IP68 / ukushisa-shwabana Long-haul backbone splice, high-count ribbon or loose-tube

What Is a Splice Closure and How to Choose the Right Type

Dome vs Horizontal — The Two Body Types

A splice closure protects, seals and organises spliced fibers at any point along an OSP cable route. The body shape follows the physical install location, not the fiber count.

Dome (Iqondile) Horizontal (Emugqeni)
Ukufakwa kwekhebula All ports on one base plate Ports at two opposite ends
Best install Isigxobo, udonga, kungcwatshwe ngqo, hand-hole from top Umjondolo, aerial figure-8 span, ugqoko-khweza emgqeni
Ukubala okuyisisekelo okujwayelekile 96, 144, 288 - inwebeka ngamathreyi angeziwe 12, 48, 96, 576, 840 - izikali ezinobude bomzimba
Ukufinyelela Phakamisa idome, wonke ama-splice tray aveziwe Hlukanisa igobolondo, amathreyi okufinyelela ku-eksisi
Ukulayishwa kwesihlukanisi se-PLC Okuvamile (Indima ye-PON hub) Okungajwayelekile, esetshenziselwa ikakhulukazi ukuhlanganisa okuhlanzekile

izinhlobo zokuvalwa kwe-splice

Indlela yokufaka uphawu - Mechanical, I-Heat-Shrink noma i-Silicone

  • Mechanical seal (i-compress grommet + i-rubber gasket): kungeneka kabusha, asikho isibani esidingekayo, ukufakwa kwenkambu esheshayo. Okujwayelekile kumamodeli amaningi edome namancane asemgqeni.
  • I-Heat-shrink seal: amandla aphezulu okubamba, uphawu oluhlala njalo, okujwayelekile ekubaleni okuphezulu okungu-576–840 kokuvalwa komgogodla okuphakathi komugqa. Idinga ithoshi nabasebenzi abaqeqeshiwe.
  • I-Silicone / i-gel seal: isetshenziswa lapho iphoyinti lokuhlukanisa libona umswakama omile, amafutha noma amakhemikhali anolaka; ingene kabusha ngaphandle kokushisa.

Indlela Yokufanisa Ukuvalwa Nesimo Sensimu Yakho

  • I-FTTH drop junction kumfanekiso wasemoyeni-8 → 12-core inline mechanical seal.
  • Ihabhu le-PON elinesihlukanisi esingu-1×8 noma esingu-1×16 → Ukuvalwa kwedome okulayishwe isihlukanisi ngezimbobo ezinqanyulwe kusengaphambili; izikhala ku-Quick ODN deployment.
  • I-splice yomgogodla ongcwatshwe ngokuqondile edinga ukuhlolwa kwengcindezi → 96/144 core dome, 100 i-kPa air-pressure, 25-impilo yokuklama unyaka.
  • I-splice yembobo enendawo emanzi → ukuvalwa okuvundlile ngokuvalwa kwe-silicone.
  • I-long-hall noma i-metro trunk splice, inani elikhulu le-fiber → 576 noma 840 ukuvalwa kokunciphisa ukushisa okuphakathi komugqa.
  • I-pole splice enomthwalo osindayo wethreyi noma ukudlidliza → idome yensimbi yobakaki, ithreyi elivikelwe ukuzinza kwemishini.

I-Fiber Count Selection Guide

Amandla amakhulu Indima yenethiwekhi Uhlu olufushane lohlobo lomzimba
12- ama-cores angama-48 Ukwehla kwe-FTTH / ukuhlangana kokusabalalisa Emugqeni, uphawu lomshini
96 ama-cores Indawo ye-PON yesendlalelo sokufinyelela, isisekelo sesiteshi Dome (I-Huawei-ehambisanayo noma i-metal-bracket)
144 ama-cores Ukuhlanganiswa kwesendlalelo sokusabalalisa Dome, ithreyi-liyanwebeka
288 ama-cores I-Metro backbone splice point Dome, amandla aphezulu
576–840 cores Umgogodla wokudonsa isikhathi eside, iribhoni ephezulu Emugqeni, ukushisa-shrink uphawu

Ukucaciswa kobuchwepheshe

Qaphela: amanani angezansi ayizigaba ezijwayelekile zomndeni kulo lonke 12 uchungechunge, akuyona idatha ye-SKU eyodwa. Sicele ngombiko wokuhlola wemodeli ethile esigabeni se-RFQ; siyithumela ngaphansi kwenombolo yengxenye yemodeli.

Ipharamitha Inani Elijwayelekile Phawula
Amandla amakhulu 12 ku 840 ama-cores Ngokwemodeli; anwebeka ngamathreyi ahlanganisiwe
Impahla yezindlu PP+GF, I-PPR, I-ABS+PC noma i-polymer eboshwe ngensimbi Kukhethwe imodeli ngayinye nendawo
Ibanga lokuvala IP68 Wonke amamodeli we-OSP angaphandle
Ukumelana nomthelela Kufika ku-IK10 kumamodeli akhethiwe Ubakaki bensimbi kanye nochungechunge olulinganiselwe nge-IK10
Indlela yokufaka uphawu Omakhenikha / ukushisa-shwabana / i-silicone Ngokwemodeli
Ukubamba ingcindezi yomoya 100 kPa kumamodeli akhethiwe Okwamanethiwekhi e-OSP anengcindezi
Ukugcinwa kwekhebula (ukudonsa kwe-axial) Kuya ku 22,000 N / 10 cm kumamodeli akhethiwe Idome elilayishwe i-splitter likalwe ukudonsa kanzima
Izimbobo zokungena zekhebula 1-ku-2-ngaphandle, 2-ku-2-ngaphandle, 4-ku-4-out ngemodeli ngayinye Izimbobo ezengeziwe zitholakala ekwakhiweni ngokwezifiso
Idayamitha yekhebula eyinhloko Ngokuvamile Φ7–Φ16 mm Kuncike kumamodeli; ikhebula legatsha Φ5–Φ11.5 mm
I-splice tray Iyabekeka, 12 noma 24 izingcezu ngethreyi ngayinye Kokubili amathreyi e-fusion kanye nemishini yokuhlanganisa asekelwe
Izinga lokushisa lokusebenza −40°C kuya +65°C Isitoreji −35°C ukuya ku-+55°C nge-specpe ngayinye yokuthunyelwa
Impilo yasensimini yokuklama 15 ku 25 iminyaka ngaphandle Ngokwemodeli; I-PP+GF enezisekelo ze-UV 25 iminyaka
Izilinganiso zokuhlola eziyisethenjwa I-IEC 61753-1, YD/T 814, GR-771 Kusetshenziswa ngokwesidingo sephrojekthi ngayinye

Amandla Okukhiqiza Nokulawula Ikhwalithi

Umlando Wokukhiqiza Nethimba

Isizinda sokuxhumana esibonakalayo seFibconet sisukela ekuqaleni kwawo-1990. Izimpande zethu zokukhiqiza zengxenye ye-optical ziqala phakathi 1994 ngemboni yokuhlukanisa i-PLC; inkampani yakhiwe ngokusemthethweni 2000 futhi namuhla isebenza nge 300+ abasebenzi abasemqoka kanye nenethiwekhi enwetshiwe yokukhiqiza yezindawo eziningi efinyelela ku 800 abasebenzi kanye nonjiniyela kulo lonke elaseShayina. Ithuluzi elifanayo nesiyalo sokuhlola esakhelwe ukukhiqizwa okuphezulu kwe-PLC okuhlukanisayo manje sesisebenzisa umugqa wokuvala we-splice, kufaka phakathi ukubunjwa komjovo we-PP+GF kanye nezindlu ze-PPR, ukwakha ithreyi le-splice, kanye nokuhlanganiswa komthwalo ogcwele.

Ukulawulwa Kwezinto Eziphezulu

Ukuvalwa kwe-splice kunokwethenjelwa kuphela njengezinto ezingaphakathi kuzo. Silawula isitaki esikhuphuka nomfula kunesinyathelo somhlangano kuphela:

  • I-resin yezindlu: amamaki afanelekile e-PP+GF kanye ne-PPR anesiqinisi se-UV kanye nephakheji lesengezo le-weathering-modifier elifakwe ku-pre-mix.
  • Ukuvala irabha kanye ne-silicone: amabanga afanelekayo afaniswa nebanga lokushisa elisebenzayo kanye nempilo yenkambu elinganiselwe.
  • Amathreyi okuhlanganisa kanye nabakaki bensimbi: kukhiqizwe ekusetshenzisweni kwamathuluzi okuzinikele kokuvumelana kobukhulu kuwo wonke amaqoqo okukhiqiza.
  • Izingxenye ezibonakalayo ze-Passive Optical ngaphakathi kokuvalwa okulayishwe isihlukanisi: Shijia / I-Korean-source PLC chips, I-NTT-grade optical epoxy, I-CCTC Ceramic Ferrules, kanye ne-G.657.A2 pigtail fiber etholakala kumabhrendi amakhulu e-Chinese fiber (I-Fiberhome, YOFC, Hengtong).

Ikhwalithi yokulawula

into uqobo lwayo

  • Ukuhlola ukubamba ingcindezi yomoya kukho konke ukuvalwa kwedome okuhlanganisiwe ngaphambi kokuthunyelwa (100 kPa kumamodeli akaliwe).
  • Ukuhlolwa okungangeni manzi nokuvikela izintuli ebangeni le-IP68 elilinganiselwe kumasampuli okukhiqiza iqoqo ngalinye.
  • Ukuhlolwa komthelela ngokwezinga le-IK elilinganiselwe kumasampula ezindlu.
  • Ukuhlolwa kokudonsa kokugcinwa kwekhebula ngomthwalo we-axial okaliwe (kuya ku 22,000 N / 10 cm kudome elayishwe isihlukanisi).
  • Umjikelezo wokushisa nokuhlolwa komswakama ngokweziqu zemodeli.
  • Ukuhlolwa kwethreyi yokulayisha okugcwele ngamathreyi okuhlanganisa kanye nezihlukanisi ezifakiwe, ukuze uqinisekise ukulingana kokuphathwa kwekhebula ngaphansi komthwalo wembobo wangempela.

Izitifiketi Nokuthobelana

I-Fibconet isebenza ngaphansi kokuhlanganisiwe ISO 9001 / ISO 14001 / ISO 45001 uhlelo lokuphatha oluhlanganisa ikhwalithi, imvelo kanye nempilo yomsebenzi & ukuphepha. Imibiko ye-RoHS yempahla eluhlaza inikezwa ngokuzenzakalela kukho konke okuthunyelwayo.

Ukuthobela izinga lomkhiqizo kukhishwa ngemodeli ngayinye kanye nemakethe eqondiwe. Kuye ngohlu lwamamodeli kanye nezwe lapho uya khona, singasekela LOKHU, I-RoHS, FIKA, i, Ukutolika, CPR, I-ANATEL, I-CCA, I-TLC kanye neminye imibhalo yokungena emakethe. Imibiko yokuhlola esebenzayo ngokumelene I-IEC 61753-1, YD/T 814 futhi I-Telcordia GR-771 amazinga okubhekisela anikezwa esikalini sephrojekthi.

Ukusetshenziswa kwesitifiketi kuyehluka ngomkhiqizo nezidingo zephrojekthi. Sithumelele imakethe yakho oyihlosile kanye nohlu lwamamodeli, futhi sibuyisela isitifiketi esisebenzayo esisethwe kanye nekhotheshini.

Ukuwowapha, OEM kanye Custom Izinketho

Ukupakisha Okujwayelekile Kokuthekelisa

  • Izikhwama zesekeli (amathreyi e-splice, ama-grommets, amathuluzi) ngaphakathi kwezikhwama zepulasitiki ezivikela umswakama.
  • Ibhokisi langaphakathi elivikela umswakama kanye nebhokisi langaphakathi elivikela ukushaqeka ngakunye ukuvalwa ngakunye.
  • Ibhokisi lokuthekelisa eliyingcweti elimakwe amalebula avikela umswakama kanye nokuma kwawo.
  • Izinga lokushisa lokuthutha: −35°C kuya +55°C.
  • Ibanga lokushisa lesitoreji: −5°C ukuya +45°C, umswakama ohlobene ngezansi 75%.

OEM kanye Custom Izinketho

  • Ilogo ye-OEM nelebula: I-laser ephawulwe endlini, printed on inner and master carton.
  • Custom port layout: extra cable entries or blanks per your project drawing.
  • Splitter pre-loading: 1×8, 1×16 or custom ratio installed at factory for Quick ODN and PON hub roles.
  • Splice tray count: pre-loaded with the exact tray count and adapter set your project requires.
  • Mounting kit: insika, udonga, aerial-figure-8 or manhole kit bundled per order.
  • CAD drawings and installation manuals supplied on request for project design review.
  • I-MOQ: 100 pcs per model on standard configuration; 500–1,000 pcs on custom builds. [TBC: confirm per model]
  • Lead time: 15–25 days for standard orders; 25–40 days for custom builds. [TBC: confirm]

imibuzo ejwayelekile ukubuzwa

Q1. What do buyers mean by “ukuvalwa kwe-splice”, “joint closure”, “dome can” noma “熔接包”?

Bobane bawumndeni womkhiqizo ofanayo - indawo ebiyelwe yangaphandle enezindlu futhi ivale imicu ehlukene eduze komzila wekhebula le-OSP.. “Ukuvalwa kwe-splice” futhi “joint closure” amagama ajwayelekile esiNgisi. “Dome can” futhi “umgqomo” ziyi-field slang ye-dome (mpo) isitayela somzimba. Igama lesiShayina “熔接包” ibhekisela esigabeni esifanayo futhi ivamile kuma-RFQ olimi lwesiShayina avela eNingizimu-mpumalanga ye-Asia nase-Afrika.

Q2. Uyini umehluko phakathi kokuvalwa kwe-splice nebhokisi lokusabalalisa?

Ukuvalwa kwe-splice kuvikela futhi kuhlele imicu ehlukene eduze komzila wekhebula le-OSP; akukho ukunqanyulwa kwekhebula lokudonsa okusebenzayo kwababhalisile. Ibhokisi lokusabalalisa (FAT) inqamula izintambo ezikhumulweni ze-adaptha futhi ngokuvamile igcina isihlukanisi semayela lokugcina. Ukuvalwa kwama-splice kuhlala kujule kunethiwekhi; amabhokisi okusabalalisa ahlala endaweni yokulahla eduze nemizi.

Q3. Kufanele ngikhethe nini ukuvalwa kwedome nalapho ukuvalwa kwe-inline?

Khetha idome lapho izintambo zingena zisuka ohlangothini olulodwa — i-pole-mount, ukukhweza odongeni, kungcwatshwe ngqo, noma imbobo yesandla efinyelelwe phezulu. Khetha emgqeni lapho izintambo zingena futhi ziphuma nge-eksisi efanayo — umgodi womgodi, aerial figure-8 span, noma faka ithreyi ngokugijima komugqa.

Q4. Yimuphi umthamo obalulekile engiwudingayo?

Fanisa ukuvalwa kwekhebuli enkulu kunazo zonke endaweni ye-splice kanye nethreyi eliyisipele lokunwetshwa okuzayo. Izixhumanisi zokudonsa ze-FTTH ngokuvamile zisebenzisa ukuvalwa kwe-inline okuyinhloko okungu-12–48. Amanodi okufinyelela e-PON asebenzisa ukuvalwa kwe-96–144 core dome. Ukusetshenziswa kwe-metro backbone splies 288 ama-cores; ukusetshenziswa kwe-trunk splices isikhathi eside 576 noma 840 ama-cores emizimbeni esemgqeni enciphisa ukushisa.

Q5. Iyiphi indlela yokubeka uphawu enokwethenjelwa kakhulu ngokuhlanganyela okungcwatshwe ngokuqondile?

Okwamanethiwekhi angcwatshwe ngqo nacindezelwe, sebenzisa idome lomshini-seal nge 100 i-kPa air-pressure; uphawu luyaqinisekiswa ensimini futhi lungeneka kabusha emsebenzini wokuhlanganisa wesikhathi esizayo. I-Heat-shrink ingunaphakade kodwa ayiphinde ingene ngaphandle kokusikwa.

Q6. Ingabe unikezela ngokuvalwa okulayishwe ngaphambili ngesihlukanisi se-PLC?

Yebo. Ukuvalwa kwe-Dome kungathunyelwa nge-1 × 8 noma 1 × 16 PLC isihlukanisi esinqanyulwe kuqala efektri.. I 1:8 / 1:16 Imodeli ye-PLC Splitter Dome ikalelwe 22,000 N / 10 cm ukugcinwa kwekhebula ukuze indlu ibekezelele ukudonsa kwekhebula elidonsa kanzima. Ama-splitter chips yi-Shijia noma umthombo waseKorea, kanye ne-pigtails zisebenzisa i-G.657.A2 ifayibha evela kumikhiqizo emikhulu ye-Chinese fiber.

Q7. Ithini impilo yasensimini yangaphandle?

Izindlu ze-PP+GF ne-PC+ABS ezinephakeji lesengezo se-UV esiqinile 15 ku 25 iminyaka yenkonzo yangaphandle, kuye ngemodeli. Sicele imininingwane yemodeli ethile uma ithenda yephrojekthi yakho idinga impilo eshiwo yokuklama.

Q8. Ingabe uyayihlinzeka ngemibiko yokuhlolwa kanye nemibhalo yokuvumelana evamile yamazwe ngamazwe?

Yebo. I-IEC 61753-1, YD/T 814 kanye nemibiko yokuhlola ye-GR-771 iyatholakala ngemodeli ngayinye. I-RoHS ibika ukuthunyelwa ngokuzenzakalelayo. Izitifiketi zokungena emakethe ezifana ne-CE, FIKA, i, Ukutolika, CPR, I-ANATEL, I-CCA ne-TLC zikhishwa ngemodeli ngayinye kanye nemakethe eqondiwe. Uma isitifiketi osidingayo singekho efayilini, singahlela ukuhlolwa komuntu wesithathu esikalini sephrojekthi.

Q9. Ithini i-MOQ yakho nesikhathi sokuhola esijwayelekile?

I-MOQ iqala ngo 100 ama-pcs ekucushweni okujwayelekile; ukwakhiwa ngokwezifiso kuvamise ukuba ngama-pcs angama-500–1,000. Ama-oda ajwayelekile athunyelwa ezinsukwini eziyi-15–25; ngokwezifiso zakha ezinsukwini ezingama-25-40. [TBC: qinisekisa amanani aqondile ngemodeli ngayinye esigabeni se-RFQ.]

Q10. Ingabe uyanikezela ngezingxenyekazi zekhompuyutha zokukhweza ukuze kufakwe isigxobo nomgodi?

Yebo. Izingxenyekazi zekhompuyutha ze-pole-mount ne-wall-mount zifakiwe ekuvaleni kwe-dome. Amakhithi okukhweza we-Aerial figure-8 okuvalwa okusemgqeni ahlinzekwa ngesicelo. Ukukhwezwa kwethreyi ye-manhole nabakaki bokuphatha ikhebula kucashunwe lapho kuvalwa.

Q11. Ingabe lokhu kuvalwa kwe-splice kungasetshenziswa ku-Quick ODN noma ukuthunyelwa kwe-FTTH okunqanyulwe ngaphambilini?

Yebo. Ukuvalwa kwedome yethu elayishwe yizihlukanisi - the 1:8 / 1:16 I-PLC Splitter Dome kanye nokuvalwa kwe-FAT okunqanyulwe ngaphambili - kusebenza njengamaphoyinti ehabhu le-PON ngaphakathi kwesistimu ye-Quick ODN. Abhanqa nezintambo zethu zokuwisa ezinqanyulwe ngaphambilini, Izindawo ze-MPO, amabhokisi amancane kanye nezihlukanisi ze-asymmetric ukunciphisa ukuhlanganisa endaweni, ukusika umsebenzi wokufaka, futhi wenze ukukhishwa kwe-FTTH kubikezeleke kakhudlwana. Uma iphrojekthi yakho iyinhlangano entsha ye-FTTH emakethe ezwela izindleko zabasebenzi, cela ukucushwa kwe-Quick ODN okufanayo lapho uthumela i-RFQ.

Thola Isilinganiso Esisheshayo

Sizophendula ngaphakathi 12 amahora, sicela unake i-imeyili enezijobelelo "@fibconet.com".

Futhi, ungaya ku Ikhasi Lokuxhumana, elihlinzeka ngefomu elinemininingwane eyengeziwe.