Submarine Fiber Optic Cable Types and Layers: A Route-Based Selection Guide

A submarine fiber optic cable carries data through optical fibers. A submarine power cable carries electrical power through metallic conductors and a high-voltage insulation system. Both may use steel-wire armour and polymer coverings, so the outer appearance alone does not identify the cable category.
Factory-safe schematic seabed profile drawn in code; no product photo used
Table of Contents

Submarine telecom cables also differ within their own category. A lightweight cable for a deep-ocean route does not use the same protection system as a cable installed near anchors, fishing gear, rocks, or a shore landing. The route depth matters, but seabed conditions, burial plans, installation loads, repair methods, and external hazards also affect the cable design.

This guide separates system type from protection type, explains the main cable layers, and shows where a deep-sea BYUOC-1 LW cable and a near-shore GYTA33/GYFTY33 cable fit.

Submarine Fiber Optic Cable vs. Submarine Power Cable

“Submarine cable” can refer to telecom, power, or composite products. The first RFQ step is to identify what the cable must carry.

Selection questionSubmarine fiber optic cableSubmarine power cableRFQ wording
What does it transmit?Optical data signalsElectrical powerState data rate/system role or voltage and power rating
What is the functional core?Optical fibers inside a protected optical unitCopper or aluminium conductors with an insulation systemSpecify fiber type/count or conductor cross-section and voltage
Can it include metallic parts?Yes. Some designs use steel wires, a copper tube, or another conductive pathYes. Conductors, screens, metallic sheaths, and armour are commonDo not classify the cable by armour alone
Does steel-wire armour prove it is a power cable?NoNoAsk for a cross-section and product standard
Can one cable carry both power and data?A composite cable can include optical units and power conductorsA power cable may contain integrated optical unitsIdentify it as a submarine composite cable

A drawing that shows steel wires and a polyethylene covering does not settle the question. Look for the optical unit, conductor system, insulation layers, voltage rating, fiber count, and applicable product specification.

Two Classifications Answer Different Questions

Submarine fiber optic cables can be classified by system application and by protection level. Mixing these classifications creates misleading product comparisons.

System application

ITU-T G.978 identifies three application groups:

  • Repeatered submarine cable: used in a system with electrically powered underwater optical repeaters.
  • Repeaterless submarine cable: used without in-line repeaters. Passive amplification may still form part of a system design.
  • Dedicated sensing submarine cable: designed for a sensing application defined by the relevant system specification.

These labels describe the system. They do not tell an engineer whether the cable has lightweight, single-armoured, or double-armoured protection.

ITU-T G.978 classification and the published article text

Protection level

The same ITU-T Recommendation lists five protection classes:

  • Lightweight (LW)
  • Lightweight Protected (LWP)
  • Single Armoured (SA)
  • Double Armoured (DA)
  • Rock Armoured (RA)

A manufacturer may also offer variants such as Single Armoured Lightweight (SAL). Such a designation is a product-family variant, not an additional class in the five-part ITU-T list.

What Are the Layers of a Submarine Fiber Optic Cable?

There is no universal layer stack for every submarine fiber cable. A repeatered oceanic cable, a repeaterless lightweight cable, and a steel-wire-armoured coastal cable can use different optical units, strength systems, metallic barriers, coverings, and conductors.

User-supplied GYTA33-style cross-section; user-supplied BYUOC-1 LW cross-section; programmatic English redraw of leaders and labels

The following functions appear across many designs.

Layer or componentFunctionWhat may changeEvidence to request
Optical fibersCarry data as optical signalsFiber standard, attenuation, dispersion, effective area, core countModel-level fiber list and optical specification
Fiber gel or water-blocking materialLimits water movement around the fibersGel, yarn, tape, dry water-blocking systemWater-penetration method and result
Stainless-steel tube or loose tubeProtects and organizes fibersTight or loose construction, tube material, fiber excess lengthCross-section, tube dimensions, qualification report
Strength systemCarries installation, recovery, repair, and permanent loadsCentral strength member, inner steel wires, external armourCBL, NTTS, NOTS, NPTS, bend limits
Metallic barrier or tubeCan provide a moisture barrier, mechanical protection, or conductive pathCopper, aluminium, stainless steel, coated tapeMaterial specification and electrical parameters
Insulation or inner sheathElectrically and mechanically separates inner componentsPE formulation, thickness, bonding methodThickness tolerance and electrical test data
ArmourAdds protection against handling and external aggressionWire count, diameter, material, coating, one or two layersArmour drawing, tensile and impact results
Outer coveringProtects against seawater exposure and abrasionPE, PP yarn, bitumen, other route-specific coveringMaterial grade, abrasion and environmental tests

Optical unit and fiber protection

ITU-T G.978 describes tight and loose cable structures. In a tight structure, fiber elongation follows cable elongation more closely. In a loose structure, the fibers can move within the cable so that fiber strain remains lower until cable elongation reaches a defined level.

A GYTA33 loose-tube construction should not be presented as the standard architecture for every oceanic cable. A BYUOC-1 LW optical unit uses fibers and gel inside a stainless-steel tube, while the reviewed GYTA33 and GYFTY33 documents use PBT loose tubes or subunits around a central strength member.

Water pressure and longitudinal water penetration

Water blocking and hydrostatic-pressure resistance answer different questions.

  • A water-blocking compound, tape, or yarn limits water movement along the cable after a breach.
  • A hydrostatic-pressure test examines how the cable or optical unit performs under external pressure.
  • A seawater-resistant covering protects external materials, but it does not by itself prove a particular deployment depth.

A cross-section can confirm that water-blocking components exist. It cannot replace the applicable pressure and penetration test results.

Published article claim structure

Conductive path in a lightweight submarine cable

Some oceanic cable designs contain a conductive path for system functions. The BYUOC-1 LW structure supplied by FIBCONET includes a copper tube and PE insulation outside its inner armouring wires. This does not turn the product into a submarine power cable: its primary transmission line is optical fiber, and its electrical properties serve the submarine telecom cable design.

Strength members and armour

The strength system must support the cable during laying, recovery, repair, and operation. Four load terms appear in submarine cable specifications:

  • CBL — Cable Breaking Load: breaking load established for the cable design.
  • NTTS — Nominal Transient Tensile Strength: a temporary load limit associated with transient handling or recovery conditions.
  • NOTS — Nominal Operating Tensile Strength: a load level used for operating or repair-related handling.
  • NPTS — Nominal Permanent Tensile Strength: the permanent load condition after laying.

These values are not interchangeable. A specification that combines CBL and NTTS into one number removes a distinction needed for cable handling.

Submarine Cable Protection Types

ITU-T G.978 gives typical application depths for the five protection classes. These ranges overlap and serve as design references, not automatic model-selection rules.

ITU-T G.978 typical application depth table
Protection typeTypical protection roleTypical application depth in ITU-T G.978Route questions before selection
LWLightweight cable where no special external protection is requiredMore than 1,000 mIs the seabed free from significant external hazards? What are the laying and recovery loads?
LWPLightweight cable with added protection where a special hazard existsMore than 1,000 mIs there fish-bite, erosion, or another identified deep-water threat?
SAOne armour system for burial and protected operation in selected shallow-water areasMore than 20 m to 1,500 mWhat are the anchor, fishing, seabed, and burial conditions?
DATwo armour systems for selected shallow-water areas0 to 100 mDoes the route require more mechanical protection than an SA design provides?
RARoute-specific protection for rock exposure and high-risk shallow-water areas0 to 20 mWhat abrasion, shore-end, rock, and handling loads apply?

A deeper route does not automatically require heavier armour. Deep-ocean sections often have lower exposure to anchors and fishing equipment, while shore ends and continental-shelf sections may face more external aggression. Added armour also increases cable weight, diameter, handling loads, and jointing requirements.

How Route Conditions Change the Cable Structure

Deep-ocean route

Deep-ocean selection starts with the water-depth profile, cable weight in water, pressure resistance, laying tension, recovery method, system span, and optical design. Where no special external protection is required, an LW cable can reduce weight and handling load compared with an armoured shallow-water design.

The source specification for BYUOC-1 LW states a maximum laying depth of 8,000 m. That value applies to this model, not to every submarine cable sold on the same product page. A project still needs a route-specific review of depth, seabed, installation equipment, joint plan, optical budget, and terminal system.

Continental shelf and shallow water

Shallow water exposes the cable to anchors, fishing tools, vessel activity, seabed movement, and installation work. ITU-T G.978 therefore places SA, DA, and RA applications mainly within overlapping shallow-water ranges.

The armour level should follow a route risk assessment. A depth value alone does not establish whether the project needs burial, one armour layer, two armour layers, rock protection, or a protective conduit.

Landfall and shore end

A shore-end section may combine wave action, rock contact, human activity, trenching, ducts, and repeated access. The cable design must match both the environmental loads and the installation method. An engineer may also need a transition between offshore and land cable constructions.

River, lake, and coastal crossing

IEC 60794-3-30:2008 covers optical telecommunication cables for lakes, river crossings, and coastal applications. This scope is a better starting point for a GYTA33 or GYFTY33 route than a specification written for a complete repeatered oceanic system.

Compliance still has to be shown at model level. Citing the IEC family specification does not prove that a particular batch passed every required test.

Where FIBCONET’s Two Product Lines Fit

FIBCONET presents BYUOC-1 LW and GYTA33/GYFTY33 on one submarine optical cable product page. They address different route conditions and must keep separate specification columns.

BYUOC-1 LW for deep-water repeaterless routes

FIBCONET supplies BYUOC-1 LW sourced from its original manufacturer. The model is a lightweight, unrepeatered submarine optical cable for deep-water areas where laying, recovery, and operation do not require special external protection.

BYUOC-1 LW parameterSource-model specification
Nominal outer diameter13.0 mm
Fiber capacityUp to 32 fibers; a higher count requires redesign
Available fiber familiesG.652.D, G.654, G.655
Maximum laying depth8,000 m
CBL65 kN
NTTS50 kN
NOTS30 kN
NPTS20 kN
Minimum bending radius without tension1 m
Impact60 J
Crush resistance15 kN/100 mm
Conductor resistance at 4°C≤1.5 Ω/km
Insulation resistance≥10 GΩ·km
Operating temperature-10°C to +40°C
Handling/installation temperature-15°C to +45°C
Storage temperature-30°C to +60°C
Normal service-life statementAt least 25 years under the source specification

The source product description also refers to unrepeatered 100 Gb/s single-span applications exceeding 500 km. Cable construction alone does not establish transmission reach. Fiber selection, terminal equipment, amplification architecture, optical power budget, dispersion, repair margin, and acceptance criteria determine the system result.

GYTA33 and GYFTY33 for shallow-water protection

GYTA33 and GYFTY33 use steel-wire protection for underwater or coastal routes where mechanical loads drive the cable design. The reviewed supplier documents show that specifications vary by model.

Supplier-stated modelReviewed configurationMechanical specification
GYFTY33-24B1.324 × G.652.D fibers; PBT subunits; FRP central strength member; 24 × 1.0 mm steel wires; PE inner/outer sheathLong-term/short-term tensile: 3/10 kN; long-term/short-term crush: 2/5 kN per 10 cm; TDS states maximum applicable water depth below 250 m
GYTA33-144B1.3144 × G.652.D fibers; PBT loose tubes; steel-and-PE central member; 36 × 1.2 mm steel wires; PE inner/outer sheathLong-term/short-term tensile: 10/20 kN; long-term/short-term crush: 3/5 kN per 10 cm

These are supplier-stated model specifications, not independent batch-test results. The values cannot be merged into one “GYTA33 submarine cable” specification because fiber count, central member, wire arrangement, diameter, and load ratings change by model.

For adjacent land or outdoor armoured sections, FIBCONET also lists a stranded armoured fiber optic cable. The project designer should confirm whether the transition requires a submarine cable joint, land cable termination, or another interface.

Why the specifications must stay separate

One product page can present multiple cable options, but a combined maximum-value summary can create a false specification. BYUOC-1 LW has a standard maximum of 32 fibers and a source-model maximum laying depth of 8,000 m. A GYTA33 configuration may offer a higher fiber count while serving a much shallower, mechanically exposed route.

A buyer cannot combine the 8,000 m depth of BYUOC-1 LW with the fiber count of a GYTA33 configuration and treat the result as one available cable.

Source-model statements cited in the article

What to Put in a Submarine Cable RFQ

A usable RFQ should let the supplier map the route to a model, test plan, and system boundary.

  1. Route segments and total length: Separate deep water, continental shelf, shore end, river/lake crossing, and land sections.
  2. Water-depth profile: Give typical and maximum depth by route segment, not one project-wide number.
  3. Seabed conditions: Include silt, sand, rock, reef, abrasion, slope, currents, and free spans.
  4. External hazards: State vessel traffic, anchor zones, fishing gear, marine-life risk, and planned burial depth.
  5. Laying method: Identify trench burial, surface laying, conduit protection, suspension, ploughing, or jetting as applicable.
  6. Optical requirements: Specify fiber count, fiber type, wavelengths, span, capacity, terminal equipment, and system margin.
  7. Mechanical requirements: Define CBL, NTTS, NOTS, NPTS, crush, impact, bending, and handling conditions rather than asking for “high tensile strength.”
  8. System scope: State whether the supplier must cover cable only, joints, terminations, branching units, repeaters, power feeding, installation supervision, or acceptance testing.
  9. Evidence and compliance: Request the model TDS, cross-section, test methods, sample or batch identification, hydrostatic-pressure and water-penetration evidence, applicable standard editions, and project documentation.

How to judge the response

  • A tensile value should identify whether it is CBL, NTTS, NOTS, NPTS, or another model-specific rating.
  • A crush value should include the loaded length and the acceptance condition, including any allowed attenuation change.
  • Water-blocking materials do not substitute for water-penetration or hydrostatic-pressure test evidence.
  • A standard reference should identify the relevant document and scope. “IEC 60794 compliant” is too broad for a model-level acceptance decision.
  • A transmission-distance statement should include the system conditions that produce that reach.
  • A design-depth statement should remain tied to the cable model and qualification basis.

Selection Matrix

Route needFirst cable family to evaluateMain verification work
Deep sea with no identified special external hazardLW, including BYUOC-1 LW where its specification matches the systemDepth qualification, weight in water, hydrostatic pressure, CBL/NTTS/NOTS/NPTS, optical-system design
Deep water with fish-bite or erosion riskLWP or another qualified protected designHazard evidence, added protection, weight and handling impact
Continental shelf or selected shallow-water routeSA or project-specific armoured cableBurial, anchor/fishing exposure, armour design, installation and repair loads
High-risk shallow waterDA or route-specific heavy protectionArmour layers, seabed intervention, joints, bend and handling limits
Rock or shore-end exposureRA or another route-engineered designAbrasion, rock contact, shore-end protection and transition design
River, lake, or coastal crossingGYTA33/GYFTY33 or another qualified underwater cableModel-specific depth, tensile/crush, water testing, laying method and IEC 60794-3-30 project requirements

The matrix narrows the search. It does not replace cable engineering, route survey data, or the purchaser’s acceptance specification.

FAQ

What are the layers of a submarine fiber optic cable?

The layers depend on the system and protection class. A cable may include optical fibers, gel or another water-blocking system, a stainless-steel or loose tube, strength wires, a metallic moisture or conductive layer, insulation, armour, and an outer covering. Repeatered, repeaterless, lightweight, and armoured cables do not share one universal layer sequence.

How is submarine fiber cable different from submarine power cable?

A submarine fiber cable uses optical fibers as its transmission line for data. A submarine power cable uses metallic conductors and an electrical insulation system to transmit power. Both may contain steel-wire armour and polymer coverings. Composite submarine cables can contain power conductors and optical units in one construction.

Why are shallow-water cables armoured?

Shallow-water and shore-end routes can expose a cable to anchors, fishing equipment, rocks, abrasion, burial work, and vessel activity. Armour adds mechanical protection, but the required level depends on the route survey, laying method, burial plan, and recovery loads. Shallow water does not automatically mean that every route needs double armour.

What is the difference between LW, LWP, SA, DA, and RA submarine cables?

LW is a lightweight cable for routes that do not require special external protection. LWP adds protection for an identified hazard. SA and DA add one or two armour systems for selected shallow-water and burial conditions. RA addresses rock and high-risk shallow-water exposure. ITU-T G.978 gives typical depth ranges, but final selection depends on the complete route risk assessment.

Is GYTA33 the same as a transoceanic submarine cable?

No. GYTA33 is a steel-wire-armoured fiber cable construction used for model-specific underwater, river, lake, or coastal applications. A transoceanic submarine cable system may require a qualified oceanic cable, joints, repeaters or a repeaterless system design, branching units, terminations, power-feeding functions, and marine installation engineering. A GYTA33 model should be evaluated against its own TDS and project scope.

Can BYUOC-1 LW be installed at 8,000 metres?

The source-model specification states a maximum laying depth of 8,000 m for BYUOC-1 LW. This is a model-level design statement, not an automatic project approval. The supplier and system designer still need the route depth profile, installation loads, pressure-test basis, optical-system design, joints, terminal equipment, and acceptance requirements.

Can a 288-fiber count and an 8,000-metre depth be combined in one cable?

Those values belong to different product discussions and should not be combined. BYUOC-1 LW has a standard maximum of 32 fibers; a design above 32 fibers requires redesign. Higher fiber-count GYTA33 configurations address a different cable family and route range. Ask for one model-level specification covering both the required fiber count and deployment conditions.

Get A Quick Quote

We will respond within 12 hours, please pay attention to the email with the suffix “@fibconet.com”. 

Also, you can go to the Contact Page, which provides a more detailed form.