1. Design and Construction of Fiber Optic Cable

A fiber optic cable consists of a core and cladding layer designed for total internal reflection, which is critical for transmitting light effectively.

The core is usually coated with acrylate polymer or polyimide to protect it from environmental damage, though this coating does not affect the optical waveguide properties.

The fibers are then bundled and encased in a resin buffer layer or core tubes, with multiple protective sheathings added based on the application requirements.

For harsh environments, the fiber need heavy polymer jacket, known as tight buffer construction.

This type of cable is suitable for various applications, including breakout and distribution configurations.

It might be different due to their specific design features like the inclusion of strengthening members and buffer tubing.

2. Indoor vs. Outdoor Applications

For indoor use, fibers are typically housing within a lightweight plastic cover along with strength members like aramid yarns.

Each end of the cable could terminate specialized optical fiber connectors for easy connectivity to transmitting and receiving equipment.

Outdoor cables, however, require more robust construction.

They might employ loose-tube construction where the fiber is laid helically within semi-rigid tubes, allowing the cable to stretch without stretching the fiber itself.

This design helps protect the fiber from physical stress and temperature changes. Outdoor fibers may also be gel-filled or dry block to protect against moisture.

3. Capacity and Market Innovations

Remarkably, modern fiber optic cables can handle immense data capacities.

For instance, in 2012, NTT Japan demonstrated a cable that transferred 1 petabit per second over 50 kilometers. Today, cables can contain up to a thousand fibers, offering potential bandwidths in the terabytes per second.

Companies often “overbuild” their networks with excess dark fibers, which are unlit fibers that can be leased or sold to other providers, creating a strategic asset that can be monetized.

4. Reliability and Quality Standards

Fiber optic cables are wiliing to be incredibly strong but can be susceptible to damage from microscopic surface flaws.

Standards such as Telcordia GR-20 and GR-409 outline the reliability and quality requirements for outdoor and indoor fiber optic cables, ensuring they meet rigorous operational demands.

5. Fiber Optic Cable Abbreviations

  • OFC: Optical fiber, conductive
  • OFN: Optical fiber, nonconductive
  • OFCG: Optical fiber, conductive, general use
  • OFNG: Optical fiber, nonconductive, general use
  • OFCP: Optical fiber, conductive, plenum
  • OFNP: Optical fiber, nonconductive, plenum
  • OFCR: Optical fiber, conductive, riser
  • OFNR: Optical fiber, nonconductive, riser
  • OPGW: Optical fiber composite overhead ground wire
  • ADSS: All-Dielectric Self-Supporting
  • OSP: Fiber optic cable, outside plant
  • MDU: Fiber optics cable, multiple dwelling unit

6. Jacket and Fiber Materials

Jacket Material: The outer covering of a fiber optic cable, known as the jacket, is crucial for its durability and functionality.

Common materials include LSZH (Low Smoke Zero Halogen), PVC (Polyvinyl Chloride), Polyethylene, Polyurethane, Polybutylene Terephthalate, and Polyamide.

Each material is chosen based on the cable’s specific application needs, including mechanical robustness and resistance to chemicals and UV radiation.

Fiber Material: Optical fibers mainly use two materials: glass and plastic.

Plastic fibers are typically used for short-range applications and consumer electronics due to their flexibility and cost-effectiveness.

In contrast, glass fibers fit both medium-range (multi-mode) and long-range (single-mode) telecommunications due to their superior performance in signal transmission.

7. Color Coding and Fiber Optic Cable Types

Patch Cords

These are often color-coded to indicate the type of fiber used.

The strain relief boots and connector shells (like SC connectors) are also color-coded to denote various connection types.

ColorMeaning
Orangemulti-mode optical fiber
AquaOM3 or OM4 10 G laser-optimized 50/125 µm multi-mode optical fiber
Erika violetOM4 multi-mode optical fiber (some vendors)
Lime greenOM5 10 G wideband 50/125 µm multi-mode optical fiber
Greyoutdated color code for multi-mode optical fiber
Yellowsingle-mode optical fiber
BlueSometimes used to designate polarization-maintaining optical fiber
ColorMeaningComment
BluePhysical contact (PC), 0°mostly used for single mode fibers; some manufacturers use this for polarization-maintaining optical fiber.
GreenAngle polished (APC), 8°
BlackPhysical contact (PC), 0°
GreyPhysical contact (PC), 0°multimode fiber connectors
Beige
WhitePhysical contact (PC), 0°
RedHigh optical power. Sometimes used to connect external pump lasers or Raman pumps.

Remark: It is also possible that a small part of a connector is additionally color-coded, e.g. the lever of an E-2000 connector or a frame of an adapter.

This additional colour coding indicates the correct port for a patchcord, if one point many patchcords are installed at one point.

Multi-fiber cables

You can distinguish individual fibers by color-coded jackets or buffers, adhering to standards such as the EIA/TIA-598, which specifies optical fiber cable color coding.

EIA/TIA-598

This helps in identifying and organizing fibers within a cable, crucial for maintenance and troubleshooting.

The colour code used above resembles PE copper cables used in standard telephone wiring.

In the UK the colour codes for COF200 and 201 are different.

Each 12 fibre bundle or element within a Cable Optical Fibre 200/201 cable. Colors are as follows:

  • Blue
  • Orange
  • Green
  • Red
  • Grey
  • Yellow
  • Brown
  • Violet
  • Black
  • White
  • Pink
  • Turquoise

The cable has a central strength member normally made from fiberglass or plastic. There is also a copper conductor in external cables.

7. Technical Specifications

Propagation Speed and Delay

Fiber optic cables transmit data nearly at the speed of light in glass, approximately 200,000 kilometers per second. This translates to a latency of about 5 microseconds per kilometer, making fiber optics exceptionally suitable for high-speed data transmission over long distances.

Losses

Signal loss in fiber optics is measured in decibels (dB). Typical losses are about 3 dB per kilometer for multimode fibers and even lower for single-mode fibers. Connections and splices can add slight losses, which are critical to account for in network design to ensure signal integrity.

Reliability

Optical fibers are incredibly robust but can be susceptible to microscopic surface flaws from manufacturing, which can impact their long-term durability. Proper handling during installation is crucial to maintain the fiber’s strength and functionality.

Practical Applications

Fiber optic cables are extensively used in various settings, from undersea communications to intracity networks and internal building links.

The technology continuously evolves, pushing the boundaries of data transmission capabilities. Innovations like the cables demonstrated by NTT Japan, capable of transferring staggering amounts of data, underscore the potential of fiber optics in shaping the future of global communications.

8. Safety Considerations in Fiber Optics

Laser Safety: The invisible infrared light used in fiber optics poses a potential hazard, especially since the human blink reflex does not react to infrared exposure.

To protect against eye damage during inspection, especially when lenses or microscopes are used, safety filters or indirect viewing devices equipped with cameras are recommended.

These devices display the fiber end on a screen, reducing the risk of direct eye exposure.

Handling Precautions: Small glass fragments from cleaved fibers can be hazardous. It’s crucial to collect and dispose of these fragments properly to prevent injury.

9. Hybrid Cables for FTTA Applications

Hybrid optical and electrical cables are pivotal in Fiber To The Antenna (FTTA) applications, combining data transmission and power supply in one cable.

These cables are essential for outdoor wireless setups, powering antennas on poles, towers, or other structures.

According to Telcordia GR-3173, these cables include both optical fibers and electrical conductors under a common jacket, handling nominal voltages typically below 60 VDC or 108/120 VAC.

These versatile cables are also applicable in Distributed Antenna System (DAS) environments, requiring adherence to fire safety standards, electrical safety codes, and performance-related concerns.

10. The Role of Innerducts in Cable Installation

Innerducts are installed within existing underground conduit systems to facilitate the placement of optical cables, which generally have low tension limits.

They subdivide large conduit pathways into smaller, manageable channels.

Types of Innerducts: As per Telcordia GR-356, there are three primary innerduct types:

  • Smoothwall
  • Corrugated
  • Ribbed

Each type based on specific needs such as flexibility, strength, or low friction.

Moreover, multiduct configurations, where multiple individual innerducts are bundled or extruded together, allow for simultaneous cable installations.

Installation Methods: There are various ways to place Innerducts :

  1. Pre-installed during manufacturing.
  2. Pulled using mechanical assistance.
  3. Blown using high-volume air techniques.

These methods ensure that fiber optic cables are installed with minimal stress and risk, preserving their integrity and functionality.

If you are looking for a trusted fiber optic manufacturer, contact us now!

Get A Quick Quote

We will respond within 12 hours, please pay attention to the email with the suffix “@fibconet.com”. 

Also, you can go to the Contact Page, which provides a more detailed form.